PLANNING
GUIDE
DR30D, DR30DH, DR30DI, DR30DIH
Distinctive 30” Wide
Dual Fuel Range
Document # PG05-006
Revised 12/11/14 Page 2/6
Ranges equipped for installation in Canada:
■
Freestanding ranges used in Canada require
a factory installed 4-wire appliance cord and
NEMA 14-50P plug. Order model number
DR30D-C or DR30DH-C. The appliance cord is
66 inch (168 cm) long.
■
Do not modify the factory wiring. The plug is
designed to plug directly into a NEMA 14-50R
electrical receptacle installed by a licensed
electrician.
All other models:
The wiring needs to be long enough to allow the range to be pulled out for
service, while remaining connected (see following page).
The wiring connected to the range must:
■
Meet NEMA standards and have a minimum rating of 250 Volts @ 30
Amp.
■
Include a strain relief.
■
Be terminated by tinned leads, closed loop terminals or open ended
spade lugs with upturned ends.
■
Connect to a junction box or receptacle installed by a licensed
electrician.
Where local code permits, a 3 or 4 wire appliance cord may be used. It
must:
■
Be UL listed type SRD or SRDT.
■
Be equipped with a NEMA 14-50P 4-wire plug or, where local code
permits, a NEMA 10-50P 3-wire plug.
Electrical Specifications
Circuit Required
Total Connected Load
240 Vac, 60 Hz., 30 Amp.*
5.7 kW (23.8 Amp.)
■
The ratings above are for reference only - refer to the range's product
data label for exact specifications.
■
The correct voltage, frequency and amperage must be supplied to
the appliance from a separate, grounded, circuit that is protected by a
properly sized circuit breaker or time delay fuse. If a time-delay fuse is
utilized, fuse both sides of the line (L1 and L2).
* Two 120 Vac hot (L1 and L2), one neutral, one ground
The regulator inlet accommodates a 3/4” gas line. The range ships with a
1/2” to 3/4” adapter connected to the regulator.
Gas and Electrical Requirements
A
B
C
D
4 3/4”
(12.1 cm)
22 1/8”
(56.2 cm)
8 3/4”
(22.2 cm)
13 3/4”
(34.9 cm)
B
Gas
inlet
A
C
7/8” (2.2 cm) dia. electrical
connection hole in bottom*
D
Range electrical access,
cover removed
GAS AND ELECTRICAL DIMENSIONS
Gas Supply Pressure Requirements*
Gas Type
Manifold Pressure
Minimum Gas Supply
Pressure
Natural gas
5” water column
6” water column
LP
10” water column
11” water column
* Maximum input gas supply pressure for all models is 1/2 psi
7/8" to 1 1/8" dia. access hole
NEMA 14-50R
RECEPTACLE