4.19

See note 2

2 See Cabinet/Countertop Dimensions - Top View 

3 Not applicable for cabinets more than a horizontal 

distance of 10” (254mm) from the edge of the cooktop.

1 Vertical to combustible surface from cooktop grate level;

if installing an overhead vent hood, also check the hood

specifications for minimum required clearances. 

C

13” (330 mm) 

max.

3

Top of

finished

counter

18” (457 mm)

Min.

1, 3

30” (762 mm)

Min.

1

Cutout for 

utility access

Hood

Recommended

gas and electrical

service location,

consult local code

B

10” (254 mm) to

combustible side 

wall Min. both sides

1/2” (13 mm)

overhang,

both sides

1 1/2” (38 mm)

typical countertop

thickness

7 3/4” 

(197 mm)

36” (914 mm)

typical

Cooktop platform

1”  (25 mm) Min.

thickness

Model No.

B

C

DRT304S

30” (762 mm) 

30” (762 mm)* 

36” (914 mm)**

DRT366S

36” (914 mm)

36” (914mm)* 

42” (1067 mm)**

* Minimum   ** Recommended

Cabinet tolerances: +1/16”, -0 (+1.6 mm, -0) 

unless otherwise noted.

cABINEt/coUNtErtoP DImENSIoNS - FroNt VIEw

cABINEt/coUNtErtoP DImENSIoNS -

ISo VIEw

Continued. on following 

page...

Cabinet and Countertop Layout (Continued)

30” and 36” Wide, Distinctive Series

Slide-in Gas Cooktops

DRT304S, DRT366S

Document # PG04-003

Revised 06/22/09   Page 2/3

NOTE: 

Models DRT304S and DRT366S are not 

approved for installation with a raised vent.

Отзывы: