10
1. Before proceeding, turn off power to the circuit to which
the oven will be connected at the circuit breaker or fuse
box.
2. Position the oven directly in front of the cabinet cutout.
3. Feed the appliance conduit into the electrical junction
box and attach it using a UL approved strain relief.
4. Depending upon local codes, utilize one of three meth-
ods to connect the appliance to the electrical power:
◊
Connect to a four (4) wire electrical system
◊
Connect to a three (3) wire electrical system, where
local codes permit
◊
Connect to a three (3) wire electrical system with
external ground, according to local codes.
Connecting to a Four (4) Wire Electrical
System
1. Separate the wires coming out of the appliance conduit.
2. Connect the white wire from the appliance conduit to
the white (neutral) supply wire in the junction box.
3. Connect the black wire from the appliance conduit to
the black (L1) supply wire in the junction box.
4. Connect the red wire from the appliance conduit to the
red (L2) supply wire in the junction box.
5. Connect the green wire from the appliance conduit to
the green (ground) wire in the junction box.
Installation Instructions
Electrical Service Installation
WARNING
•
Wire the oven only in compliance with local ordinanc-
es.
•
If the electrical service provided does not meet the
product specifications, do not proceed with the instal-
lation. Call a licensed electrician to install the required
wiring.
•
To prevent an electric shock or fire hazard, turn off
power to the circuit at the circuit breaker or fuse box
prior to connecting the wiring to the oven.
•
Improper connection of the electrical wiring can cause
an electric shock hazard and damage the appliance.
Dacor is not responsible for damages resulting from
improper installation.
•
Connect the ground terminal (or lead) on the appliance
to a grounded, metallic, permanent wiring system or
grounding conductor.
•
Do not use an extension cord with this appliance.
Such use may result in fire, electric shock or other per-
sonal injury.
•
Do not install a fuse in the neutral or ground circuit. A
fuse in the neutral or ground circuit may result in an
electric shock hazard.
•
The appliance must be connected to the power supply
with copper wire only. The use of aluminum wire may
result in unsatisfactory connections.
•
Flexible armored or non-metallic, sheathed copper
cable (with grounding wire) should be used to connect
the appliance to the junction box. An UL-listed connec-
tor must be used to directly connect the cable to the
junction box.
IMPORtANt
Make sure that the conduit is long enough to allow the
oven to be pulled out for service without disconnecting it
from power.
Junction box
Four (4) Wire Junction Box Connection
Cable from circuit breaker
panel or fuse box
Conduit to
wall oven
RED
WHITE
BLACK
GREEN
RED
WHITE
BLACK
GREEN
Wire nut