background image

7

Installation Specifications

Cabinet Cutout Dimensions, cont.

All tolerances: +1/16 (+1.6 mm), -0, unless otherwise stated.

Countertop Flush-Cutout Dimensions—for 

Down-Draft Vent (top view)

Width Dimensions

Model

A

B

DYTT305

30 1/8” (76.5 cm)

28 3/4” (73.0 cm)

DYTT365

36 1/8” (91.8 cm)

34 3/4” (88.3 cm)

DYTT Cooktop w/Downdraft Cutout Dimensions

Model

Configuration

(C) Cooktop

Cutout Width

(D) Downdraft

Cutout Width

(E) Total

Cutout Width

(F) Downdraft

Cutout Depth

(G) Min. Rear

Counter Overhang

DYTT305 cooktop w/

ERV3015/PRV30

28 3/4” (73.0 cm)

27 3/4” (70.5 cm)

22 1/2” (57.2 cm)

2 3/4” (7.0 cm)

3/8” (1.0 cm)

DYTT365 cooktop w/

ERV3615/PRV36

34 3/4” (88.3 cm)

33 3/4” (85.7 cm)

DYTT305 cooktop w/

RV30 downdraft

28 3/4” (73.0 cm)

27 3/4” (70.5 cm)

22 1/4” (56.5 cm)

2 1/2” (6.4 cm)

5/8” (1.6 cm)

DYTT365 cooktop w/

RV36 downdraft

34 3/4” (88.3 cm)

33 3/4” (85.7 cm)

Countertop Inset-Cutout Dimensions

 IMPORTANT (Inset Cutout)

See the previous page for minimum clearances to com-

bustibles and overhead cabinets.

 

IMPORTANT (Flush Cutout—for Down-Draft Vent)

•  See the previous page for minimum clearances to com-

bustibles and overhead cabinets.

•  Install only the downdraft models specified in the 

DYTT 

Cooktop w/Downdraft Cutout Dimensions

 table 

(below).

•  If installing the cooktop with a downdraft flush with 

the countertop, see the 

Countertop Inset-Cutout 

Dimensions

 section (this page). 

•  The countertop inset for the downdraft must be lower to 

accommodate the downdraft’s top cap, which extends 

the height of the downdraft. (See the downdraft’s instal-

lation instructions to determine the exact dimensions.)

•  Additional sealing is required between the cooktop 

chassis and the downdraft due to the difference in the 

required inset depth.

Содержание Discovery DYTT365N

Страница 1: ...Installation Instructions Discovery Touch Control Induction Cooktop Models DYTT305N and DYTT365N Part No 109374 Rev A...

Страница 2: ...efore you begin the installation process Leave these installation instructions with the customer Customer Keep these installation instructions for future reference and the local electrical inspector s...

Страница 3: ...sis Doing so may cause a fire hazard During after use do not touch or let clothing or flammable materials touch the cooktop until it has cooled sufficiently Do not let anyone use the cooktop without k...

Страница 4: ...luding above and below the cooktop Do not hang flammable or heat sensitive objects over the cooktop If the cooktop is near a window do not use window treatments that could blow over the cooktop and cr...

Страница 5: ...be accessible when the cooktop is in place Location Requirements Dacor recommends installing a non combustible material on the wall behind the cooktop To avoid a fire hazard do not install the cooktop...

Страница 6: ...installing a range hood above the cooktop The hood should cover the cooktop entire surface and proj ect at least 5 inches beyond the bottom of any overhead cabinets Miscellaneous Installation This sec...

Страница 7: ...face Cooking surface overhangs the top of the chassis by 3 4 1 9 cm in front back and on both sides Appliance Dimensions All tolerances 1 16 1 6 mm unless otherwise stated This section contains pertin...

Страница 8: ...tion 3 does not apply 4 1 1 8 2 9 cm min to combustible surface at rear 3 4 1 9 cm min to non combustible surface at rear 5 Ensure internal space allows proper under cabinet ventilation for cooktop ch...

Страница 9: ...5 8 1 6 cm DYTT365 cooktop w RV36 downdraft 34 3 4 88 3 cm 33 3 4 85 7 cm Countertop Inset Cutout Dimensions IMPORTANT Inset Cutout See the previous page for minimum clearances to com bustibles and ov...

Страница 10: ...d 2 Feed the appliance conduit into the junction box and attach it using a UL certified strain relief 3 According to local codes use one of the two methods shown on the next page to connect the applia...

Страница 11: ...wire to a grounded cold water pipe use a separate copper grounding wire 10 min and a clamp with an external grounding screw The grounded cold water pipe must have metal con tinuity to an electrical gr...

Страница 12: ...button The cook zone ON indicator goes out the cook zone is turned off WARNING If the cook zone HOT indicator has appeared it will stay on until the cook zone is safe to touch without causing a burn i...

Страница 13: ...11 Wiring Diagrams...

Страница 14: ...12 Wiring Diagrams...

Страница 15: ...13 Notes...

Страница 16: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com...