 WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE: 

22. 

SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray, then turn off the burner. BE CAREFUL 

a. 

TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE 

DEPARTMENT.
NEVER PICK UP A FLAMING PAN - you may be burned.

b. 

DO NOT USE WATER, including wet dish cloths or towels - a violent steam explosion may result.

c. 

Use a fire extinguisher ONLY if:

d. 

You have a Class ABC extinguisher, and you already know how to operate it.

• 

The fire is small and contained in the area where it started.

• 

The fire department is being called.

• 

You can fight the fire with your back to an exit.

• 

p

roduCT

 s

peCifiCaTions

G

eneral

 S

pecificationS

ALL MODELS

Blower

600 CFM (1200 for units with 2 

blowers) with electronic speed control

Blower Speeds

4

Lights

12 Vac, 20 W halogen

Filters

Baffle type, dishwasher safe

Exhaust

8-inch

Finish

430 stainless steel

Voltage

120 Vac, 60 Hz (see below for current 

rating)

Circuit 

Requirement

120 Vac, 15 Amp grounded, dedicated 

circuit, minimum

MODEL SPECIFIC

SPECIFICATION

MODEL

Blowers

Lights

Filters

Maximum 

Current Draw

DHI361

1

4

1

3.75 A

DHI421

1

4

1

3.75 A

DHI482

2

4

2

6.75 A

DHI542

2

6

2

7.10 A

DHI602

2

6

3

7.10 A

D

imenSionS

* 18” 1/4 on models DHI482, DHI542 and DHI602
** 30” on models DHI482, DHI542 and DHI602

IMPORTANT:

 The minimum installed distance from the 

hood to the cooktop surface must be no less than 30 

inches. The minimum specified distance may be higher 

for the particular range or cooktop in use. Check the 

manufacturers specifications for the cooktop or range. 

36” (91.4 cm) - 42” (106.7 cm)

48” (121.9 cm) - 54” 137.2 cm)

60” (152.4 cm)

  25 5/8”

(65.1 cm)**

    15 ¾” (40.0 cm)

    Chimney

 12 9/16” (31.9 cm)

   12 ½”  (31.8 cm)

   15 ½”  (39.4 cm)*

 28” (71.1 cm) to 36” (91.4 cm)

Tolerances: +1/16”, -0 (+1.6 mm, -0),  

unless otherwise stated

Содержание DHI361

Страница 1: ...Installation Instructions Millennia Island Ceiling Mount Range Hoods For use with models DHI361 DHI421 DHI482 DHI542 DHI602 Part No 101744 Rev B...

Страница 2: ...r s use If you have questions or problems with installation contact your Dacor dealer or the Dacor Customer Service Team Dacor Customer Service Team Phone 800 793 0093 Web site www Dacor com Important...

Страница 3: ...telephone in your building From a neighbor s phone immediately call the gas supplier Follow the gas supplier s instructions If you cannot contact the gas supplier call the fire department IMPORTANT Do...

Страница 4: ...or drilling into the wall or ceiling do not damage electrical wiring and other hidden utilities 9 The installer must show the customer the location of the fuse or junction box so that the customer kn...

Страница 5: ...ers with electronic speed control Blower Speeds 4 Lights 12 Vac 20 W halogen Filters Baffle type dishwasher safe Exhaust 8 inch Finish 430 stainless steel Voltage 120 Vac 60 Hz see below for current r...

Страница 6: ...ontact the dealer immediately Do not install a damaged or incomplete appliance Hood assembly with filter s Chimney assembly 2 piece Mounting bracket Blower exhaust cowling 2 blower units only Framewor...

Страница 7: ...Electrical Power Supply Electrical Specifications It is the owner s responsibility to ensure that the electrical connection of this appliance is performed by a qualified electrician The electrical in...

Страница 8: ...e Use sheet metal screws as require to support the duct weight To prevent back drafts a damper at the duct outlet may also be required Make sure duct work does not interfere with floor joists or wall...

Страница 9: ...tion Locate the mounting bracket and position it against the 1 ceiling at the previously determined mounting location see page 5 Using a pencil mark the four mounting hole locations 2 on the ceiling D...

Страница 10: ...t properly turn it 180 so that the cut outs line up Make sure all wiring is tucked inside the framework piece and are not pinched Use eight provided lock washers and nuts to secure the 8 bottom framew...

Страница 11: ...They protect the telescoping pieces from scratching during installation Carefully slide both sections together so that only the 15 vents on the top section show Hold the chimney vertically with the v...

Страница 12: ...t inside framework Hanging the Range Hood warning To prevent personal injury do not rely on the mounting springs to hold the hood assembly in place on the ceiling Once the hood is hooked in place IMME...

Страница 13: ...inside the chimney Connect the white wire from the hood to the neutral 1 white power supply wire Connect the black wire from the hood to the hot black 2 power supply wire Connect the green and yellow...

Страница 14: ...anty been activated on line or the warranty card filled out completely and mailed Verifying Proper Operation Turn on power at the junction or fuse box 1 If the control panel is not lit remove the filt...

Страница 15: ......

Страница 16: ...Dacor 1440 Bridge Gate Drive Diamond Bar CA 91765 Tel 800 793 0093 FAX 626 403 3130 www Dacor com...

Отзывы: