9
Installation Instructions
3. Connect the hood wiring to an electrical junction box on a dedicated circuit. See page 4 for specifications. Connect
it according to one of the wiring diagrams below.
GREEN
GREEN
WHITE
WHITE
BLACK
BLACK
3 wire connection to Junction Box
To house circuit breaker
panel or fuse box
Junction
box
Wire nut,
3 places
wArning
• Do not ground the circuit to a gas line or hot water
pipe.
• Water lines that are insulated must be jumped to
assure continuity to ground. See below.
insulated pipe Jumper
(if necessary)
GREEN
WHITE
WHITE
BLACK
BLACK
GREEN
grounding the hood wiring using
an external cold water pipe
UL/CSA approved
NEMA strain relief
UL/CSA approved
NEMA strain relief
Fasten clamp
tightly on pipe
Separate No. 10 (minimum)
copper ground wire
To house circuit breaker
panel or fuse box
To range
hood
To range
hood
Wire nut,
3 places
Junction
box
Meter
Clamps
Bare metal
No. 4 copper
wire