background image

Содержание DDWF24S

Страница 1: ...Installation Instructions 24 Inch Built in Dishwasher Model DDWF24S Part No 106811 Rev D ...

Страница 2: ...n instructions with the customer Customer Keep these installation instructions for future reference and the local electrical inspector s use If You Need Help If you have questions or problems with installation contact your Dacor dealer or the Dacor Customer Service Team For repairs to Dacor appliances under warranty call the Dacor Distinctive Service line Whenever you call have the model and seria...

Страница 3: ...vere personal injury or death I 1_ CAUTION I Hazards or unsafe practices thatCOULD result in m nor persona njury or pr0perty damagel _ DANGER I To avoid the p0ssibility of exPloSion o fire don0t store o use combustiblel flammable or explosive VaP0rs I and liquids such as gasoline inside or in the vicinity of this or any other appliance Do not store flammable or explosive materials in adjacent cabi...

Страница 4: ...r unless sPecifically recom mended n the literature accompanying it A qualified service technician should perform all 0the_service Contact the nearest Dacor auth0rized service representative for examination repair or adjustment WARNING Do not tamper with the controls This appliance is designed for installation by more than one person To avoid personal injury do not attempt to move or lift the dish...

Страница 5: ... 4 cm _ Depth with door closed 23 3 4 60 3 cm _l i __ Drain hose _ _ _ iJ Side I D e P_ sd mebsa _s _u it F 5 1 4 13 5 cm to LI I _ 7 1 4 18 5 cm _ 1_ 2 50 0 cm 23 1 2 59 7 cm to front panel trim edge Do not modify Drain hose Back 54 137 cm long I _ I Power cord Watersupplyline _ __ it t 60 1520m long __ ___ _ 3 _ J_ j _ _ 1 cm 70 cm Utility Connection Dimensions _mCD_ 3 ...

Страница 6: ...ou are in doubt whether the appliance is properly grounded Do not modify the plug prov ded wth the appliance if it will not fit the outlet have a proper outlet installed by a qualified electrician Do not use an extension cord for this appliance Grounding Instructions for a Permanently Connected Appliance This unit must be grounded to operate properly It must be connected to a grounded metal perman...

Страница 7: ...e edges of the opening shall be smooth and rounded If the partition is metal the edges of the opening shall be covered with an edge protector Call Dacor for the part number of an approved edge protector The opening A through the partition between the drain connection and the dishwasher cutout must be higher than the disposer or waste tee connection see page 6 and lower than 30 76 cm If the partiti...

Страница 8: ... a cone shaped connector on the end that is ready to be cut to the desired drain connection size Only a clamp not provided is required It fits drain connections with an internal diameter of 1 2 5 8 23 32 and 7 8 inches 1 3 1 6 1 8 and 2 2 cm You must install an air gap in the drain system if required by local codes Plan for the air gap in the sink or countertop area adjacent to the dishwasher A se...

Страница 9: ... Inspect the unit for shipping damage including cosmetic damage If any item is missing or damaged please contact the dealer immediately Do not install a damaged or incomplete appliance Included la ra II Toe kick Mounting hardware 2 screws 2 spacers 2 plastic plugs Plastic feet 3 O ring comes attached to the water line Product literature Tools required for installation l Level Crescent wrench I1_ W...

Страница 10: ...ides of the dishwasher If adjustment is necessary try making small adjustments on only one side first 1 Be sure the door is closed 2 Grab the front end of the spring and pull it up and forward to release it from the forward mount Door spring Side of Dishwasher To make small tension adjustments to the spring hold the back end of the spring with one hand and turn the front part one or more times Tur...

Страница 11: ...the front legs as necessary 5 Adjust the rear leg until the floor of the dishwasher is level front to back 6 Tighten the rear retaining nut but leave the front retaining nuts loose to allow for final leveling after the unit is pushed into place Connecting the Electric Cable Permanently Connected Appliance Only If the cord is not long enough or if a hard wire installation is needed follow the steps...

Страница 12: ... Permanent Wiring Connection 8 Re install the electrical access panel and the toe kick brackets Installing the Unit in the Cabinet 1 Position the dishwasher in front of the cabinet opening 2 Before sliding the unit into the cutout make sure the drain hose water supply line and power cable are positioned in the utility cutouts as shown below Make sure each is routed to the side it will be connected...

Страница 13: ...ser connection or hose extension 3 Connect the drain hose to the air gap or directly to the waste tee or disposer above the sink trap as shown in one of the examples on page 6 4 Tighten the holding clamp 5 For installations with an air gap make sure that the drain line between the air gap and the waste tee or disposer is in place and that it is clamped tightly on both ends 6 To ensure proper opera...

Страница 14: ...the appliance yourself If you need service be sure to have the model and serial numbers available when you call See the inside cover for location Dacor is not responsible for the cost of correcting problems caused by a faulty installation Final Leveling 1 Check to make sure that adjacent drawers and cupboards can be opened when the dishwasher door is open Reposition the dishwasher if necessary 2 C...

Страница 15: ...aterial to the back of the toe kick Insulation t Toe kick 3 The anti tip brackets may be secured either through the top or the sides Installations with a hard material like granite may require attachment through the sides 4 When installing the screws place the included spacer over the screw Insert the screws into the holes in the anti tip brackets through the access holes in the top or sides of th...

Страница 16: ...phasized Has the unit been inspected for cosmetic damage Has all packaging and literature been removed from the dishwasher Is the power cable connected to a three prong grounded electrical outlet or grounded junction box that meets the electrical specifications Has the O ring been installed on the water supply line Have the water supply line and the drain hose been properly installed according to ...

Страница 17: ...clmcar 15 ...

Страница 18: ...16 _mcar ...

Страница 19: ...ItemNo 8088919Rev 04 The LifeoftheKitchen Dacor 600 Anton Blvd Suite 1000 Costa Mesa CA 92626 Phone 800 793 0093 Fax 626 403 3130 www Dacor com ...

Отзывы: