background image

10

Installation Instructions

Installation Checklist

 WARNING

• 

To ensure a safe and proper installation, the follow-

ing checklist should be completed by the installer to 

ensure that no part of the installation has been over-

looked.

• 

Proper installation is the responsibility of the home-

owner. The importance of proper installation of your 

Dacor cooktop cannot be overemphasized.

 

Is the electrical outlet for the cooktop grounded and 

located according to these instructions and in accor-

dance with all applicable electrical codes? See page 

4.

 

Is the gas service for the cooktop located and installed 

according to these instructions and in accordance with 

all applicable codes? See page 4.

 

Has the gas supply inlet pressure been measured to 

ensure that it does not exceed the maximums stated in 

these instructions? See page 4.

 

Is the cooktop secured using the provided hold-down 

brackets? See page 7.

 

Is the cooktop connected to the gas supply according 

to these instructions and in accordance with all appli-

cable codes? Did the installer check the gas supply for 

leaks? See page 7.

 

Are the burners and grates properly installed according 

to these instructions? See page 8.

 

Has proper operation been verified?

 

Has the warranty been activated on-line or the warranty 

card filled out completely and mailed?

Содержание DCT365/NG

Страница 1: ...Installation Instructions Distinctive Series Cooktop Model DCT365 Part No 106927 Rev A...

Страница 2: ...instructions for future reference and the local electrical inspector s use NOTE Dacor is not responsible for service required to correct a faulty installation 2010 Dacor all rights reserved If You Ne...

Страница 3: ...rning TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVEN...

Страница 4: ...p Do not climb on any part of the appliance warning General Safety Precautions To reduce the risk of fire electric shock serious injury or death when using this appliance follow basic safety precautio...

Страница 5: ...ooktop Top panel overhang Gas inlet protudes 1 3 cm from bottom 1 4 4 cm 36 91 4 cm 2 5 1 cm countertop to cooking surface 21 53 3 cm 4 10 2 cm chassis height Product Dimensions Utility Locations Util...

Страница 6: ...bel See the Chassis Bottom Diagram for label location Units equipped for high altitude operation have an H at the end of the model number listed on the product data label Check your local building cod...

Страница 7: ...gas and electrical service behind it The installation must allow for the following Access to the gas shut off valve and regulator when the unit is installed Access to the electrical outlet when the c...

Страница 8: ...stible side wall above countertop both sides F Vertical combustible surface Rear wall 1 5 8 min 4 1 cm Installation Specifications Cutout Dimensions Countertop Cutout Dimensions All tolerances 1 16 0...

Страница 9: ...flon tape or plumber s putty on flexible gas line connections Test the gas lines for leaks as instructed before use Do not use a flame to check for leaks The maximum gas supply pressure to the regulat...

Страница 10: ...tch the burner parts to the correct size and type of burner When installing the burner components make sure they are centered Twist each piece back and forth slightly until it drops completely into pl...

Страница 11: ...or at least 5 minutes to allow any gas to dissipate then repeat the test Once the burner lights rotate the control knob counterclockwise from HIGH to LOW to adjust the flame height progressively On th...

Страница 12: ...as service for the cooktop located and installed according to these instructions and in accordance with all applicable codes See page 4 Has the gas supply inlet pressure been measured to ensure that i...

Страница 13: ...Wiring Diagram DCT365 Verify proper operation after servicing 120 Vac 60 Hz power supply warning Label all wires prior to dis connection when servicing controls Wiring errors can cause improper and da...

Страница 14: ...12 Notes...

Страница 15: ......

Страница 16: ...Dacor 600 Anton Blvd Suite 1000 Costa Mesa CA 92626 Phone 800 793 0093 Fax 626 403 3130 www Dacor com...