background image

PLANNING

GUIDE

Web: http://www.Dacor.com

Corporate Phone: 800-793-0093

Specifications are subject to change without notice.

See installation instructions for additional details.

5.7

60” Wide,

Epicure

®

 Range

ERD60

1/2

Revised

06/25/08

27" (686mm) 

26" (660mm) 

28 1/2" (724mm) 

37” 

(940mm) 

to 

35 3/4" 

(908mm) 

Finished Side Panel 

24 3/8" (619mm) 

Rear of Control Panel/Oven Door 

Face of Control Panel/Oven Door 

Front Edge of Bullnose 

Handle 

6” (152mm) Backguard 

When Backguard and 

Side Panels are  

removed, the overall  

depth  decreases  

by 1" (25mm) 

Accessory 3” (76mm) Side Panels 

(Dacor Model No. AESP03) 

1 9/16" 

(40mm) 

ERD/EGR30, ERD60 ovERALL DImENsIoNs 

sIDE vIEW

NOTES:

1.   Utilities may be located in the lower left corner of 

the adjacent right cabinet. (Recommended)

2.  Contact your local building department to verify 

compliance with local code interpretation.

3.   Two electrical circuits and gas supplies required.

 waRNiNg

Observe all governing codes and ordinances during 

◊ 

planning and installation.  Contact your local building 

department for further information.
This appliance must be installed in accordance with the 

◊ 

accompanying installation instructions.

Dacor

®

Model No.

Dedicated Circuit*

Required

Total

Connected

Load

gas 

Type

Manifold

Pressure

Min. gas Supply

Pressure

ERD60

240 Vac, 4-wire, 60 Hz, 

30 Amp (Breaker) X2

4.1 kW

(21Amp) X2

Natural

5” Water Column

6” Water Column

ERD60LP

Liquid 

Propane

10” Water Column

11” Water Column

ELEctRIcAL AND GAs sUPPLy REqUIREmENts

*Two separate dedicated circuits are required, one for left and one for the right side of the range.

REAR vIEW

Power Cords

60" (1524mm) 

Factory installed 3/4” regulators 

(1/2” supply ok)

6" (152mm) 

Backguard 

Отзывы: