OWNER'S 

MANUAL 

 

New Versa 

Chair 

English 

Содержание New Versa

Страница 1: ...OWNER S MANUAL New Versa Chair English...

Страница 2: ...2 897 114 Rod Abr o Assed Km 53 450m Cx Postal 782 CEP 14097 500 Ribeir o Preto S P Brazil Telephone 55 16 3512 1212 Technical manager Daniel R de Camargo CREA SP 5062199650 ANVISA Registration No 101...

Страница 3: ...1 Precautions and warnings during equipment installation 21 Recommendations for equipment maintenance 22 Precautions and warnings during equipment use 22 Precautions and warnings after equipment use 2...

Страница 4: ...he best in class in the world This manual gives you an overview of your equipment It describes important details that can guide you in its correct use as well as in solving small problems that may eve...

Страница 5: ...d patient entry easier for patients with mobility limitations Trendelenburg position automatic position with the chair movement Large tray space to accommodate all instruments The equipment was constr...

Страница 6: ...all optional items your equipment will consist only of the items chosen during your purchase option 01 02 03 05 04 08 06 07 01 Headrest 02 Chest backrest 03 Fixed arms 04 Seat 05 Footrest 06 Joystick...

Страница 7: ...tion against electric shock Type B Applied Part Mode of operation Continuous with intermittent charge 1min work and 4 min rest Protection against harmful water penetration IP00 The entire chair for ex...

Страница 8: ...by means of 2 fuses and internal overcurrent protection for equipment attached to the chair Electronic System The chair has an integrated electronic system with low voltage which allows total interfa...

Страница 9: ...11 Group 1 New Versa Chair uses RF energy only for its internal function However its RF emissions are very low and are not likely to cause any Interference with nearby electronic equipment RF Emissio...

Страница 10: ...s to land It is recommended that the quality of the energy supply be that of a typical hospital or commercial environment Voltage drops short interruptions and voltage variations in the power supply i...

Страница 11: ...through on site electromagnetic inspection be less than the level of compliance in each frequency rangeb Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At...

Страница 12: ...ng to the transmitter frequency 150 kHz up to 80 MHz d 1 2 p 80 kHz up to 800 MHz d 1 2 p 800 kHz up to 2 5 GHz d 2 3 p 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23...

Страница 13: ...13 TECHNICAL SPECIFICATIONS Dimensions mm 13...

Страница 14: ...t It indicates safety instructions for product operation Failure to follow it can result in serious danger to the patient Grounding at various points on the equipment indicates the condition of being...

Страница 15: ...For your safety the Chair leaves the factory positioned at 220V so make sure that your network is compatible before connecting it if it is 127V request the presence of an authorized Dabi Atlante tech...

Страница 16: ...akes the added weight not to compromise the set stability How to fix the chair base to the floor The base of the chair must be fixed to the floor using S 10 Plastic Bushing Hexagonal Wood Steel Screw...

Страница 17: ...that stays on off when the office is on off If the Chair is in any movement seat and or back working position and at this moment there is a power outage or accidental disconnection of the main switch...

Страница 18: ...te the joystick laterally to the left right to raise lower the backrest To stop the movement just stop activating the joystick Longitudinal movement of the headrest Optional Rotate the handle located...

Страница 19: ...and turn the handle clockwise to lock the mechanism Make sure that the assembly has been sufficiently tightened to prevent movement during use Multiarticulated Headrest Press and hold the pneumatic l...

Страница 20: ...function as the Chair pedal 1 Chip Blower 2 Back to Zero 3 Micro Motor Memory 4 Reflector 5 Dry tip actuation pushing the pedal sliding lever to the left 6 Counterclockwise implant removal by pushing...

Страница 21: ...ental conditions in normal use situations The equipment was designed not to be sensitive to interference such as magnetic fields external electrical influences electrostatic discharges pressure or pre...

Страница 22: ...s cause interference with other equipment Do not use this equipment in conjunction with other devices that are very sensitive to interference or with devices that create high electromagnetic disturban...

Страница 23: ...nt has any abnormality check if the problem is related to any item listed in the topic unforeseen events failures causes and solutions If it is not possible to solve the problem turn off the equipment...

Страница 24: ...equipment must not be disposed of as household waste Precautions to be taken against foreseeable or unusual risks related to equipment deactivation and abandonment In order to avoid environmental con...

Страница 25: ...te Sodium Nitrite Essence Deodorized Propane Butane Demineralized water For more information on cleaning procedures refer to the manufacturer s instructions on the product WARNING This product can als...

Страница 26: ...it is not possible to solve the problem turn off the equipment and request Dabi Atlante technical assistance UNFORESEEN EVENTS TROUBLESHOOTING If you encounter any problem in the operation follow the...

Страница 27: ...isit and the travel expenses of the technician except when the customer sends the equipment to carry out maintenance within the technical assistance establishment Consumer Protection Code art 50 sole...