12. TYPES OF ALARM

Alarm Code

Alarm Symbol

Alarm Description

e0 - e16;  e21

Internal Error      

e17 - e19

Short Circuit      

e20

Voltage Error     

e22 - e31

Internal Error          

e32 - e35

Electronic system excess temperature

e37

Low voltage      

e38

High voltage       

e39 - e40

Pump blocked       

e43; e44; e45; e54

Pressure Sensor

e46

Pump Disconnected

e42

Dry operation

e56

Motor excess temperature (motor 
protector trips)

e57

Frequency of PWM external signal less 

than 100 Hz

e58

Frequency of PWM external signal 

greater than 5 kHz

INFORMATION
Frequently asked questions (faq) on the ecodesign directive 2009/125/ec establishing 

a framework for the setting of ecodesign requirements for energy-related products and 

its implementing regulations: 

http://ec.europa.eu/enterprise/policies/sustainable-

business/documents/eco-design/guidance/files/20110429_faq_en.pdf

Guidelines accompanying commission regulations implementing the ecodesign directive: 

http://ec.europa.eu/energy/efficiency/ecodesign/legislation_en.htm - see “circula-

tors”.

Table 7: List of alarms

13. ERROR CONDITION AND RESET

Display 

indication

Description

Reset

e0 – e16

Internal  error   -

Switch off system power.

-

Wait for the warning lights on the control panel 

to go off, then power the system again.

-

If the error persists, change the circulator.

e37

Low mains 

voltage 

(LP)

-

Switch off system power.

-

Wait for the warning lights on the control panel 

to go off, then power the system again.

-

Check that the mains voltage is correct, if nec

-

essary reset it at the plate values

e38

High mains 

voltage 

(HP)

-

Switch off system power.

-

Wait for the warning lights on the control panel 

to go off, then power the system again.

-

Check that the mains voltage is correct, if nec

-

essary reset it at the plate values.

e32-e35

Critical 

overheat-

ing of

electronic 

parts

-

Switch off system power.

-

Wait for the warning lights on the control panel 

to go off.

- Check that the system ventilation ducts are

not blocked and that the environment temper-
ature of the premises is correct.

e43-e45; 

e54

Sensor sig

-

nal absent

- Check sensor connection.
-

If the sensor is faulty, replace it.

e39-e40

Protection 

against 

overcurrent

- Check that the circulator turns freely.
- Check that any antifreeze added does not ex-

ceed the maximum percentage of 30%.

e21-e30

Voltage 

Error

-

Switch off system power.

-

Wait for the warning lights on the control panel 

to go off, then power the system again.

-

Check that the mains voltage is correct, if nec

-

essary reset it at the plate values.

e31

Twin com-

munication

absent

- Check that the twin communication cable is

intact.

- Check that both circulators are powered.

e42

Dry oper

-

ation

-

Put the system under pressure.

Содержание EVOPLUS B 120/220.32 M

Страница 1: ...INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE V3 0...

Страница 2: ...40 50 M D 60 240 50 M D 80 240 50 M D 100 280 50 M D 120 280 50 M D 150 280 50 M D 180 280 50 M B 40 340 65 M B 60 340 65 M B 80 340 65 M B 100 340 65 M B 120 340 65 M B 150 340 65 M B 40 340 65 SAN M...

Страница 3: ...1A ONLY FOR HEATING Figure 1 Assembly position 1 2 4 3 Torque 19 20 Nm C D Figure 2 Instructions for motor head assembly 3 B 1 2 A Figure 10 Control panel Figure 3 Installation on horizontal pipes...

Страница 4: ...B 180 280 50 SAN M 18 0 37 02 D 180 280 50 M 18 0 66 64 B 40 340 65 M B 40 340 65 SAN M 4 0 27 90 D 40 340 65 M 4 0 50 22 B 60 340 65 M B 60 340 65 SAN M 6 0 34 47 D 60 340 65 M 6 0 62 05 B 80 340 65...

Страница 5: ...8 EVOPLUS B 80 450 100 M 0 18 EVOPLUS B 100 450 100 M 0 19 EVOPLUS B 120 450 100 M 0 19 EVOPLUS D 120 220 32 M 0 22 EVOPLUS D 40 220 40 M 0 23 EVOPLUS D 60 220 40 M 0 23 EVOPLUS D 80 220 40 M 0 23 EVO...

Страница 6: ......

Страница 7: ......

Страница 8: ...9 Control Panel 18 9 1 Graphic Display 18 9 2 Navigation Buttons 18 9 3 Warning Lights 18 10 Menus 18 11 Factory settings 20 12 TypeS of Alarm 21 13 Error Condition And Reset 21 INDEX OF FIGURES Figu...

Страница 9: ...jecting the products to needless impacts and collisions To lift and transport the circulator use lifting devices with the aid of the pallet supplied with it if contemplated 4 3 Weight The adhesive pla...

Страница 10: ...it has been correctly assembled the motor assembly rests completely on the pump body Incorrect assembly may damage the impeller causing a typical rubbing noise when the circulator starts The electron...

Страница 11: ...e pump in re mote mode 13 IN2 10 Clean contact Economy If is activated from the control panel see par 12 Page 5 0 of the EVO PLUS menu it will be possible to active the set point reduction function in...

Страница 12: ...d 5 COM 6 NO The outputs OUT1 and OUT2 are available on the pull out 6 pole terminal board as spec ified in Table 4 which also shows the type of contact NC Normally Closed COM Common NO Normally Open...

Страница 13: ...gh temperature and pressure the fluid in the sys tem may also be in the form of steam DANGER OF SCALDING It is dangerous to touch the circulator DANGER OF SCALDING Once all the electrical and hydrauli...

Страница 14: ...duction of the circu lator performance is ensured depending on the lowering of the temperature of the circulating liq uid when the demand for heating is lower Plants with constant flow single pipe and...

Страница 15: ...h set point set by external signal 0 10V or PWM 6 Constant differential pressure regulation with set point depending on temperature 7 Regulation with constant curve with rotation speed set from the di...

Страница 16: ...ial pressure regulation THs 50 C Operating mode auto Set point reduction percentage 50 Type of external analogue signal 0 10V Twin operating mode Alternate every 24h Pump start control EXT from remote...

Страница 17: ...the system again If the error persists change the circulator e37 Low mains voltage LP Switch off system power Wait for the warning lights on the control panel to go off then power the system again Ch...

Страница 18: ...ystem power Wait for the motor to cool down Power the system again e57 e58 f 100 Hz f 5 kHz Check that the PWM external signal is operating and connected as specified Energy Efficiency Index EEI The b...

Страница 19: ...tgroup com Tel 31 416 387280 Fax 31 416 387299 DAB PUMPS B V tHofveld 6 C1 1702 Groot Bijgaarden Belgium info belgium dwtgroup com Tel 32 2 4668353 DAB PUMPS IBERICA S L Calle Verano 18 20 22 28850 To...

Отзывы: