14 

 

 

• From the 1st to the 48th attempt: 1 restart every 30 minutes for 20 seconds each 

• From the 49th attempt: 1 restart every 24 hours for 20 seconds each 

 

 

The DRYRUN alarm can be reset manually: if after this reset the pump still does not detect flow and pressure, attempts will last 20 

seconds.  

 

The pump electronics have an anti-burping system that prevents false priming due to possible water bubbles. 

ANTIFLOOD 

The pump keeps the motor off for 3 seconds when starting. If hydraulic flow is detected during this period, the motor will be kept off as a 

mechanical malfunction of the pump shutter may occur.  

To avoid the same problem, which would lead to an indefinite start-up of the pump motor (as the presence of hydraulic flow would always be 

detected), during normal continuous operation, the motor will be switched off every 60 minutes. 

If the hydraulic flow does not go to zero, as expected, the pump goes into ANTIFLOOD alarm and its motor will be kept off.  

If this alarm is present, the pump must be switched off. Mechanical problems with the non-return valve must be solved. If the valve is still 

mechanically released, e.g. due to vibration of the pump body, the ANTIFLOOD alarm will be removed. 

 

5

 

CLEANING STORAGE MAINTENANCE 

The pump does not require any maintenance. Frost can damage the pump. In very cold temperatures, remove the pump from the 

liquid, empty it and store it away from frost. Before any cleaning work is carried out, the pump must be disconnected from the power 

mains. 

 

Once the pump has been removed from the liquid, it is advisable to clean the following parts with a simple jet of water: 

- Filter (open, see figure 1A) 

- Suction filter with float, in case of version X (see figure 3) 

- Non-return valve. In this case, remove the part concerned as shown in figure 11. 

Be sure to reassemble all parts correctly. 

 

6

 

TROUBLESHOOTING 

 

Before starting to look for faults it is necessary to disconnect the power supply to the pump (take the plug out of the socket). If the 

power cable or any electrical part of the pump is damaged, the repair or replacement must be carried out by the manufacturer or 

by their technical assistance service, or by a person with equivalent qualifications, so as to prevent any risk.

 

 

FAULTS 

PROBABLE CAUSES 

REMEDIES 

The pump does not turn on 

or does not stay on. 

1. Pump is not powered 

1. Check power supply 

2.. No water  

3. Restore the water level 

The pump does not deliver 

water 

1. The suction grid or the pipes are blocked 

1. Remove the obstructions 

2. The impeller is worn or blocked 

2. Replace the impeller or remove the 

blockage 

 

3. The head required is higher than the pump’s characteristics 

 

The flow rate is insufficient 

1. The suction grid is partly blocked 

1-2 Remove any obstructions 

2. The impeller or the delivery pipe are partly blocked or encrusted 

Pump stops (possible 

tripping of the thermal safety 

switch) 

1. The liquid to be pumped is too thick and overheats the motor. 

1-2-3-4 Disconnect the plug and remove the 

cause that caused the overheating, wait for 

the pump to cool down and reinsert the plug. 

2. The water temperature is too high 

3. A solid body is blocking the impeller 

4. Power supply not in accordance with data plate values 

 

Содержание DTRON2 35/120

Страница 1: ...Fig Fig Image Abb Afb Fig Obr Kuva Fig Fig ekil Rys bra Fig Fig 1 Fig 2 Fig 3 Fig 5...

Страница 2: ...Fig 6 Fig 7 Fig 8 Fig 9...

Страница 3: ...Fig 10 Fig 11...

Страница 4: ...onnel in possession of the technical qualifications required by the specific legislation in force The term skilled personnel means persons whose training experience and instruction as well as their kn...

Страница 5: ...y or useful without affecting their essential characteristics 1 GENERAL 1 1 Applications Multistage submerged pump with integrated electronics ideal for use in rainwater systems and irrigation network...

Страница 6: ...0 04 in 1 3 Technical Data DTRON2 pumps are equipped with a filter which can be opened see figure 1 A or closed called X see figure 1 B depending on the application The open filter prevents the passa...

Страница 7: ...n force 2 1 Mechanical Installation Install the pump in a location that is not exposed to freezing When the pump remains inactive at a temperature lower than 0 C it is necessary to ensure that there i...

Страница 8: ...a well Install the pump so that the pump suction is at least 1 m 3 28ft above the bottom of the well to prevent the intake of sand and impurities Use rigid metal pipes to hang the pump and secure the...

Страница 9: ...ee ANTI DRYRUN function Various alarms 4 2 Pump On OFF The pump motor is powered by the electronic control board located inside the pump body with an alternating voltage equal to that of the electrica...

Страница 10: ...mains Once the pump has been removed from the liquid it is advisable to clean the following parts with a simple jet of water Filter open see figure 1A Suction filter with float in case of version X se...

Отзывы: