manualshive.com logo in svg
background image

ENGLISH

GB

87

tion of the addresses must be the same for all the devices that make up 

the group: either all automatic or all manual. Setting the same addresses 

is not allowed. 

Both in the case of assigning mixed addresses (some manual and some 

automatic) and in the case of duplicate addresses, an error signal is giv

-

en. The error signal is given by displaying a flashing E in the place of the 

machine address.

If the chosen assignment is automatic, whenever the system is switched 

on addresses are assigned that may be different from the previous time, 

but this does not affect correct operation.

7.5.4  - MS: Measuring system

 

Set the measuring system, choosing between metric and imperial units. 

The quantities displayed are shown in Table 12.

Units of measurement displayed

Quantity

Metric units

Imperial units

Pressure

bar

psi

Temperature

°C

°F

Flow rate

l / min

gal / min

7.5.5  - AS: Association of devices

Allows connection/disconnection with the following devices

• 

e.sy   

Other e.sybox pump for operation in a pump set 

• 

 

 

composed of max 4 elements

• 

e.sylink  e.sylink input output control unit

Table 12: Measuring system

• 

DEV   

Any other compatible devices

The icons of the various connected devices are displayed on page AS with 

below an identifying acronym and the respective reception power.  

An icon lit with a fixed light means that the device is connected and work

-

ing correctly; a stroked through icon means the device is configured as 

part of the network but is not found.

All the devices present over the air are not displayed on this page 

but only the devices that have been associated with our network. 

Seeing only the devices in your own network allows the operation 

of several similar networks existing within the radius of action of 

the wireless without creating ambiguity; in this way the user does 

not see the elements that do not belong to his pumping system.

From this menu page it is possible to associate and disassociate an ele

-

ment from your personal wireless network.

When the machine starts the AS menu item does not show any connection 

because  no  device  is  associated.  In  these  conditions  the  message  “No 

Dev” is shown and the COMM led is off. Only an action by the operator can 

allow devices to be added or removed with the operations of association 

and disassociation.

Association of devices

Pressing ‘+’ for 5 sec puts the machine into the mode where it searches 

for wireless association, communicating this status by the blinking of the 

COMM leds at regular intervals. As soon as two machines in a working 

communication range are put into this status, if possible, they are asso

-

ciated with each other.  If the association is not possible for one or both 

machines, the procedure ends and a pop-up appears on each machine 

saying “association not possible”. An association may not be possible be

-

cause the device you are trying to associate is already present in the max

-

imum number or because the device to be associated is not recognised. In 

the last case repeat the procedure from the start. 
The  search  status  for  association  remains  active  until  the  device  to  be 

associated is detected (irrespective of the result of association); if not de

-

vice can be seen within the space of 1 minutes, the machine automatically 

leaves  association  status. You  can  leave  the  search  status  for  wireless 

NOTE: 

The flow in English-speaking units (gal/min) is indicated adopt

-

ing a conversion factor of 1 gal = 4.0 litres, corresponding to the metric 

gallon.

Содержание DAB E.SYBOX

Страница 1: ...trol unit function setup 75 5 1 5 Association and disassociation of e sybox and control unit 75 6 The keypad and the display 76 6 1 Direct access with a combination of keys 77 6 2 Access by name with...

Страница 2: ...6 19 FW Firmware update 95 7 6 20 RF Fault and warning reset 95 7 6 21 PW Change password 95 7 6 21 1 Password for multipump systems 96 8 Reset and factory settings 96 8 1 Reset generale del sistema 9...

Страница 3: ......

Страница 4: ...rve the warnings may create situations of risk for persons or property and will void the product guarantee KEY The following symbols have been used in the discussion Situation of general danger Failur...

Страница 5: ...Compartment The door can be removed by inserting 2 fingers in the rubber grips squeezing and rotat ing the door around the hinges on the side opposite the grips see Fig 2 To put the door back in place...

Страница 6: ...ressure value in delivery and energy saving The inverter is able to keep the pressure of a hydraulic circuit con stant by varying the rotation speed of the electropump In oper ation without an inverte...

Страница 7: ...pansion vessel until a pressure of 1 0 bar is reached on the valve Failure to respect the above equation may lead to malfunctions of the system or to premature breakage of the diaphragm inside the exp...

Страница 8: ...box 30 50 ELECTRIC POWER SUPPLY Voltage 1 x 220 240 VAC Frequency 50 60 Hz Maximum current 10 A 6 8 A Maximum power 1550 W 900 W CONSTRUCTION CHARACTERISTICS Overall dimensions 565x265x352 mm without...

Страница 9: ...in the water to be pumped install a filter on the system intake that is suitable for catching impurities The installation of a filter on intake causes a decrease of the system s hydraulic performance...

Страница 10: ...type it is recommended to fit a non return valve in the suction section of the system this is to allow the operation of loading the system par 2 1 2 If the installation is of the over head type instal...

Страница 11: ...its height until it contacts the surface so as to ensure the stability of the 10 mm 200 mm 270 mm OUT 1 OUT 2 IN 565 mm 370 mm 265 mm Figure 9 system The system must in fact be placed in a safe and st...

Страница 12: ...p is placed at a level lower than the water to be pumped e g overhead cistern and pump below Installation above head with the aid of the accessory tool Fig 3_point 5 or with a screwdriver remove the f...

Страница 13: ...to it and on the quality of the line The differential switch protecting the system must be correctly sized and must be of the Class A type The automatic differen tial switch must be marked with the f...

Страница 14: ...t leaves the priming procedure and starts its regular work The utility opened in delivery from which the pumped water is coming out can be closed If after 5 minutes of the procedure the product is sti...

Страница 15: ...oes not intervene by restoring the flow of water and resetting the pump the automatic restart will try to restart the pump If the parameter SP is not correctly set the protection against water lack ma...

Страница 16: ...e device is provided with protection against the direct short circuit which may occur between the motor phases When this blockage is indicated you can attempt to restore operation by simultaneously ho...

Страница 17: ...y means of wire less communication to a remote unit referred to below as a control unit Depending on the model the control unit offers a variety of functions The possible control units are e sylink Ta...

Страница 18: ...action System in stop status F3 fault and warning reset No action System in stop status 1 in 9 Fault and warn ing reset No action Fault and warning reset No action No action in 2 10 11 12 13 Kiwa func...

Страница 19: ...ocedure for associating a control unit to an e sybox is the same as for associating an e sybox locate the AS page of the installer menu and hold down the key for 5 sec until the blue LED blinks whethe...

Страница 20: ...5 5 Alarm Red led Lit with a fixed light when the machine is blocked by an error Communication Blue led Lit with a fixed light when communication wireless is used and is working correctly It blinks w...

Страница 21: ...ESS KEYS HOLD DOWN TIME User On releasing the button Monitor 2 Sec Setpoint 2 Sec Manual 5 Sec Installer 5 Sec Technical assistance 5 Sec Reset factory values 2 sec after switching on appliance Reset...

Страница 22: ...E Dissipator temperature RP Decrease pressure for restart TB Block time for water lack Menu Selection BK Back lighting P1 Auxiliary setpoint 1 OD Type of plant T1 Low pr delay TK Backlighting switch o...

Страница 23: ...AY Anti Cycling AE Anti blocking AF AntiFreeze I1 Function input 1 I2 Function input 2 I3 Function input 3 I4 Function input 4 O1 Function output 1 O2 Function output 2 FW Firmware update RF Reset fau...

Страница 24: ...menu you want and enter it by pressing MODE Table 8 Menu structure The items available are MAIN USER MONITOR followed by a fourth item EXTENDED MENU this item allows the number of menus dis played to...

Страница 25: ...puts Specific icons The error conditions are indicated in Table 2 page 76 The other displays are indicated in Table 9 Error or status conditions shown on the main page Identifying code Description GO...

Страница 26: ...sword is set the parameters of the device will be accessible and visible but it will not be possible to change them The password management system is in the technical assistance menu and is managed by...

Страница 27: ...iance is equipped 7 1 12 FF Fault log display Chronological display of the faults that have occurred during system op eration Under the symbol FF appear two numbers x y indicating respectively the Tab...

Страница 28: ...cale from 0 to 100 7 2 3 TK Backlight switch on time Sets the time that the backlight is lit since the last time a key was pressed Values allowed 0 always off from 20 sec to 10 min or always on When t...

Страница 29: ...ws you to scroll through the menu pages the and keys allow you respectively to increase and decrease the value of the parameter concerned Press SET to leave this menu and return to the main menu Enter...

Страница 30: ...tting the pressure fall to restart Expresses the fall in pressure with respect to the SP value which causes restarting of the pump For example if the setpoint pressure is 3 0 bar and RP 0 5 bar the pu...

Страница 31: ...es in your own network allows the operation of several similar networks existing within the radius of action of the wireless without creating ambiguity in this way the user does not see the elements t...

Страница 32: ...paragraph 9 4 5 for further information The remote pressure sensor operates in synergy with the internal sensor so that the pressure never falls below the setpoint pressure in either of the two point...

Страница 33: ...s has the value of the number of devices present automatically detected If a number different from N is set this fixes the maximum num ber of devices that can participate in pumping at the number set...

Страница 34: ...f one device in particular the one configured as reserve but this may be useful in case of necessity when a greater hydraulic load occurs Example 3 A pump set composed of 4 devices N 4 detected automa...

Страница 35: ...unit manual The inputs IN1 IN4 are all the same and all the functions can be associ ated with each of them Parameters I1 I2 I3 and I4 are used to associate the function required to the corresponding...

Страница 36: ...l remove the alarm when none is activated Table 14 Configurations of the digital inputs Behaviour of the external float function depending on INx and on the input Value of Parameter Ix Input configu r...

Страница 37: ...unctions are configured at the same time on different inputs the system will indicate F3 when at least one function is activated and will remove the alarm when none is activated For the system to work...

Страница 38: ...e same time on different inputs the system will indicate F4 when at least one function is activated and will remove the alarm when none is activated Response of low pressure detection function KIWA ac...

Страница 39: ...er of faults present in the log is indicated under the symbol RF max 64 The log can be viewed from the MONITOR menu on page FF 7 6 21 PW Change password The device has a password enabled protection sy...

Страница 40: ...e settings saved by the user 8 2 Factory settings The device leaves the factory with a series of preset parameters which may be changed according to the user s requirements Each change of the settings...

Страница 41: ...m 0 International TB Blockage time for water lack s 10 T1 Low pr delay KIWA s 2 T2 Delay in switching off s 10 GP Proportional gain coefficient 0 5 GI Integral gain coefficient 1 2 RM Maximum speed rp...

Страница 42: ...and mandatory where local regulations require it to force the closure of the recirculating pipe losing the self priming capacity This obtains the advantage of eliminating the clicking noise of the pi...

Страница 43: ...ice to replace the system with a spare in the event of special maintenance The system mounted on its quick connection interface appears as in Fig 20 9 4 Multiple Sets 9 4 1 Introduction to multipump s...

Страница 44: ...es Parameters linked to multipump operation The parameters shown on the menu for multipump operation are classified as follows Read only parameters Parameters with local significance Multipump system...

Страница 45: ...s are compatible the device with factory con figuration automatically assumes the sensitive parameters of the chain Parameters with optional alignment These are parameters for which it is tolerated th...

Страница 46: ...ority requires that the device that has been stopped for 23 hours be given maximum priority in the starting order This means that as soon as it is necessary to supply flow it will be the first to star...

Страница 47: ...sconnect the power supply before starting any work on the sys tem The system requires no routine maintenance operations However below are the instructions for performing the special mainte nance opera...

Страница 48: ...t does not get lost or else put it back in its seat inside key 3 at the end of operations Use of end C this is practically a straight tip screwdriver of the correct size for manoeu vring the caps of t...

Страница 49: ...gh essentially drained the system is unable to expel all the Figura 26 water that it contains During handling of the system after emptying it some small amounts of water may probably leak out from the...

Страница 50: ...etween the moving part motor shaft and the fixed part of the pump thus increasing the resistance on starting In this case it may be sufficient to help the motor shaft by hand to detach itself from the...

Страница 51: ...ut in 3 ways Manual always possible in the case of e sybox 30 50 while for e sybox the Master must have a firmware version of 4 00 or higher It is not nec essary to associate the e sybox Automatic alw...

Страница 52: ...time The e sybox used as the Master must have a firmware version of 4 00 or more The e sybox used as the Slave must have a firmware version of less than 4 00 Association between different firmware ver...

Страница 53: ...tance service 3 Check the suction pipe find and eliminate the cause of air getting in 4 Contact the assistance centre Insufficient delivery Red off White on Blue off 1 Suction depth too high 2 Suction...

Страница 54: ...cables The display shows Press to propagate this config Red off White on Blue off One or more devices have sensitive param eters not aligned Press the key on the device which we are sure has the most...

Отзывы: