DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
15
Programmable output 4
No.
Name
Range
Factory Setting
o400
Function of output 4
0 - 4
0
0
Disabled
1
Position indication/Movement/Warning. Signal as configured in o410 – o422
2
Presence detection/Direction sensing. Signal as configured in o491
3
Lock
4
Alarm output Signal as configured in o430 – o442
o410
Open position
0 - 2
0
0
Disabled
1
Constant signal
2
Flashing signal
o411
Mid position
0 - 2
1
0
Disabled
1
Constant signal
2
Flashing signal
o412
Closed position
0 - 2
1
0
Disabled
1
Constant signal
2
Flashing signal
o413
Movement
0 - 7
0
0
Disabled
1
Constant signal in the opening movement
2
Constant signal in the closing movement
3
Constant signal in the opening and closing movement
4
No signal during movement, used in combination with o410, o411 and o412.
5
Flashing signal in the opening movement
6
Flashing signal in the closing movement
7
Flashing signal in the opening and closing movement
o414
Delayed switch-off Switch off after the specified time For
example to switch off lighting a specified time after closing
0.00-9.59 minutes
0.00
o420
Warning time before start
0.00-9.59 minutes
0.00
o421
Warning function in combination with o420
1 - 8
2
1
Constant signal before automatic closing
2
Constant signal before park and automatic closing
3
Constant signal before close signal, park and automatic closing
4
Constant signal before all signals
5
Flashing signal before automatic closing
6
Flashing signal before park and automatic closing
7
Flashing signal before close signal, park and automatic closing
8
Flashing signal before all signals