DAAB OUTPUT CARD DB406 INSTRUCTION MANUAL
5
Installing the Delta VFD-EL frequency converter
• Modification of the motor winder
The following criteria must be met in order to use the DAAB motor winder with the frequency converter:
• The limit switch cams must be wider than normal.
• FAAC Nordic AB recommends using a motor with a speed of 2,800 rpm.
• Programming the frequency converter
In start mode F XX (XX = frequency) is displayed. Press the ENTER button to enter programming mode (press the button
once for X-). Select the desired group and press ENTER again – (X-XX) is displayed. Select the desired channel and press
ENTER again – (dX) is displayed. Set the desired value, press ENTER again, when the channel is displayed again press
MODE until the display returns to F XX.
• Channel settings in the frequency converter
Channel
no.
Description
Fixed
value
Value to be
adjusted
00-03
used to display the output frequency during operation
1
01-00
used to set the maximum output frequency
70 Hz
01-03
used to set the low frequency
7,5 Hz
01-04
used to set the low frequency voltage
60 V
01-05
used to set the start frequency
1,5 Hz
01-06
used to set the start frequency voltage
40 V
01-09
used to set the acceleration time
01-10
Used to define the retardation time
02-00
used to set the control method
0
02-01
used to set the start method
1
02-02
used to set the type of stop
1
02-04
used to block reversing
1
03-00
used to set the multifunction output
1
03-08
used to set the internal cooling fan
2
04-06
used to set the function of input MI4
2
04-05
used to set the function of input MI3
1
04-04
used to set the function of input MI1
0
*
used to set the opening speed
05-00
used to set braking in the opening movement
05-01
used to set the closing speed
05-02
used to set braking in the closing movement
06-01
used to set the over-current protection
170
06-06
used to set the electronic overload relay
2
08-08
used to set the current limit for a speed increase
170
08-15
used to set the number of start attempts before an error message is generated
0
* = This is set using the arrow keys on the display when the frequency converter is in F XX mode. This setting does not use a
channel.
1,5 sek
1,5 sek
50Hz
15Hz
30Hz
15Hz