background image

5

Picture Surface

1" x 3" Cleat

2" Moulding

Tensioned Professional Electrol® Installation

Ceiling Mount  

Without Hangers

Screen case is placed flush with 
the wall and ceiling and held in 
position by moulding securely 
attached to the wall.

Recessed Above Ceiling

Other methods of installation  
will suggest themselves in new 
buildings where it would be an 
easy matter to provide a recess 
for the screen to conceal it when 
not in use.
Do not seal in—allow access.

Wall or Ceiling Mount With Hangers

Wall type hangers and ceiling type hangers are 
standard equipment. One set is supplied with 
each screen. Useful for recessed installations.

Wall Type Hanger

For Exposed Installation

If the screen is to be mounted in an exposed  
position, it may be covered with finished  
plywood, veneer, paneling, plastic wall covering  
or a valance.

Suggested Methods of Installation

Electrical 

Outlet Box

9 1/2"

11 5⁄16"

Reinforced

Top

Motor End

Picture 
Surface

Picture 
Surface

Ceiling Type Hanger

Picture 
Surface

Rafters

Содержание Tensioned Professional Electrol

Страница 1: ...INSTRUCTION BOOK FOR Tensioned Professional Electrol...

Страница 2: ...iance Contact an authorized service dealer when repair work is required Incorrect reassembly can cause electric shock when the appliance is used subsequently 5 The use of an accessory attachment not r...

Страница 3: ...cement 2 Make sure hangers are placed to fit into notches of ironing board Installation 11 1 2 11 1 2 Screens Over 22 Wide Figure 3 11 1 2 11 1 2 Screens 22 Wide And Under Case Length 2 Case Length 2...

Страница 4: ...cut wrapping paper with knive or any sharp tool Remove by hand ATTENTION Ne coupez pas le papier d emballage ou le ruban adh sif avec un couteau ou un outil tranchant Retirez la main 5 Install electr...

Страница 5: ...een to conceal it when not in use Do not seal in allow access Wall or Ceiling Mount With Hangers Wall type hangers and ceiling type hangers are standard equipment One set is supplied with each screen...

Страница 6: ...s le moteur de l cran a besoin d tre ajust Black With Yellow To junction box mounted in screen case in which interal wiring terminates in white black and red leads In multiple control installations th...

Страница 7: ...across red and white leads Power at junction box Thermal overload tripped Let motor cool down for 15 minutes Try again Broken wire in the down or up position Check for continuity Cut off old splice an...

Страница 8: ...AXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANTABILITY Any implied warranties of f...

Отзывы: