9
1.
Remove the cover plate from the 3-button wall switch and
remove the switch from the junction box.
2. Locate small 3-position switch on back of wall switch. See
Figure 5 for 120V screens or Figure 8 for 220/240V screens.
3. To adjust the down limit switch, slide the 3-position switch to
the down position. Press and hold the down button to run
the screen down to the desired stop position. Release the
button to stop the screen. DO NOT PUSH THE STOP
BUTTON.
CAUTION: Do not adjust for more drop than what was
ordered. At least 1–1/2 wraps of fabric must remain on
the roller. This screen comes standard with 12" black at
the top. See the specification data sheet for details.
ATTENTION! N'effectuez pas de réglage pour obtenir un
déroulement supérieur à celui commandé. Au moins 1 à
1/2 tour de toile doit être maintenu sur le cylindre. Ce
écran est doté de série d'une bande noire supérieure de
30,5 cm (12 po).
4. When the screen is in the desired down position, slide the
3-position switch to the off (center) position. The down limit
switch is now set.
5. To adjust the up limit switch, slide the 3-position switch to
the up position. Press and hold the up button to run the
screen up to the desired stop position. Release the button to
stop the screen. DO NOT PUSH THE STOP BUTTON.
CAUTION: Adjusting the down limit switch for less drop
by more than 6” can cause the screen surface to lose
proper tensioning.
ATTENTION! Le fait d'ajouter ne déroulez pas trop l'écran
plus de 15 cm (6po) aux interrupteurs de fin de course
peut faire perdre la bonne tension à la surface de l'écran.
6. When the screen is in the desired up position, slide the
3-position switch to the off (center) position. The up limit
switch is now set.
7.
To test limit switch setting, make sure the 3-position switch is
in the off (center) position. Press and release the up or down
button on the wall switch to operate the screen.
8. Replace switch and cover plate on the wall.
NOTE:
If stop button is pressed, the wall switch will reverse
direction. To correct this, press the stop button again. This
will reset the switch. You will have to re-set both the up and
the down limit settings.
IMPORTANT
NOTE:
The wall switch is REQUIRED to make
any limit switch adjustments, EVEN if a third party control
system is used. Therefore, it is advised to wire the switch or
provide a 4-conductor connection that is accessible.
Screen Adjustment for 220V/240V Screens
Low Voltage Connections for 220V/240V Screens with Built-In Low Voltage Control
Control Panel
A control panel may be connected to the integrated LVC by
using the wall switch wire lead. The control panel must provide a
momentary, dry contact closure of at least 1/2 second.
1. Use 3-conductor 20-24 gauge wire to connect the control panel
to the wall switch lead.
2. A momentary closure across the white and red wires will be an
“up” command.
3. A momentary closure across the white and black wires will be a
“down” command.
4. A momentary closure across the white, red and black wires will
be a “stop” command.