TROUBLESHOOTING
SYMPTOM
1. Screen or mask will not operate.
Motor does
not
hum.
Motor
hums.
CAUSE
(a) Blown facility fuse.
(b) Tripped facility circuit breaker.
(c)
No power
to receptacle in junction
box.
(d) No power to bus interface unit.
(e) Loose control wire connections
Power at junction box
(f) Thermal overload tripped.
(g) Transformer not plugged in.
(h) Defective motor.
(i)
Temporary binding.
SOLUTION
(a) Replace facility fuse.
(b) Reset facility circuit breaker.
(c) Check above. Tighten all loose
wire connections. Recheck
wiring. See installation
instructions.
(d) Make sure transformer is
connected to bus interface – see
wiring diagram.
Defective transformer – replace.
(e) Check all T4 and T6 wire
connections – see wiring
diagram.
(f) Let motor cool down for 15
minutes. Try again.
(g) Plug transformer into receptacle
on non-motor end of screen.
(h) Replace motor assembly.
NOTE: Motor is a sealed assembly.
(i)
With power
“off,”
turn roller by
hand to free binding.
2. Image on screen does not match
picture area.
(a) Screen not set to the correct
format.
(b) Screen or mask out of
adjustment.
(a) Set screen to the format being
projected.
(b) See screen adjustment. We
recommend you have your dealer
make these adjustments for you.
6
3. Noise.
NOTE: Screen will operate with a
low-pitched hum.
(a) Grinding. Foreign object in screen
rubbing on roller or fabric.
(a) Remove.
4. Coasting.
(a) Defective brake.
(a) Replace motor assembly.
5. Fabric hangs crooked.
(a) Screen not installed properly.
(b) Fabric has backed up inside case.
(c) Fabric is damaged.
(a) Check for level and plumb.
(b) Lower screen and carefully pull
fabric to remove any slack on the
roller.
(c) Replace fabric.
Содержание TENSIONED HORIZON ELECTROL