background image

ELECTRICAL INSTALLATION

3

LOW-VOLTAGE 
WALL SWITCH

INFRARED 
SENSOR INPUT

MOTOR

WHITE (COMMON)

BLACK (HOT)

GREEN

GROUND TO CASE

RED

BLACK

WHITE (COMMON)

EYE AUX

120VAC 60HZ

120V WIRING DIAGRAM 

WITH BUILT-IN LOW 

VOLTAGE CONTROL

WHITE

RED

BLACK

UP

STOP

DOWN

GROUND–MUST 

BE CONNECTED 

TO BUILDING 

GROUND

240V WIRING DIAGRAM 

WITH BUILT-IN LOW 

VOLTAGE CONTROL

MOTOR

BLUE (COMMON)

BROWN (HOT)

GREEN

BLACK

BLACK (UP)

BROWN (DOWN)

BLUE (COMMON)

GROUND TO CASE

AUX EYE

240VAC 50HZ

INFRARED SENSOR 
INPUT

WHITE

RED

BLACK

LOW-VOLTAGE 
WALL SWITCH

UP

STOP

DOWN

GROUND–MUST 

BE CONNECTED 

TO BUILDING 

GROUND

BLACK

NOTE: Wired 10' Power Cord Included

NOTE: Wired 10' Power Cord Included

Содержание DESIGNER CONTOUR ELECTROL Series

Страница 1: ...t Office Box 137 Warsaw Indiana 46581 0137 Phone 574 267 8101 800 622 3737 Fax 574 267 7804 Toll Free Fax 877 325 4832 www da lite com e mail info da lite com Instruction Book for Designer Contour Electrol with built in infrared remote The Da Lite Difference ...

Страница 2: ... with a current rating at least equal to that of the appliance should be used Cords rated for less amperage than the appliance may overheat 4 To reduce the risk of electric shock do not disassemble this appliance Contact an authorized service dealer when repair work is required Incorrect reassembly can cause electric shock when the appliance is used subsequently 5 The use of an accessory attachmen...

Страница 3: ...he screen brackets 3 The top of the screen case has a channel that the ceiling mount brackets slide into Remove the end cap on the right end of the case and insert the brackets into the case channel Lock the brackets in place by tightening two set screws Refer to figure 2 Mount can not be more than 12 from end of case 4 Hold the screen case up to the ceiling and mark the hole locations Drill holes...

Страница 4: ...TE RED BLACK UP STOP DOWN GROUND MUST BE CONNECTED TO BUILDING GROUND 240V WIRING DIAGRAM WITH BUILT IN LOW VOLTAGE CONTROL MOTOR BLUE COMMON BROWN HOT GREEN BLACK BLACK UP BROWN DOWN BLUE COMMON GROUND TO CASE AUX EYE 240VAC 50HZ infrared sensor input WHITE RED BLACK LOW VOLTAGE WALL SWITCH UP STOP DOWN GROUND MUST BE CONNECTED TO BUILDING GROUND BLACK NOTE Wired 10 Power Cord Included NOTE Wired...

Страница 5: ...se the amount of screen drop Run the screen down to test the stop position If the screen drops too far raise the screen about one foot and adjust the limit switch again Repeat until the desired position is set TO INCREASE SCREEN DROP Turn the red limit switch screw counterclockwise to increase the amount of screen drop Run the screen down to test the stop position If the screen does not drop enoug...

Страница 6: ...e connections Correct any improper connections Down Position Check for power across black and white leads Up Position Check for power across red and white leads e Let motor cool down for 15 minutes Try again f Check for continuity Cut off old splice and reconnect g Replace motor assembly NOTE Motor is a sealed assembly h Replace motor assembly a See instructions below b See installation instructio...

Страница 7: ...6 THIS PAGE IS INTENTIONALLY LEFT BLANK ...

Страница 8: ...e by the purchaser and Da Lite is not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANT ABILITY Any implied warranties of fitness for use or merchantability that may be mandated b...

Отзывы: