D-tect Systems D-TECT GJD360/AM Скачать руководство пользователя страница 6

Detection Area

Programmable between 10 & 30m 

Coverage

10-70 degrees detection angle, 30m x 30m coverage max.

Adjustment

180 degree pan + 90 degree tilt

Fresnel Lens

28 zones for each Pyro pair, which can be masked with the curtain sliders

Customised Optics

Double silicon shielded quad element eliminates 50,000 Lux of White-Light

Microwave Module

Operating Frequency. Country dependent                              GHz  10 dBm EIRP

Outputs

Silent solid state magnetically immune

No. 1

N/OPEN

Volt free relay signal contact 24VAC/DC @ 50mA 

with an integral 25R series resistor

Alarm time 5 seconds

No.2 

N/CLOSED

Volt free relay signal contact 24VAC/DC @ 50mA  

with an integral 25R series resistor

Alarm time 5 seconds

Power Input

9 to 15 VDC

Current

15mA (12V nominal)

Pulse Count

1 -  2

Temp Compensation

Digital sensitivity adjustment

Control

Digital microprocessor - non volatile memory

Walk Test

Output test mode with LED indication

Operating Temp

-20ºC to +55º C

Conformally coated electronics for increased stability

Housing

High impact zinc alloy 

Protection Rating

IP55

Dimensions

145 x 120 x 115 mm

Weight

750grams NET, 880 grams GROSS

Mounting Height

Variable - optimum height 3 metres

Cable <200m 

Utilising all three outputs (incl. tamper) - 8 core 7/0.2mm

Cable <500m 

Utilising all three outputs (incl. tamper) - 8 core 16/0.2mm

CE Mark

SIMPLIFIED EU DECLARATION OF CONFORMITY

Hereby, GJD Manufacturing Ltd declares that the radio equipment type GJD360AM Dualtech Anti-Mask Detector 

is in compliance with Directive 2014/53/EU.

The full text of the EU declaration of conformity is available at the following internet address: gjd.co.uk

All manuals and user guides at all-guides.com

all-guides.com

Содержание D-TECT GJD360/AM

Страница 1: ...pplying power to the detector During the first 10 seconds after power has been connected the amber LED flashes and the anti masking circuit starts to self calibrate The amber LED indicates when the de...

Страница 2: ...re an alarm is generated STAGE 2 Connecting the Unit STAGE 3 Multibeam Alignment Masking The GJD multifunction lens fitted to the D TECT detector produces 7 long range beams and 7 medium to short rang...

Страница 3: ...w flash once 4 Press the program button twice and release the button 5 The indicator flashes twice showing that the option has been stored and the detector returns to normal operation 1 2 3 1 Range m...

Страница 4: ...Figure 1 Optional for Tamper Cup Cable Holes Template Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 All manuals and user guides at all guides com...

Страница 5: ...Figure 7 Figure 8 A M ALARM NC TAMPER ALARM NO 9 15 VDC Figure 9 Figure 10 A M ALARM NC TAMPER ALARM NO 9 15 VDC PROGRAM Program Button Blue LED All manuals and user guides at all guides com...

Страница 6: ...Pulse Count 1 2 Temp Compensation Digital sensitivity adjustment Control Digital microprocessor non volatile memory Walk Test Output test mode with LED indication Operating Temp 20 C to 55 C Conforma...

Страница 7: ...Unit 2 Birch Business Park Whittle Lane Heywood Greater Manchester OL10 2SX UK www gjd co uk info gjd co uk 44 0 1706 363 998 ENGINEER NOTES All manuals and user guides at all guides com...