SET TEMPERATURE:
MUST BE ADJUSTED BEFORE FIRST USE
1
Press
SET
button once to adjust temperature.
Screen will display
‘
CLSE’
Pressing
SET
twice will display
‘A 2 S E ’
which is the alarm set point and doesn’t
need adjustment.
Default value is 1112.
Pressing
SET
again will return to temperature.
2
Press
UP
and
DOWN
arrows to select temperature.
Screen will display selected temperature.
3
When display stops flashing, temperature is set.
AFTER USE:
TAKE CARE: UNLESS GIVEN TIME TO COOL, HEATER & NAIL WILL BE HOT
1
Flip
HEATER SWITCH (C)
to off position.
Heater & Nail will be hot, allow time to cool.
2
To unplug heater: press metal tab above
HEATER INPUT (A)
while gently pulling
heater end. Do not tug on cord.
CLEAN CONTROLLER:
POWER OFF CONTROLLER BEFORE CLEANING
Wipe
CONTROLLER FACE (B)
with a soft, dry
cloth. Other surfaces can be cleaned with a
soft damp cloth
(wet with water or isopropyl alcohol)
.
CONTROL FACE
BUTTONS