background image

D-Link GO-SW-5G/8G 5/8-port Gigabit Easy Desktop Switch

 

12 

Glossary 

1000BASE-SX 

 

A short laser wavelength on multimode fiber optic cable for a maximum length of 550 meters.

 

1000BASE-LX 

 

A long wavelength for a "long haul" fiber optic cable for a maximum length of 10 kilometers.

 

100BASE-FX 

– 100Mbps Ethernet implementation over fiber. 

100BASE-TX 

– 100Mbps Ethernet implementation over Category 5 and Type 1 Twisted Pair cabling. 

10BASE-T 

– The IEEE 802.3 specification for Ethernet over Unshielded Twisted Pair (UTP) cabling. 

aging 

–  The automatic removal of dynamic entries from the Switch Database which have timed-out and are no longer 

valid. 

ATM 

 

Asynchronous Transfer Mode. A connection oriented transmission protocol based on fixed length cells 

(packets). ATM is designed to carry a complete range of user traffic, including voice, data, and video signals. 

auto-negotiation 

– A feature on a port, which allows it to advertise its capabilities for speed, duplex, and flow control. 

When connected to an end station that also supports auto-negotiation, the link can self-detect its optimum operating 
setup.  

backbone port 

 

A port that does not learn device addresses, and that receives all frames with an unknown address. 

Backbone ports are normally used to connect the Switch to the backbone of your network. Note that backbone ports 
were formerly known as designated downlink ports. 

backbone 

 

The part of a network used as the primary path for transporting traffic between network segments. 

Bandwidth 

– Information capacity, measured in bits per second, that a channel can transmit. The bandwidth of 

Ethernet is 10Mbps, the bandwidth of Fast Ethernet is 100Mbps. 

baud rate 

– The switching speed of a line. Also known as 

line speed

BOOTP 

– The BOOTP protocol allows you to automatically map an IP address to a given MAC address each time a 

device is started. In addition, the protocol can assign the subnet mask and default gateway to a device. 

bridge 

– A device that interconnects local or remote networks no matter what higher level protocols are involved. 

Bridges form a single logical network, centralizing network administration. 

broadcast 

– A message sent to all destination devices on the network. 

broadcast storm 

– Multiple simultaneous broadcasts that typically absorb available network bandwidth and can cause 

network failure. 

console port 

– The port on the Switch accepting a terminal or modem connector. It changes the parallel arrangement 

of data within computers to the serial form used on data transmission links. This port is most often used for dedicated 
local management. 

CSMA/CD 

– Channel access method used by Ethernet and IEEE 802.3 standards, in which devices transmit only after 

finding the data channel clear for some period of time. When two devices transmit simultaneously, a collision occurs 
and the colliding devices delay their retransmissions for a random amount of time. 

data center switching 

– The point of aggregation within a corporate network where a switch provides high-

performance access to server farms, a high-speed backbone connection, and a control point for network management 
and security. 

Ethernet

 – A LAN specification developed jointly by Xerox, Intel, and Digital Equipment Corporation. Ethernet 

networks operate at 10Mbps using CSMA/CD to run over cabling. 

Fast Ethernet 

– 100Mbps technology based on the Ethernet/CD network access method. 

Flow Control 

– (IEEE 802.3x) A means of holding packets back at the transmit port of the connected end station. 

Prevents packet loss at a congested switch port. 

forwarding 

– The process of sending a packet toward its destination by an internetworking device. 

full duplex 

– A system that allows packets to be transmitted and received at the same time and, in effect, doubles the 

potential throughput of a link. 

half duplex 

– A system that allows packets to be transmitted and received, but not at the same time. Contrast with 

full 

duplex

IP address 

– Internet Protocol address. A unique identifier for a device attached to a network using TCP/IP. The 

address is written as four octets separated with full-stops (periods), and is made up of a network section, an optional 
subnet section and a host section. 

IPX 

– Internetwork Packet Exchange. A protocol allowing communication in a NetWare network. 

LAN 

– Local Area Network. A network of connected computing resources (such as PCs, printers, servers) covering a 

relatively small geographic area (usually not larger than a floor or building). Characterized by high data rates and low 
error rates. 

Содержание GO-SW-5G

Страница 1: ...GO SW 5G 8G 5 8 port Gigabit Easy Desktop Switch Manual RECYCLABLE V2 10 ...

Страница 2: ...This is a Class B product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Warnung Dies ist ein Produkt der Klasse B Im Wohnbereich kann dieses Produkt Funkstoerungen verursachen In diesem Fall kann vom Benutzer verlangt werden angemessene Massnahmen zu ergreifen Precaución Este es un producto de Clase B En un ento...

Страница 3: ...HNOLOGY 1 SWITCHING TECHNOLOGY 2 SWITCH DESCRIPTION 2 Features 2 FRONT PANEL COMPONENTS 3 LED Indicators 4 REAR PANEL DESCRIPTION 5 INSTALLATION 6 Package Contents 6 BEFORE YOU CONNECT TO THE NETWORK 6 POWER ON 7 Power Failure 7 CONNECTING THE SWITCH 8 SWITCH TO END NODE 8 SWITCH TO HUB OR SWITCH 8 CONNECTING TO NETWORK BACKBONE OR SERVER 9 TECHNICAL SPECIFICATIONS 10 GLOSSARY 12 ...

Страница 4: ...Switch to an end node hub Switch or backbone server Appendix A Technical Specifications The technical specifications of the GO SW 5G GO SW 8G Glossary Lists definitions for terms and acronyms used in this document Intended Readers The GO SW 5G GO SW 8G Manual contains information for setup and management and of the GO SW 5G GO SW 8G Switch This manual is intended for network managers familiar with...

Страница 5: ...f power source required consult your service provider or local power company To help avoid damaging your system be sure the voltage selection switch if provided on the power supply is set to match the power available at your location 115 volts V 60 hertz Hz in most of North and South America and some Far Eastern countries such as South Korea and Taiwan 100 V 50 Hz in eastern Japan and 100 V 60 Hz ...

Страница 6: ...are secured to the rack extended to the floor and that the full weight of the rack rests on the floor Install front and side stabilizers on a single rack or front stabilizers for joined multiple racks before working on the rack Always load the rack from the bottom up and load the heaviest item in the rack first Make sure that the rack is level and stable before extending a component from the rack ...

Страница 7: ...ake the following steps to prevent damage from electrostatic discharge ESD 1 When unpacking a static sensitive component from its shipping carton do not remove the component from the antistatic packing material until you are ready to install the component in your system Just before unwrapping the antistatic packaging be sure to discharge static electricity from your body 2 When transporting a sens...

Страница 8: ...ttlenecks that frequently develop as computers and their busses get faster and more users use applications that generate more traffic Upgrading key components such as your backbone and servers to Gigabit Ethernet can greatly improve network response times as well as significantly speed up the traffic between your subnetworks Gigabit Ethernet enables fast optical fiber connections to support video ...

Страница 9: ...can be used to split parts of the network into different collision domains for example making it possible to expand your Fast Ethernet network beyond the 205 meter network diameter limit for 100BASE TX networks Switches supporting both traditional 10Mbps Ethernet and 100Mbps Fast Ethernet are also ideal for bridging between existing 10Mbps networks and new 100Mbps networks Switching LAN technology...

Страница 10: ...r data buffering IEEE 802 3x flow control for full duplex Back pressure flow control for half duplex Jumbo Frame Support at 1000Mbps 9216Bytes Front Panel Components The top case of the Switch consists of LED indicators 5 8 10 100 1000 Mbps Ethernet ports Figure 1 1 Front Panel View of the Switch Comprehensive LED indicators display the status of the Switch and the network ...

Страница 11: ...Indicators The LED indicators of the Switch include Power and Link Act as described below For GO SW 5G Power Indicator This green indicator light is on when the Switch is receiving power otherwise it is off Link Act This LED indicator light is green when the port is connected to a device The green indicator blinks as data is transmitted or received For GO SW 8G Power Indicator This green indicator...

Страница 12: ... power adapter Check the technical specification section for information about the AC power input voltage Figure 1 3 Rear panel view of the Switch 10 100 1000BASE T Ports Five and eight 5 8 Gigabit Ethernet Auto Negotiating ports 10 100 1000Mbps Comprehensive LED indicators display the conditions of the Switch and status of the network ...

Страница 13: ...l surface that can support at least 3 kg 6 6 lbs of weight Do not place heavy objects on the Switch The power outlet should be within 1 82 meters 6 feet of the Switch Visually inspect the power cord and see that it is fully secured to the AC power port Make sure that there is adequate space for proper heat dissipation from and adequate ventilation around the Switch Leave at least 10 cm 4 inches of...

Страница 14: ... of the Switch and the other end into the local power source outlet After the Switch is powered on the LED indicators will momentarily blink This blinking of the LED indicators represents a reset of the system Power Failure As a precaution in the event of a power failure unplug the Switch When power is resumed plug the Switch back in ...

Страница 15: ...e connected to any of the ports of the Switch Figure 3 1 Switch connected to an end node Switch to Hub or Switch These connections can be accomplished in a number of ways using a standard Ethernet cable A 10BASE T hub or switch can be connected to the Switch via a twisted pair Category 3 4 5 or 5e UTP STP cable A 100BASE T hub or switch can be connected to the Switch via a twisted pair Category 5 ...

Страница 16: ... to a port on a hub or switch using either a straight or crossover cable any standard Ethernet cable is fine Connecting To Network Backbone or Server Any of the five Gigabit Ethernet ports are ideal for uplinking to a network backbone or network server Figure 3 3 Connection to a Server ...

Страница 17: ...lex Gigabit Ethernet 2000Mbps Full duplex Topology Star Network Cables Ethernet 2 pair UTP Cat 3 4 5 Unshield Twisted Pair UTP Cable Fast Ethernet 2 pair UTP Cat 5 Unshield Twisted Pair UTP Cable Gigabit Ethernet 4 pair UTP Cat 5 Unshield Twisted Pair UTP Cable Number of Ports Five Eight 10 100 1000BASE T Gigabit Ethernet ports Physical and Environmental DC Inputs AC DC 5V 1A Operating Temperature...

Страница 18: ...tch 11 Performance Transmission Method Store and forward RAM Buffer 128KBytes per device Filtering Address Table 2K GO SW 5G 8K GO SW 8G MAC address per device Packet Filtering Forwarding Rate Full wire speed MAC Address Learning Self learning auto aging ...

Страница 19: ... to all destination devices on the network broadcast storm Multiple simultaneous broadcasts that typically absorb available network bandwidth and can cause network failure console port The port on the Switch accepting a terminal or modem connector It changes the parallel arrangement of data within computers to the serial form used on data transmission links This port is most often used for dedicat...

Страница 20: ...t Protocol A protocol originally designed to be used in managing TCP IP internets SNMP is presently implemented on a wide range of computers and networking equipment and may be used to manage many aspects of network and end station operation Spanning Tree Protocol STP A bridge based system for providing fault tolerance on networks STP works by allowing you to implement parallel paths for network t...

Отзывы: