DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide
40
Start Trap
coldStart
A coldStart trap signifies that the
SNMPv2 entity, acting in an agent role,
is reinitializing itself and that its
configuration may have been altered.
1.3.6.1.6.3.1.1.5.1
warmStart
A warmStart trap signifies that the
SNMPv2 entity, acting in an agent role,
is reinitializing itself such that its
configuration is unaltered.
1.3.6.1.6.3.1.1.5.2
Authentication
authenticationFailure
An authenticationFailure trap signifies
that the SNMPv2 entity, acting in an
agent role, has received a protocol
message that is not properly
authenticated. While all
implementations of the SNMPv2 must
be capable of generating this trap, the
snmpEnableAuthenTraps object
indicates whether this trap will be
generated.
1.3.6.1.6.3.1.1.5.5
RMON
risingAlarm
The SNMP trap that is generated when
an alarm entry crosses its rising
threshold and generates an event that
is configured for sending SNMP traps.
Binding objects:
(1) alarmIndex
(2) alarmVariable
(3) alarmSampleType
(4) alarmValue
(5) alarmRisingThreshold
1.3.6.1.2.1.16.0.1
fallingAlarm
The SNMP trap that is generated when
an alarm entry crosses its falling
threshold and generates an event that
is configured for sending SNMP traps.
Binding objects:
(1) alarmIndex
(2) alarmVariable
(3) alarmSampleType
(4) alarmValue
(5) alarmFallingThreshold
1.3.6.1.2.1.16.0.2
Category
Trap Name
Description
OID