Software User Manual
D-Link Unified Access System
12/10/09
Document
34CSFP6XXUWS-SWUM100-D7
Configuring sFlow
Page 123
Figure 62: sFlow Poller Configuration
Table 52: sFlow Poller Configuration
•
Click
Refresh
to refresh the page with the most current data from the switch.
S
F
LOW
S
AMPLER
C
ONFIGURATION
The sFlow Agent collects a statistical packet-based sampling of the switched flows and sends them to the configured
receivers. A data source configured to collect flow samples is called a sampler.
Packet Flow Sampling
The Packet Flow Sampling mechanism carried out by each sFlow instance ensures that any packet observed at a Data
Source has an equal chance of being sampled, irrespective of the Packet Flow(s) to which it belongs.
Packet Flow Sampling is accomplished as follows:
•
When a packet arrives on an interface, the Network Device makes a filtering decision to determine whether the packet
should be dropped.
•
If the packet is not filtered (dropped), a destination interface is assigned by the switching/routing function.
•
At this point, a decision is made on whether or not to sample the packet. The mechanism involves a counter that is
decremented with each packet. When the counter reaches zero, a sample is taken. When a sample is taken, the
counter that indicates how many packets to skip before taking the next sample is reset. The value of the counter is set
to a random integer where the sequence of random integers used over time is the Sampling Rate.
To access the sFlow Sampler Configuration page, click
LAN > Administration > sFlow > Sampler Configuration
in the
navigation tree.
Field
Description
Slot/Port
The sFlow Sampler Datasource for this flow sampler. This Agent will support Physical ports only.
Receiver Index
The sFlowReceiver for this sFlow Counter Poller. If set to zero, the poller configuration is set to the
default and the poller is deleted. Only active receivers can be set. If a receiver expires, then all pollers
associated with the receiver will also expire. The allowed range is 1 to 8.
Poller Interval
The maximum number of seconds between successive samples of the counters associated with this
data source
Содержание DWS-4026
Страница 4: ...UWS Administrator s Guide ...
Страница 20: ...D Link Unified Access System Software User Manual 12 10 09 Page 20 34CSFP6XXUWS SWUM100 D7 ...
Страница 32: ...D Link Unified Access System Software User Manual 12 10 09 Page 32 Document 34CSFP6XXUWS SWUM100 D7 ...
Страница 278: ...D Link Unified Access System Software User Manual 12 10 09 Page 278 Managing LLDP Document 34CSFP6XXUWS SWUM100 D7 ...
Страница 576: ......