Index – The list number of the Route Table.
Default – For change the default setting. Users have to pick the direction
for the default setting changed.
Prefix – The prefix number for the dialed digits. The call will be followed
this route table if the prefix number was matched.
Destination – To decide the destination for this route table.
E.164 – The E.164 number of the destination.
Mini Digits – The mini digits requirement for this route table.
Max Digits – The max digits requirement for this route table.
Hunt Method – Enable the Hunt Group function and pick up the hunt type.
NONE : Disable the Hunt Group function.
GROUP : The Hunt Group function will working for the same group.
User could configure the group in the Line Configuration table.
ALL : The Hunt Group will working for the same type.
Add Data – Add a new record for the route table.
Delete Data – Delete a record for the route table.
Change Default – Change default route table.
3.11 FXO Password
None – Disable this function
Group – The call will search other ports to be the destination with the
same
group
if the origin destination is busy.
All – The call will search other ports to be the destination with the
same type
if
the origin destination is busy.
About the Group setting, Please get more info from the Line Configuration.
You will get the IVR if you make calls from PSTN side. The IVR will ask you the
password you set, and you could make other calls to IP side if the password
you type is correct. Please press the FXO Password button to configure the
password (see figure 3.13)
39