Physical and Environmental

 

DC inputs 

3.3VDC/3A 

Power 
Consumption 

10 watts. (Max.) 

Temperature 

Operating: 0

°

 ~ 50

°

 C, Storage: -10

°

 ~ 70

°

 C 

Humidity 

Operating: 10% ~ 90%, Storage: 5% ~ 90% 

Dimensions 

184 x 124 x 44 mm (W x H x D) 

EMI: 

FCC Class A, CE Mark Class A, VCCI Class A 

Performance

 

Transmits 
Method: 

Store-and-forward 

RAM Buffer: 

512KBytes per device 

Filtering 
Address Table: 

16K entries per device 

Packet 
Filtering/Forwar
ding Rate: 

10Mbps Ethernet: 14,880/pps 
100Mbps Fast Ethernet: 148,800/pps 

MAC Address 
Learning: 

Automatic update 

 

 

Содержание DSH-16 - Hub

Страница 1: ...DSS 16 16 port 10 100Mbps Switch User s Guide Rev 03 MAR 2001 6012 9830016 Printed In Taiwan RECYCLABLE ...

Страница 2: ...OGY 1 SWITCHING TECHNOLOGY 2 FEATURES 3 UNPACKING AND INSTALLATION 11 UNPACKING 11 INSTALLATION 11 IDENTIFYING EXTERNAL COMPONENTS 11 FRONT PANEL 12 REAR PANEL 12 RIGHT SITE PANEL ERROR BOOKMARK NOT DEFINED LED INDICATORS 13 QOS QUALITY OF SERVICE SETTING ERROR BOOKMARK NOT DEFINED CONNECTING THE SWITCH 14 PC TO SWITCH 14 HUB TO SWITCH 14 ...

Страница 3: ...THOUT UPLINK MDI II PORT 15 A Using straight cable 15 B Using crossover cable 15 SWITCH TO SWITCH OTHER DEVICES 15 A Using straight cable 16 B Using crossover cable 16 PORT SPEED DUPLEX MODE 16 TECHNICAL SPECIFICATIONS 15 RJ 45 PIN SPECIFICATION 17 ...

Страница 4: ...tches Overview of this User s Guide Introduction Describes DSS 16 and its features Unpacking and Installation Helps you get started with the basic installation of DSS 16 Identifying External Components Describes the front panel rear panel and LED indicators of DSS 16 Connecting the Switch Tells how you can connect DSS 16 to your Ethernet network Technical Specifications Lists the technical general...

Страница 5: ...on disruptive smooth evolution from the current 10BASE T technology The non disruptive and smooth evolution nature and the dominating potential market base virtually guarantee cost effective and high performance Fast Ethernet solutions in the years to come 100Mbps Fast Ethernet is a new standard specified by the IEEE 802 3 LAN committee It is an extension of the 10Mbps Ethernet standard with the a...

Страница 6: ...ed while still maintaining the same network cabling and adapter cards For Fast Ethernet networks a switch is an effective way of eliminating problems of uplinking Fast Ethernet hubs beyond the two repeater limit A switch can be used to split parts of the network into different collision domains making it possible to expand your Fast Ethernet network beyond the 205 meter network diameter limit The ...

Страница 7: ...and to any number of switches DSS 16 is a perfect choice for 10Mbps network site that could be upgraded to Fast Ethernet in the future Ethernet workgroups can connect to the Switch now and change adapters and hubs anytime later without changing the Switch or reconfiguring the network DSS 16 combines dynamic memory allocation with store and forward switching method to ensure that the buffer is effe...

Страница 8: ...ex mode operation Back pressure flow control for half duplex mode operation Data Forwarding Rate per port at wire speed for both 10Mbps and 100Mbps speed Data Filtering Rate per port at wire speed for both 10Mbps and 100Mbps speed eliminates all error packets runts etc 16K active MAC address entry table with self learning and table ageing 512KBytes RAM buffer per device Broadcast storm protection ...

Страница 9: ... When installing consider the following pointers Install DSS 16 in a fairly cool and dry place See Technical Specification for the acceptable operating temperature and humidity ranges Install DSS 16 in a site free from strong electromagnetic source vibration dust and direct sunlight Leave at least 10cm of space at the left and right hand side of DSS 16 for ventilation Visually inspect the DC power...

Страница 10: ...Panel Twisted Pair Ports Use any of these ports to connect network devices workstations hubs switches etc to DSS 16 These ports are MDI X ports and you can use ordinary straight through twisted pair cables to connect PCs workstations and Servers to DSS 16 If you need to connect these ports to devices with MDI X ports you need to use crossover cables or connect using the Uplink port described below...

Страница 11: ...r outlet will immediately power it on AC Power Connector For the power cord LED Indicators Power Power Indicator This indicator lights green when the hub is receiving power This LED is off indicating no power 10 100M FDX and 10 100M COL 10 100Mbps Full Duplex and 10 100Mbps Collision Indicator This LED indicator lights green when the respective port is in full duplex FDX mode It remains off for ha...

Страница 12: ...ote Use CAT5 or better cable for 100Mbps connection After the connection is made the port LED on DSS 16 will show the status of the connection If LED indicator does not light after making a proper connection check the PC LAN card DSS 16 and DSS 16 port The following are the possible LED indicator status for PC to Switch connection 1 The LINK ACT LED indicator lights green for 100Mbps connection or...

Страница 13: ...g FDX COL LED indicator is OFF LINK ACT LED indicator lights green Hub without Uplink MDI II port If a hub is not equipped with an uplink MDI II port connection can be made using either straight cable or crossover cable A Using straight cable When using straight cable the connection can be made from Switch s uplink MDI II port to any port of the Hub B Using crossover cable When using crossover cab...

Страница 14: ...her switch switch B or other device 1 The LINK ACT LED indicator lights green indicating 100Mbps connection or it lights amber indicating 10Mbps speed 2 The FDX COL LED indicator lights green if the connection is in full duplex mode The LED remains off when the connection is in half duplex mode Port Speed Duplex Mode After a connection is made between DSS 16 and another Ethernet device the system ...

Страница 15: ...otocol CSMA CD Data Transfer Rate Ethernet 10Mbps half duplex 20Mbps full duplex Fast Ethernet 100Mbps half duplex 200Mbps full duplex Topology Star Network Cables 10BASET 2 pair UTP Cat 3 4 5 EIA TIA 568 100 ohm STP 100BASE TX 2 pair UTP Cat 5 EIA TIA 568 100 ohm STP Number of Ports 16 x 10 100Mbps NWay MDI X ports Uplink Port 1 x 10 100Mbps NWay MDI II port shared with port 1 ...

Страница 16: ...torage 5 90 Dimensions 184 x 124 x 44 mm W x H x D EMI FCC Class A CE Mark Class A VCCI Class A Performance Transmits Method Store and forward RAM Buffer 512KBytes per device Filtering Address Table 16K entries per device Packet Filtering Forwar ding Rate 10Mbps Ethernet 14 880 pps 100Mbps Fast Ethernet 148 800 pps MAC Address Learning Automatic update ...

Страница 17: ...The following diagram and tables show the standard RJ 45 receptacle connector and their pin assignments for the switch to network adapter card connection and the straight crossover cable for the switch to switch hub bridge connection RJ 45 Connector pin assignment Contact Media Direct Interface Signal 1 TX transmit 2 TX transmit 3 Rx receive 4 Not used 5 Not used 6 Rx receive 7 Not used 8 Not used...

Страница 18: ...er cable connections MDI II uplink port to MDI X port connection using Straight Cable for connecting from Switch to switch or from Switch to other network device MDI X port to MDI X port connection using Straight Cable for connecting from Switch to switch or from Switch to other network device ...

Страница 19: ...wing measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Shielded interface cables must be used in order to comply with emission limits You are cautioned that changes or ...

Страница 20: ...lies and fans One 1 Year Power Supplies and Fans One 1 Year Spare parts and spare kits Ninety 90 days D Link s sole obligation shall be to repair or replace the defective Hardware at no charge to the original owner Such repair or replacement will be rendered by D Link at an Authorized D Link Service Office The replacement Hardware need not be new or of an identical make model or part D Link may in...

Страница 21: ...ction or if D Link determines in its sole discretion that it is not practical to replace the non conforming Software the price paid by the original licensee for the non conforming Software will be refunded by D Link provided that the non conforming Software and all copies thereof is first returned to D Link The license granted respecting any Software for which a refund is given automatically termi...

Страница 22: ...dance with the foregoing requirements or that is determined by D Link not to be defective or non conforming What Is Not Covered This limited warranty provided by D Link does not cover Products that have been subjected to abuse accident alteration modification tampering negligence misuse faulty installation lack of reasonable care repair or service in any way that is not contemplated in the documen...

Страница 23: ...F GOODWILL WORK STOPPAGE COMPUTER FAILURE OR MALFUNCTION LOSS OF INFORMATION OR DATA CONTAINED IN STORED ON OR INTEGRATED WITH ANY PRODUCT RETURNED TO D LINK FOR WARRANTY SERVICE RESULTING FROM THE USE OF THE PRODUCT RELATING TO WARRANTY SERVICE OR ARISING OUT OF ANY BREACH OF THIS LIMITED WARRANTY EVEN IF D LINK HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES THE SOLE REMEDY FOR A BREACH OF T...

Страница 24: ...ems Inc All other trademarks belong to their respective proprietors Copyright Statement No part of this publication may be reproduced in any form or by any means or used to make any derivative such as translation transformation or adaptation without permission from D Link Corporation D Link Systems Inc as stipulated by the United States Copyright Act of 1976 ...

Отзывы: