37
RAID level migration
Disk array transport
Disk Array Degraded
Disk arrays are made up of physical drives. Logical drives are created on
the disk array. When one of the physical drives in a disk array fails, a
RAID 1, 5 and 10 volume will (or in the case of a RAID 6, two drives must
fail):
The operational status of the disk array becomes
Degraded
.
The operational status of logical drives becomes
Critical
.
The operational status of physical drive becomes
Dead
or
Offline
.
Disk Array Offline
When a disk array and its logical drives go Offline, the data stored in the
logical drives is no longer accessible.
Logical drives based on fault-tolerant disk arrays, RAID 1, 5, and 10, go
Offline
when two physical drives are removed or fail.
RAID 6 can continue to operate when two physical drives are removed
or fail. It will fail when three physical drives are removed or fail.
Logical drives based on non-fault tolerant disk arrays, RAID 0, go
Offline
when a one physical drive is removed or fails.
3.7.4 Disk
Array
Management
To view disk array information:
1. Click
the
Storage
tab.
2. Click
the
Disk Array
button.
3. Mouse-over the disk array you want to see and click the
View
button.
Disk array information includes:
Disk Array ID – DA0, DA1, DA2, etc.