background image

DIS-200G Series Industrial Gigabit Ethernet Smart Managed Switch 

40 

 

Parameter   

Description   

User Name 

Enter an alphanumeric string of up to 32 characters. This is used to 

identify the SNMP users. 

Group Name 

Enter the SNMP group name to which the user belongs. The syntax 

is general string that does not allow spaces. 

SNMP Version 

Select the SNMP version. Options to choose from are 

v1

v2c

, and 

v3

SNMP V3 Encryption 

When selecting 

v3

 in the 

SNMP Version 

drop-down list, this option is 

available. Options to choose from are 

None

Password

, and 

Key. 

Auth-Protocol 

When selecting 

v3

 in the 

SNMP Version

 drop-down list, and 

selecting either 

Password

 or 

Key

 in the SNMP V3 Encryption drop- 

down list, this option is available. Select the authentication level. 
Options to choose from are 

MD5

, and 

SHA

MD5

 - Select to use the HMAC-MD5-96 authentication level. This 

field will require the user to enter a password or a key. 

SHA

 - Specify that the HMAC-SHA authentication protocol will be 

used. This field will require the user to enter a password or a key. 

Priv-Protocol 

When selecting 

v3

 in the 

SNMP

 

Version

 drop-down list, and 

selecting either 

Password

 or 

Key

 in the SNMP V3 Encryption drop- 

down list, this option is available. Select the private protocol. 
Options to choose from are 

None

, and 

DES56

None

 - Specify that no authorization protocol is in use. 

DES56

 - Specify that DES 56-bit encryption is in use, based on the 

CBC-DES (DES-56) standard. This field will require the user to enter 

a password or a key. 

Click the 

Add

 button to add a new entry based on the information entered.   

Click the 

Delete

 button to remove the specified entry. 

 

SNMP Host Table Settings 

This window is used to configure and display the recipient of the SNMP notification. 
To view the following window, click 

Management > SNMP > SNMP Host Table Settings

, as shown 

below: 

 

 

 

 

 

 

 

 

 

Figure 5-9 SNMP Host Table Settings 

Содержание Dis-200G Series

Страница 1: ...DIS 200G Series Industrial Gigabit Ethernet Smart Managed Switch...

Страница 2: ...d in this text D Link and the D Link logo are trademarks of the D Link Corporation Microsoft and Windows are registered trademarks of the Microsoft Corporation Other trademarks and trade names may be...

Страница 3: ...illance Mode 10 3 SAVE AND TOOLS 11 SAVE CONFIGURATION 11 FIRMWARE INFORMATION 11 FIRMWARE UPGRADE BACKUP 12 Firmware Upgrade from HTTP 12 Firmware Upgrade from TFTP 12 Firmware Backup to HTTP 13 Firm...

Страница 4: ...ings 28 Time Zone Settings 29 SNTP SETTINGS 30 TIME PROFILE 31 5 MANAGEMENT 32 USER ACCOUNT SETTINGS 32 PASSWORD ENCRYPTION 33 SNMP 34 SNMP Global Settings 35 SNMP View Table Settings 36 SNMP Communit...

Страница 5: ...figuration Identification 71 STP Instance 72 MSTP Port Information 72 ERPS G 8032 73 ERPS 73 ERPS Profile 75 LOOPBACK DETECTION 77 LINK AGGREGATION 78 L2 MULTICAST CONTROL 81 IGMP Snooping 81 MLD Snoo...

Страница 6: ...ROL 100 Web Authentication 101 WAC Port Settings 102 WAC Customize Page 103 9 OAM 104 CABLE DIAGNOSTICS 104 DDM 105 DDM Settings 105 DDM Temperature Threshold Settings 106 DDM Voltage Threshold Settin...

Страница 7: ...ON 122 POE SCHEDULING 123 TIME 125 Clock Settings 125 SNTP Settings 125 SURVEILLANCE SETTINGS 126 SURVEILLANCE LOG 128 HEALTH DIAGNOSTIC 129 TOOLBAR 130 Wizard 130 Tools 130 Save 133 Help 134 Online H...

Страница 8: ...inciples for Local Area Networks Other Documentation The documents below are a further source of information in regards to configuring and troubleshooting the switch All the documents are available ei...

Страница 9: ...ent you should pay special attention to these indicators Each example below provides an explanatory remark regarding each type of indicator NOTE A note indicates important information that helps you m...

Страница 10: ...requests with MIB objects stored in the database The SNMP agent updates the MIB objects to generate statistics and counters Web based Management Interface After successfully installing the Switch the...

Страница 11: ...Password in the corresponding fields and click Login The default username is admin and the default password is admin This will open the Web based user interface The Switch s management features availa...

Страница 12: ...b mode specifically designed to assist the user with surveillance features supported by the Switch NOTE The Web Mode can only be changed when one user session is connected to the Web UI of the Switch...

Страница 13: ...nce Mode Web UI automatically The fields that can be configured are described below Parameter Description Static Select this option to manually configure and use IP address settings on this switch DHC...

Страница 14: ...word for the user account here Confirm Password Enter the new password again for confirmation here Tick the Ignore the wizard next time option to skip the Smart Wizard on the next login Click the Exit...

Страница 15: ...the SNMP function Select the Disabled option to disable the SNMP function Tick the Ignore the wizard next time option to skip the Smart Wizard on the next login Click the Exit button to discard the ch...

Страница 16: ...pen folders and click the hyperlinked window buttons and subfolders contained within them to display windows AREA 2 Presents Switch status based on user selection and the entry of configuration data I...

Страница 17: ...ders contained within them to display windows AREA 2 In this area configuration and monitoring window frames are available based on the selections made in area 1 AREA 3 Presents a toolbar used to acce...

Страница 18: ...he file system of the Switch This is to prevent the loss of configuration in the event of a power failure To view the following window click Save Save Configuration as shown below Click the Apply butt...

Страница 19: ...lick the Upgrade button to initiate the firmware upgrade Firmware Upgrade from TFTP This window is used to initiate a firmware upgrade from a TFTP server To view the following window click Tools Firmw...

Страница 20: ...e a firmware backup to a TFTP server To view the following window click Tools Firmware Upgrade Backup Firmware Backup to TFTP as shown below The fields that can be configured are described below Param...

Страница 21: ...and overwrite the start up configuration file on the Switch Click the Restore button to initiate the configuration restore Configuration Restore from TFTP This window is used to initiate a configurat...

Страница 22: ...from the Switch Exclude Username Password Specify this radio button to back up the running configuration file exclude username password from the Switch Click the Backup button to initiate the configu...

Страница 23: ...to initiate a system log backup to a TFTP server To view the following window click Tools Log Backup Log Backup to TFTP as shown below TThe fields that can be configured are described below Parameter...

Страница 24: ...imes desired to attempt to Ping the IPv4 address configured in this window Users may enter a number of times between 1 and 255 Tick the Infinite check box to keep sending ICMP Echo packets to the spec...

Страница 25: ...ude the IP address from being changed Select the The Switch will be reset to its factory defaults including IP address option to reset the Switch s configuration to its factory default settings Click...

Страница 26: ...tem Name System Location and System Contact to aid in defining the Switch To view the following window click System System Information Settings as shown below The fields that can be configured are des...

Страница 27: ...lected users can enter the IPv4 address of this interface manually in the fields provided When the DHCP option is selected this interface will obtain IPv4 information automatically from the DHCP serve...

Страница 28: ...n state is enabled IPv6 link local address will assigned to management VLAN automatically If state is disabled and static IPv6 address is not set the IPv6 feature will be disabled on switch Static IPv...

Страница 29: ...rough a cross over cable Cross Select this option for cross cabling If this option is selected the port is in the MDI mode and can be connected to a port in the MDIX mode on another switch through a s...

Страница 30: ...e size of up to 9600 bytes To view the following window click System Port Configuration Jumbo Frame as shown below The fields that can be configured are described below Parameter Description From Port...

Страница 31: ...circuit protection automatically disables the port if there is a short Other ports will remain active Based on 802 3af at PDs receive power according to the following classification PSE provides power...

Страница 32: ...ew the following window click System PoE PoE Configuration as shown below The fields that can be configured are described below Parameter Description From Port To Port Select the appropriate port rang...

Страница 33: ...nction on the specified port s PD IP Address Enter the IP address of the PD here Poll Interval Enter the poll interval here This is the interval between ping messages from the system to PDs connected...

Страница 34: ...escribed below Parameter Description Buffer Log State Select whether the enable or disable the buffer log s global state Click the Apply button to accept the changes made System Log Server Settings Th...

Страница 35: ...ge when multiple pages exist Time and SNTP The Simple Network Time Protocol SNTP is a protocol for synchronizing computer clocks through the Internet It provides comprehensive mechanisms to access nat...

Страница 36: ...tting and Date Setting Disabled Select to disable the summer time setting Recurring Setting Select to configure the summer time that should start and end on the specified week day of the specified mon...

Страница 37: ...f the month that summer time will start From Month Select the month that summer time will start From Year Enter the year that the summer time will start From Time HH MM Select the time of the day that...

Страница 38: ...ing window click System Time Profile as shown below The fields that can be configured are described below Parameter Description Range Name Enter the name of the time range This name can be up to 32 ch...

Страница 39: ...his administrator user account level can monitor all system information and change any of the system configuration settings expressed in this guide To view the following window click Management User A...

Страница 40: ...iew the following window click Management Password Encryption as shown below The fields that can be configured are described below Parameter Description Password Encryption State Choose the enable or...

Страница 41: ...s The first part is to maintain a list of users and their attributes that are allowed to act as SNMP managers The second part describes what each user on that list can do as an SNMP manager The Switch...

Страница 42: ...obal Settings as shown below The fields that can be configured for SNMP Global Settings are described below Parameter Description SNMP Global State Select this option to enable or disable the SNMP fea...

Страница 43: ...Settings as shown below The fields that can be configured are described below Parameter Description View Name Type an alphanumeric string of up to 32 characters This is used to identify the new SNMP v...

Страница 44: ...s used to identify members of an SNMP community This string is used like a password to give remote SNMP managers access to MIB objects in the Switch s SNMP agent View Name Enter an alphanumeric string...

Страница 45: ...Pv2c and SNMPv3 SNMPv1 Select to allow the group user to use the SNMPv1 security model SNMPv2c Select to allow the group user to use the SNMPv2c security model SNMPv3 Select to allow the group user to...

Страница 46: ...Engine ID is a unique identifier used for SNMP V3 implementations on the Switch To view the following window click Management SNMP SNMP Engine ID Local Settings as shown below The fields that can be...

Страница 47: ...entication level This field will require the user to enter a password or a key SHA Specify that the HMAC SHA authentication protocol will be used This field will require the user to enter a password o...

Страница 48: ...lable NoAuthNoPriv Specify that there will be no authorization and no encryption of packets sent between the Switch and a remote SNMP manager AuthNoPriv Specify that authorization will be required but...

Страница 49: ...nges made RMON Statistics Settings This window is used to configure and display the RMON statistics on the specified port To view the following window click Management RMON RMON Statistics Settings as...

Страница 50: ...35 Bucket Number Enter Specifies the number of buckets specified for the RMON collection history group of statistics The range is from 1 to 65535 The default value is 50 Interval Enter the time in sec...

Страница 51: ...ng Threshold Enter the rising threshold value between 0 and 2147483647 Falling Threshold Enter the falling threshold value between 0 and 2147483647 Rising Event Number Enter the index of the event ent...

Страница 52: ...pe Options to choose from are None Log Trap and Log and Trap Community Enter the community string The string can be up to 127 characters Owner Enter the owner string The string can be up to 127 charac...

Страница 53: ...ick the Apply button to accept the changes made D Link Discovery Protocol This window is used to configure and display D Link Discovery Protocol DDP To view the following window click Management D Lin...

Страница 54: ...bed below Parameter Description Port Allows the selection of the port number on which the MAC address entered resides VID Enter the VLAN ID on which the associated unicast MAC address resides MAC Addr...

Страница 55: ...ck the Delete All button to remove all the entries Click the Delete button to remove the specific entry Enter a page number and click the Go button to navigate to a specific page when multiple pages e...

Страница 56: ...disable the MAC address learning function on the ports specified here Click the Apply button to accept the changes made MAC Address Table This window is used to view the entries listed in the MAC add...

Страница 57: ...LAN Configuration Wizard as shown below The fields that can be configured are described below Parameter Description Create VLAN VID Select and enter a new VLAN ID Configure VLAN VID Select and enter a...

Страница 58: ...Click to allow an individual port to be specified as a non VLAN member Click the All button to select all ports Native VLAN PVID Click to designate the port as native VLAN Click the All button to sele...

Страница 59: ...e Click the Delete button to remove the specific entry Click the Edit button to re configure the specific entry Enter a page number and click the Go button to navigate to a specific page when multiple...

Страница 60: ...N creation function here Join Time Enter the Join Time value in centiseconds This value must be between 1 and 20 centiseconds By default this value is 20 centiseconds Leave Time Enter the Leave Time v...

Страница 61: ...o accept the changes made GVRP Advertise VLAN This window is used to view and configure the GVRP advertised VLAN settings To view the following window click L2 Features VLAN GVRP GVRP Advertise VLAN a...

Страница 62: ...GVRP Forbidden VLAN as shown below The fields that can be configured are described below Parameter Description From Port To Port Select the appropriate port range used for the configuration here Acti...

Страница 63: ...tric VLAN function Click the Apply button to accept the changes made VLAN Interface This window is used to view and configure VLAN interface settings To view the following window click L2 Features VLA...

Страница 64: ...ss Hybrid and Trunk Acceptable Frame Select the acceptable frame behavior option here Options to choose from are Tagged Only Untagged Only and Admit All Ingress Checking Select this option to enable o...

Страница 65: ...gged or Tagged parameters Allowed VLAN Range Enter the allowed VLAN range information here Click the Apply button to accept the changes made Click the Back button to return to the previous window When...

Страница 66: ...een 1 and 4094 Action Select the action that will be taken here Options to choose from are All Add Remove and Except Allowed VLAN Range Enter the allowed VLAN range information here Click the Apply bu...

Страница 67: ...ue is 720 minutes The aging time is used to remove a port from surveillance VLAN if the port is an automatic surveillance VLAN member When the last surveillance device stops sending traffic and the MA...

Страница 68: ...tion To view the following window click L2 Features VLAN Auto Surveillance VLAN MAC Settings and Surveillance Device as shown below The fields that can be configured are described below Parameter Desc...

Страница 69: ...ion Click the Edit button to configure the state and description of the IP camera After click the More Detail button the following window will appear Guide After click the Edit button the following wi...

Страница 70: ...ew the list of IP cameras that are connected to the NVR Click the Edit button to configure the description of the NVR Guide After click the IP Camera List button the following window will appear Click...

Страница 71: ...Parameter Description Voice VLAN State Select this option to enable or disable the voice VLAN Voice VLAN ID Enter the voice VLAN ID The value is range from 2 to 4094 Voice VLAN CoS Select the priority...

Страница 72: ...tion From Port To Port Select the appropriate port range used for the configuration here State Select this option to enable or disable the state of the port Mode Select the mode of the port Options to...

Страница 73: ...ow Parameter Description OUI Address Enter the OUI MAC address Mask Enter the OUI MAC address matching bitmask Description Enter the description for the user defined OUI with a maximum of 32 character...

Страница 74: ...and full processing of frames regardless of administrative errors in defining VLANs and their respective spanning trees Each switch utilizing the MSTP on a network will have a single MSTP configuratio...

Страница 75: ...ges 802 1Q 2005 MSTP 802 1D 2004 RSTP 802 1D 1998 STP Forwarding Learning Disabled Disabled Disabled No No Discarding Discarding Blocking No No Discarding Discarding Listening No No Learning Learning...

Страница 76: ...on STP Mode Select the STP mode used here Options to choose from are MSTP RSTP and STP Click the Apply button to accept the changes made The fields that can be configured for STP Traps are described b...

Страница 77: ...propriate port range used for the configuration here Port Fast Select the port fast option here Options to choose from are Network Disabled and Edge In the Network mode the port will remain in the non...

Страница 78: ...will show the MAC address to the device running MSTP Revision Level Enter the revision level value here This value must be between 0 and 65535 By default this value is 0 This value along with the Conf...

Страница 79: ...exist MSTP Port Information This window is used to view and configure the MSTP port information settings To view the following window click L2 Features Spanning Tree MSTP Port Information as shown be...

Страница 80: ...ton the following window will appear The fields that can be configured are described below Parameter Description Instance ID Select the checkbox and enter the ERP instance number here This value must...

Страница 81: ...annel VLAN Select the checkbox and enter the R APS channel VLAN s ID for the ERP instance here The APS channel VLAN of a sub ring instance is also the virtual channel of the sub ring This value must b...

Страница 82: ...lect the checkbox and then select the RPL port option here Options to choose from are Port0 and Port1 The option selected will be configured as the RPL port RPL Role Select the checkbox and then selec...

Страница 83: ...l appear The fields that can be configured are described below Parameter Description Revertive Select the checkbox and then select the revertive state Options to choose from are Enable and Disabled Th...

Страница 84: ...Loopback Detection Select to enable or disable loopback detection The default is Disabled Time Interval Enter the interval in seconds that the device will transmit all the CTP Configuration Test Prot...

Страница 85: ...a multiple of a single link s bandwidth Link aggregation is most commonly used to link a bandwidth intensive network device or devices such as a server to the backbone of a network The Switch allows...

Страница 86: ...are described below Parameter Description From Port To Port Select the appropriate port range used for the configuration here Group ID Enter the channel group number here This value must be between 1...

Страница 87: ...Industrial Gigabit Ethernet Smart Managed Switch 80 After clicking the Channel Detail button the following page will be available Click the Back button to return to the previous window Figure 6 50 Por...

Страница 88: ...ssages sent from the device to the IGMP host or vice versa The Switch monitors IGMP messages and discontinues forwarding multicast packets when there are no longer hosts requesting that they continue...

Страница 89: ...nooping Groups Settings This window is used to configure and view the IGMP snooping static group and view IGMP snooping group To view the following window click L2 Features L2 Multicast Control IGMP S...

Страница 90: ...age is sent by the router to ask if any link is requesting multicast data There are two types of MLD query messages emitted by the router The General Query is used to advertise all multicast addresses...

Страница 91: ...nter a VLAN ID from 1 to 4094 and select to enable or disable MLD snooping on the VLAN Click the Apply button to accept the changes made The fields that can be configured for VLAN Querier Status Setti...

Страница 92: ...gate to a specific page when multiple pages exist Multicast Filtering This window is used to view and configure the Layer 2 multicast filtering settings To view the following window click L2 Features...

Страница 93: ...is option to enable or disable the LLDP feature LLDP Trap State Select this option to enable or disable the LLDP trap state Click the Apply button to accept the changes made LLDP Neighbor Port Informa...

Страница 94: ...fied port s Options to choose from are Strict Priority SP and Weighted Round Robin WRR By default the output queue scheduling algorithm is WRR To set a CoS queue in the SP mode any higher priority CoS...

Страница 95: ...ade Port Rate Limiting This window is used to view and configure the port scheduler method settings To view the following window click QoS Port Rate Limiting as shown below The fields that can be conf...

Страница 96: ...Select the port trust state option here Options to choose from are CoS and DSCP Click the Apply button to accept the changes made DSCP CoS Mapping This window is used to view and configure the DSCP Co...

Страница 97: ...to the Switch prior to locking the port or ports from connecting to the Switch s locked ports and gaining access to the network To view the following window click Security Port Security Port Security...

Страница 98: ...y default this value is 32 Violation Action Select the violation action that will be taken here Options to choose from are Protect Restrict and Shutdown Selecting Protect specifies to drop all packets...

Страница 99: ...shown below The fields that can be configured are described below Parameter Description Port Select the port used for the configuration here MAC Address Enter the MAC address here Click the Clear by...

Страница 100: ...processing time by setting the dead time to skip the unresponsive server host entries When the system performs authentication with the authentication server it attempts one server at a time If the at...

Страница 101: ...retransmit value used here This value must be between 0 and 20 By default this value is 3 To disable this option enter the value 0 Timeout Enter the timeout value used here This value must be between...

Страница 102: ...itch by minimizing the workload of the Switch while the attack is ongoing thus making it capable to forward essential packets over its network in a limited bandwidth Safeguard Engine Settings This win...

Страница 103: ...l will be included in the forwarding domain If the forwarding domain of an interface is empty then there is no restriction on Layer 2 forwarding of packets received by the port To view the following w...

Страница 104: ...n mode the unicast refers to both known and unknown unicast packets that is if the known and unknown unicast packets hit the specified threshold the port will be shutdown Otherwise unicast refers to u...

Страница 105: ...t scanning by using specific packets which contain source port 0 to 1023 and SYN flag Ping Death Attack A ping of death is a type of attack on a computer that involves sending a malformed or otherwise...

Страница 106: ...efense settings To view the following window click Security Zone Defense Settings as shown below The fields that can be configured for Zone Defense Settings are described below Parameter Description Z...

Страница 107: ...urity features is an essential tool in today s networking environment It is a powerful guardian against numerous existing security hazards that now threaten network communications SSH Global Settings...

Страница 108: ...ich will determine a Message Authentication Code This Message Authentication Code will be encrypted with a sent message to provide integrity and prevent against replay attacks The Switch supports two...

Страница 109: ...L feature s global status here Click the Apply button to accept the changes made The fields that can be configured for Import File are described below Parameter Description Key Select the Key file tha...

Страница 110: ...IP is transformed into the physical IPIF IP interface address of the Switch to make the communication possible The host PC and other servers IP configurations do not depend on the virtual IP of WAC T...

Страница 111: ...uthentication is just the characterization of the Web authentication function on the Switch All Web authentication processes communicate with this IP address however the virtual IP does not respond to...

Страница 112: ...Port Settings as shown below The fields that can be configured are described below Parameter Description Unit Select the switch unit that will be used for this configuration here From Port To Port Sel...

Страница 113: ...e can be up to 64 characters long User Name Title Enter a custom username title here This title can be up to 32 characters long Password Title Enter a custom password title here This title can be up t...

Страница 114: ...Diagnostics as shown below The fields that can be configured are described below Parameter Description From Port To Port Select the appropriate port range used for the configuration here Click the Tes...

Страница 115: ...below The fields that can be configured are described below Parameter Description Transceiver Monitoring Traps Alarm Select this option to enable or disable sending alarm level trap Transceiver Monit...

Страница 116: ...e action that will be taken here Options to choose from are Add and Delete Type Select the type of temperature threshold Options to choose from are Low Alarm Low Warning High Alarm and High Warning Va...

Страница 117: ...Current Threshold Settings This window is used to configure the threshold of the bias current for specific ports on the Switch To view the following window click OAM DDM DDM Bias Current Threshold Se...

Страница 118: ...o choose from are Low Alarm Low Warning High Alarm and High Warning Power Unit Select the power unit here Options to choose from are mW and dBm Value Enter the threshold value When selecting mW in the...

Страница 119: ...r Unit Select the power unit here Options to choose from are mW and dBm Value Enter the threshold value When selecting mW in the Power Unit drop down list this value must be between 0 and 6 5535 When...

Страница 120: ...ow The fields that can be configured are described below Parameter Description From Port To Port Select the appropriate port range used for the configuration here Click the Find button to locate a spe...

Страница 121: ...described below Parameter Description Destination Select the destination switch s port number Source From the From Port drop down menu select the starting port number and from the To Port drop down m...

Страница 122: ...status is link up Scheduled Port shutdown Power Saving Select this option to enable or disable applying the power saving by scheduled port shutdown Scheduled Hibernation Power Saving Select this opti...

Страница 123: ...tab the following page will appear The fields that can be configured are described below Parameter Description From Port To Port Select the appropriate port range used for the configuration here Time...

Страница 124: ...o packets are being sent To view the following window click Green EEE as shown below The fields that can be configured are described below Parameter Description From Port To Port Select the appropriat...

Страница 125: ...lly when you access the Surveillance Mode in the Web UI of the Switch Surveillance Topology This window provides more information about what is connected to each port Hover with the mouse pointer over...

Страница 126: ...nt of other devices connected to the Ethernet ports on the Switch This displays the device connected to the Ethernet port on the Switch The green border around the image indicates that the device is a...

Страница 127: ...on that will be taken here Options to choose from are Reset Notify and Both Reset Specifies to reset the PoE port state turn PoE off and on Notify Specifies to send logs and traps to notify the admini...

Страница 128: ...VIF traffic to monitor the status of the surveillance device but some third party devices do not fully comply with the ONVIF standard If you are having problems with surveillance devices not being det...

Страница 129: ...evices connected to the Ethernet ports on the Switch This displays the total amount of ONVIF IP cameras connected to the Ethernet ports on the Switch This displays the total amount of NVRs connected t...

Страница 130: ...can be selected Options to choose from are Video Management Server VMS Client Remote Viewer Video Encoder Network Storage and Other IP Surveillance Device Group Details After clicking Group Details l...

Страница 131: ...of ONVIF IP cameras connected to the Ethernet ports on the Switch The displays the total power consumption and power class of PDs used by the ONVIF IP cameras connected to the Ethernet ports on the Sw...

Страница 132: ...Information This window is used to display NVR information To view the following window click NVR Information as shown below Guide The following icons are available in this window and are described be...

Страница 133: ...mation about the ONVIF IP camera that is managed by this NVR PoE Information This window is used to display Power over Ethernet PoE information Guide To view the following window click PoE Information...

Страница 134: ...PoE budget available on this port This displays the current PoE status on the port This status can be one of the following Searching Delivering or Power Denied When the Power Denied message is displa...

Страница 135: ...Apply button to accept the changes made Click the Delete button to remove the specified entry Enter a page number and click the Go button to navigate to a specific page when multiple pages exist The...

Страница 136: ...scribed below Parameter Description Time HH MM SS Enter the current time in hours minutes and seconds Date DD MM YYYY Enter the current day month and year to update the system clock Click the Apply bu...

Страница 137: ...erver Setting section are described below Parameter Description IPv4 Address Enter the IPv4 address of the SNTP server here Click the Add button to add the SNTP server to the configuration Click the D...

Страница 138: ...dress of the Switch here Mask Enter the IPv4 subnet mask of the Switch here Gateway Enter the IPv4 address of the default gateway here Click the Apply button to accept the changes made The fields that...

Страница 139: ...anges made Click the Delete button to remove the specified entry Surveillance Log This window is used to display the surveillance log To view the following window click Surveillance Log as shown below...

Страница 140: ...This field displays the Ethernet port number Loopback Detection Status This field displays the Loopback Detection status on the Ethernet port It can be one of the following Normal No loop is detected...

Страница 141: ...to initiate a cable distance test on all the ports of the Switch Toolbar Wizard Click this option to start the Smart Wizard For more information about the Smart Wizard refer to Smart Wizard on page 4...

Страница 142: ...ow is used to initiate a firmware backup to a local PC using HTTP To view the following window click Tools Firmware Upgrade Backup Firmware Backup to HTTP as shown below The fields that can be configu...

Страница 143: ...to initiate the configuration restore Configuration Restore from HTTP This window is used to initiate a configuration file backup to a local PC using HTTP To view the following window click Tools Conf...

Страница 144: ...default settings Click the Apply button to initiate the factory default reset and reboot the Switch Reboot System This window is used to reboot the Switch and alternatively save the configuration bef...

Страница 145: ...hernet Smart Managed Switch 134 Help Click this option to access the built in Surveillance Help window Guide After clicking the Help option the following window will appear Figure 12 27 Help Diagram w...

Страница 146: ...tch An Internet connection is required Standard Mode Click the Standard Mode button in the toolbar to change the Web UI mode and style from Surveillance Mode to Standard Mode NOTE All active Web UI us...

Страница 147: ...nterface id Interface name vid VLAN ID Informational Event description When an interface leaves the surveillance VLAN and at the same time no surveillance device is detected in the aging interval for...

Страница 148: ...ion When an NVR is added in the surveillance VLAN the log message will be sent Log Message ASV Add NVR IP ipaddr MAC mac address Parameters description ipaddr Represent the IP address of the NVR mac a...

Страница 149: ...reshold Log Message Optical transceiver interface id component back to normal Parameters description interface id port interface ID component DDM threshold type It can be one of the following types te...

Страница 150: ...scription username Represent current login user Informational vent description Login through console unsuccessfully Log Message Login failed through Console Username username Parameters description us...

Страница 151: ...t through Telnet Username username IP ipaddr Parameters description username Represent current login user ipaddr Represent client IP address Informational PoE Log Description Severity Event descriptio...

Страница 152: ...uard Log Description Severity Event description the host enters the mode of exhausted Log Message Unit unit id Safeguard Engine enters EXHAUSTED mode Parameters description unit id The Unit ID Warning...

Страница 153: ...ipaddr Parameters description ipaddr The IP address of telnet client username the user name that used to login telnet server Informational Event description Telnet session timed out Log Message Telnet...

Страница 154: ...The use name that used to login HTTP server ipaddr The IP address of HTTP client Informational Event description Login failed through Web Log Message Login failed through Web Username username IP ipad...

Страница 155: ...ddress mac address The host MAC addresses interface id The interface on which the host is authenticated vlan id The VLAN ID on which the host exists Informational Event description When a host fail to...

Страница 156: ...erated 1 3 6 1 6 3 1 1 5 5 DDM Trap Name Description OID dDdmAlarmTrap A notification is generated when an abnormal alarm situation occurs or recovers from an abnormal alarm situation to normal status...

Страница 157: ...angeTime changes It can be utilized by an NMS to trigger LLDP remote systems table maintenance polls Binding objects 1 lldpStatsRemTablesInserts 2 lldpStatsRemTablesDeletes 3 lldpStatsRemTablesDrops 4...

Страница 158: ...er 1 3 6 1 2 1 105 0 2 pethMainPowerUsageOff Notification This trap indicates PSE Threshold usage indication is off the usage power is below the threshold At least 500 msec must elapse between notific...

Страница 159: ...scription OID coldStart A coldStart trap signifies that the SNMPv2 entity acting in an agent role is reinitializing itself and that its configuration may have been altered 1 3 6 1 6 3 1 1 5 1 warmStar...

Страница 160: ...nAuthUserName isWebAuthLoggedFail The trap is sent when a host has failed to pass Web Authentication login failed Binding objects 1 ifIndex 2 isnaSessionAuthVlan 3 isnaSessionClientMacAddress 4 isnaSe...

Страница 161: ...tch RADIUS attributes are supported by the IETF standard and Vendor Specific Attribute VSA VSA allows the vendor to create an additionally owned RADIUS attribute IETF standard RADIUS attributes are de...