After a device is inserted into the rack, carefully extend the rail into a locking position, and then slide the device 
into the rack. 

 

Do not overload the AC supply branch circuit that provides power to the rack. The total rack load should not 
exceed 80 percent of the branch circuit rating. 

 

Ensure that proper airflow is provided to components in the rack. 

 

Do not step on or stand on any component when servicing other components in a rack. 

NOTE:

 

A qualified electrician must perform all connections to DC power and to safety grounds. All 

electrical wiring must comply with applicable local or national codes, standards and practices.

 

 

 

 

CAUTION:

 Never override the ground conductor or operate the equipment in the absence of a suitably 

installed ground conductor.  

Contact the appropriate electrical inspection authority or an electrician if uncertain that suitable 
grounding is available. 

 

 

 

CAUTION:

 The system chassis must be positively grounded to the rack cabinet frame. Do not attempt 

to connect power to the system until grounding cables are connected. Completed power and safety ACL 
Profile List Page  ground wiring must be inspected by a qualified electrical inspector. An energy hazard 
exists if the safety ground cable is omitted or disconnected. 

Protecting Against Electrostatic Discharge  

Static electricity can harm delicate device components. To prevent static damage, discharge static electricity before touching 
any of the electronic components, such as the microprocessor. 

To discharge static electricity:  

 

Make contact by touching an unpainted metal surface on the chassis. 

 

Handle all sensitive components in a static-safe area. If possible, use antistatic floor pads and workbench pads, and 
an antistatic grounding strap. 

 

Do not remove the component from the antistatic packing material until you are ready to install the system 
component. Just before unwrapping the antistatic packaging, discharge static electricity from your body.  

 

Place all sensitive components in antistatic containers or packaging when transporting. 

Battery Handling Reminder 

 

 

CAUTION:

 The battery can explode if incorrectly replaced. Only replace batteries with the same or 

equivalent type recommended by the manufacturer. Discard used batteries in accordance with the 
manufacturer's instructions. 

11 

Содержание DGS-3100 SERIES

Страница 1: ...D Link DGS 3100 SERIES GIGABIT STACKABLE MANAGED SWITCH Hardware Installation Guide V2 20...

Страница 2: ...ed and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in whi...

Страница 3: ...evice on a Rack 12 Powering on the Device 14 Using the External Redundant Power Supply 15 Web Based Network Management 16 Login to Web Manager 16 Using the Web Based User Interface 17 Understanding th...

Страница 4: ...TP Server 35 Security Management and Password Configuration 36 Software Download Through TFTP Server 37 Boot Image Download 38 Restore Default Button 39 DEVICE SPECIFICATIONS 40 Technical Specificatio...

Страница 5: ...de i Preface This preface provides an overview to the guide and includes the following sections System Overview Device Management Methods Installation Guide Overview Intended Audience Notes Notices an...

Страница 6: ...connect fiber optic media to switches servers or network back bones The DGS 3100 Series provides an additional RS 232 DEC Diagnostic port console port for managing the switch via a console terminal or...

Страница 7: ...twork management concepts and terminology Notes Notices and Cautions NOTE A NOTE indicates important information that helps you make better use of your device NOTICE A NOTICE indicates either potentia...

Страница 8: ...chase a power cable that is approved for use in your country The power cable must be rated for the product and for the voltage and current marked on the product s electrical ratings label The voltage...

Страница 9: ...m up and load the heaviest item in the rack first Make sure that the rack is level and stable before extending a component from the rack Use caution when pressing the component rail release latches an...

Страница 10: ...also take the following steps to prevent damage from electrostatic discharge ESD 1 When unpacking a static sensitive component from its shipping carton do not remove the component from the antistatic...

Страница 11: ...1 2 DGS 3100 48 Port Front Panel View Figure 1 2 DGS 3100 24TG Front Panel View Comprehensive LED indicators display the status of the switch and the network see the LED Indicators section below Eight...

Страница 12: ...y connector is used to connect the DGS 3100 Series to one of the following supported units DGS 3100 Series Device Supported RPS Unit DGS 3100 24 DPS 300 DGS 3100 48 DPS 500 DGS 3100 24P 48P DPS 600 DG...

Страница 13: ...ns dissipate heat and the heat vents located on the sides serve the same purpose The openings must remain clear of obstructions Ensure there is at least 6 inches of clear space at the rear and sides o...

Страница 14: ...dicator is a solid green light when the system is powered up and remains dark when the system is off Console This indicator flashes green when the system is booting up It remains solid green when the...

Страница 15: ...function is enabled from user interface Stacking ID Green Light off Indicates the device is in stand alone mode Solid Light A valid link is established on the stacking HX port Flashing Data transmissi...

Страница 16: ...e is in stand alone mode Solid Light A LED Mode Select Button to switch Link Act Speed Mode Port LED Mode Indicator Green Solid Light A LED Mode Select Button to switch PoE Mode Solid Light A valid li...

Страница 17: ...1 6 Display the Stacking Unit ID Flashing Character L Locates the master unit when the locator function is enabled from user interface Stacking ID Green Light off Indicates the device is in stand alon...

Страница 18: ...Series Before beginning the Installation and Configuration process see Safety Instructions This section contains the following topics Unpacking the Device Safety Instructions General Precautions for...

Страница 19: ...the system documentation Opening or removing covers that are marked with a lightning bolt enclosed by a triangular symbol potentially exposes you to electrical shock Only a trained service technician...

Страница 20: ...power company for site modifications Always follow the local national wiring standards When connecting or disconnecting power to hot pluggable power supplies if offered with the device observe the fo...

Страница 21: ...to the system until grounding cables are connected Completed power and safety ACL Profile List Page ground wiring must be inspected by a qualified electrical inspector An energy hazard exists if the...

Страница 22: ...ng topics Installing the Device on a Desktop or Shelf Installing the Device on a Rack Installing the Device on a Desktop or Shelf When installing the DGS 3100 Series device on a desktop or shelf the r...

Страница 23: ...Stackable Managed Switch Hardware Installation Guide Figure 2 2 Attaching the Mounting Brackets 3 Use the screws provided with the equipment rack to mount the switch on the rack Figure 2 3 Installing...

Страница 24: ...ged in All LED indicators except console momentarily flash Flashing LEDs indicate the system is being reset The console LED indicators flash while the device loads software and performs a self test Wh...

Страница 25: ...t Power Supply The device supports an external Redundant Power Supply Figure 2 4 DPS 500 in DPS 900 Chassis Figure 2 5 DPS 500 in DPS 800 Chassis CAUTION Do not use the device with any Redundant Power...

Страница 26: ...in the console program NOTE This Web based Management module does not accept Chinese language input or other languages requiring 2 bytes per character NOTE The Web browser needs to be upgraded to the...

Страница 27: ...he D Link Embedded Web Interface The D Link Embedded Web Interface Device Information Page contains the following information Tree View Displays the different system features and configuration options...

Страница 28: ...ge of the front panel of the Switch This area displays the Switch s ports showing port activity duplex mode or flow control depending on the specified mode Various areas of the graphic can be selected...

Страница 29: ...GURING THE DEVICE This chapter describes how to connect the DGS 3100 Series to a Gigabit Ethernet network This section includes the following topics Connecting to an End Node Connecting to HUB or Swit...

Страница 30: ...routers An end node can be connected to the switch via a Category 3 4 5 or 5e UTP STP cable For optimal performance Category 5e cables are recommended The end node should be connected to any of the d...

Страница 31: ...e different port types using A 10BASE T HUB or switch is to the switch via a two pair Category 3 4 5 or 5e UTP STP cable A 100BASE TX HUB or switch is connected to the switch via a two pair Category 5...

Страница 32: ...screws 3 Connect the other end of the cable to a terminal or to the serial connector of a computer running terminal emulation software Set the terminal emulation software as follows 1 Select either se...

Страница 33: ...PASS Flash Image Validation Test PASS BOOT Software Version 1 0 0 0 Built 04 Mar 2007 12 42 48 Network Switch based on 88E6218 with ARM946E S 64MByte SDRAM I Cache 8 KB D Cache 8 KB Cache Enabled Aut...

Страница 34: ...01 58 Box I SFP PRESENT CHNG unit_id 1 SFP 0 status is not present 01 Jan 2000 01 01 58 Box I SFP PRESENT CHNG unit_id 1 SFP 1 status is not present 01 Jan 2000 01 01 58 Box I SFP PRESENT CHNG unit_id...

Страница 35: ...access privileges For more information on assigning administration access levels see Security Management and Password Configuration For the complete CLI list see the DGS 3100 Series Managed Switch CL...

Страница 36: ...by the device the Ring topology or Chain topology Figure 3 6 Connecting the Device in a Stack The device is Plug and Play in terms of stacking connection and configuration Before powering up the devic...

Страница 37: ...lems occur while connecting to the PC ensure the emulation is set to VT 100 To set the emulation select File Properties Settings tab in the HyperTerminal window The Emulation options are displayed in...

Страница 38: ...ter completing all external connections connect a terminal to the device to monitor the boot and other procedures This section contains information for configuring initial device including Booting the...

Страница 39: ...SDRAM PASS Boot1 Checksum Test PASS Boot2 Checksum Test PASS Flash Image Validation Test PASS BOOT Software Version 1 0 0 0 Built 01 Feb 2007 14 05 13 Network Switch based on 88E6218 with ARM946E S 64...

Страница 40: ...ational 01 Jan 2000 01 04 02 Entity I SEND ENT CONF CHANGE TRAP entity configuration change trap 01 Jan 2000 01 04 02 Box W PS STAT CHNG PS 1 status is not operational Configuration Overview Before as...

Страница 41: ...ing configuration items loaded 0 01 Jan 2000 01 04 01 SNMP I CDBITEMSNUM Number of startup configuration items loaded 0 01 Jan 2000 01 04 02 Box A FAN STAT CHNG FAN 1 status is not operational 01 Jan...

Страница 42: ...provide a standard presentation of the information controlled by the on board SNMP agent SNMP defines both the MIB specification format and the protocol used to access this information over the networ...

Страница 43: ...S3100 sh snmp community Community Name View name Access Right Access Default read write Tony Default read write Total Entries 2 DGS3100 create snmp host 100 1 1 3 v1 Tony DGS3100 show snmp host SNMP H...

Страница 44: ...a DHCP server 1 Select and connect any port to a DHCP server or to a subnet that has a DHCP server on it in order to retrieve the IP address 2 Enter the following commands to use the selected port for...

Страница 45: ...ystem prompt enter the delete startup configuration command to delete the startup configuration from flash The device reboots with no configuration and in 60 seconds starts sending BOOTP requests The...

Страница 46: ...with the privilege level of USER is allowed only to view the configuration whereas a user with a privilege level of ADMIN is allowed to change the configuration as well as viewing it Without a passwo...

Страница 47: ...w version to verify which software version is currently running on the device The following is an example of the information that appears DGS31000 show version SW version x xx xx date xx xxx 2004 time...

Страница 48: ...y which boot shift is currently running on the device The following is an example of the information that appears DGS31000 show shift SW version x xx xx date xx xxx 2004 time 13 42 41 Boot version x x...

Страница 49: ...lt Settings This section contains instructions for restoring default settings A Restore Default Button that is used to restore default settings To restore defaults settings the button must be held dow...

Страница 50: ...30 seconds Default 300 Physical and Environmental AC Inputs 100 240 VAC 50 60 Hz internal universal power supply Power Consumption 1 DGS 3100 24P 126W For system power 370W For POE power 2 DGS 3100 24...

Страница 51: ...ters max 100BASE TX UTP Cat 5 100 meters max EIA TIA 568 150 ohm STP 100 meters max 1000BASE T UTP Cat 5e 100 meters max UTP Cat 5 100 meters max EIA TIA 568B 150 ohm STP 100 meters max 1000BASE LX Si...

Страница 52: ...gths Standard Media Type Maximum Distance Mini GBIC DEM 310GT SFP Transceiver for 1000BASE LX Single mode fiber module 10km DEM 311GT SFP Transceiver for 1000BASE SX Multi mode fiber module 550m 1000B...

Страница 53: ...roadcasts that typically absorb available network bandwidth and can cause network failure console port The port on the Switch accepting a terminal It changes the parallel arrangement of data within co...

Страница 54: ...ized location serving a large user population SLIP Serial Line Internet Protocol A protocol that allows IP to run over a serial line connection SNMP Simple Network Management Protocol A protocol origi...

Отзывы: