DGS-1100-06/ME Metro Ethernet Managed Switch CLI Reference Guide
22
address then
‘echos’ or returns the message. This is used to confirm
connectivity between the Switch and the remote device.
Parameters
<ipaddr>
- The IP address of the host.
times <value 1-255>
- The number of individual ICMP echo
messages to be sent. The maximum value is 255. The default is 4.
timeout <sec 1-99>
- The time-out period while waiting for a
response from the remote device. A value of 1 to 99 seconds can be
specified. The default is 1 second.
size <short 0-2080> -
Specify the size of the test packet. A value of
0 to 2080 can be specified.
Restrictions
None.
Example usage:
To ping the IP address 10.6.150.34 three times:
DGS-1100-06/ME:5#ping 10.6.150.34 times 3
Command: ping 10.6.150.34 times 3
Reply Not Received From : 10.6.150.34, Timeout : 5 secs
Reply Not Received From : 10.6.150.34, Timeout : 5 secs
Reply Not Received From : 10.6.150.34, Timeout : 5 secs
--- 10.6.150.34 Ping Statistics ---
3 Packets Transmitted, 0 Packets Received, 100% Packets Loss
DGS-1100-06/ME:5#
ping6
Purpose
To test the IPv6 connectivity between network devices.
Syntax
ping6 <ipv6_addr> {frequency <sec 0-86400> | size <value 1-
1522> | source_ip <ipv6_addr> | timeout <sec 1-99> | times
<value 1-255>}
Description
The
ping6
command sends IPv6 Internet Control Message Protocol
(ICMP) echo messages to a remote IPv6 address. The remote IPv6
address will then “echo” or return the message. This is used to
confirm the IPv6 connectivity between the switch and the remote
device.
Parameters
<ipv6_addr>
- The IPv6 address of the host.
frequency <sec 0-86400> -
The number of seconds to wait before
repeating a ping test as defined by the value of this parameter.
A single ping test consists of a series of ping probes. The number of
probes is determined by the value of the parameter times. After a
single test completes the number of seconds as defined by the value
of frequency must elapse before the next ping test is started.
A value of 0 for this parameter implies that the test as defined by the
corresponding entry will not be repeated.
size <value 1-1522> -
Specify the size of the test packet. A value of
1 to 1522 can be specified.
source_ip <ipv6_addr > -
Specify the source IPv6 address of the
ping packets. If specified this parameter, this IPv6 address will be
used as the packets’ source IPv6 address that ping6 sends to the
remote host.
Содержание DGS-1100-06/ME
Страница 1: ...D Link DGS 1100 06 MEVer A1 MetroEthernetManagedSwitch CLI Reference Guide V1 0 ...
Страница 2: ......
Страница 132: ...DGS 1100 06 ME Metro Ethernet Managed Switch CLI Reference Guide 120 Success DGS 1100 06 ME 5 ...
Страница 178: ...DGS 1100 06 ME Metro Ethernet Managed Switch CLI Reference Guide 166 Total Entries 0 DGS 1100 06 ME 5 ...
Страница 273: ...DGS 1100 06 ME Metro Ethernet Managed Switch CLI Reference Guide 261 ...