background image

D-Link DGS-1005D Unmanaged Gigabit Ethernet Switch

 

vi 

 

When connecting or disconnecting power to hot-pluggable power supplies, if offered with your system, observe 
the following guidelines: 

– Install the power supply before connecting the power cable to the power supply. 

– Unplug the power cable before removing the power supply. 

– If the system has multiple sources of power, disconnect power from the system by unplugging all

 

power cables    

from the power supplies. 

 

Move products with care; ensure that all casters and/or stabilizers are firmly connected to the system. Avoid 
sudden stops and uneven surfaces. 

 

 

General Precautions for Rack-Mountable Products 

Observe the following precautions for rack stability and safety. Also refer to the rack installation documentation 
accompanying the system and the rack for specific caution statements and procedures. 

Systems are considered to be components in a rack. Thus, "component" refers to any system as well as to various 
peripherals or supporting hardware. 

 

 

CAUTION:

 Installing systems in a rack without the front and side stabilizers installed could cause 

the rack to tip over, potentially resulting in bodily injury under certain circumstances. Therefore, 
always install the stabilizers before installing components in the rack.  

After installing system/components in a rack, never pull more than one component out of the 
rack on its slide assemblies at one time. The weight of more than one extended component 
could cause the rack to tip over and may result in serious injury. 

 

 

Before working on the rack, make sure that the stabilizers are secured to the rack, extended to the floor, and that 
the full weight of the rack rests on the floor. Install front and side stabilizers on a single rack or front stabilizers 
for joined multiple racks before working on the rack.

 

 

Always load the rack from the bottom up, and load the heaviest item in the rack first. 

 

Make sure that the rack is level and stable before extending a component from the rack. 

 

Use caution when pressing the component rail release latches and sliding a component into or out of a rack; the 
slide rails can pinch your fingers. 

 

After a component is inserted into the rack, carefully extend the rail into a locking position, and then slide the 
component into the rack. 

 

Do not overload the AC supply branch circuit that provides power to the rack. The total rack load should not 
exceed 80 percent of the branch circuit rating. 

 

Ensure that proper airflow is provided to components in the rack. 

 

Do not step on or stand on any component when servicing other components in a rack. 

 

 

 

 

NOTE:

 A qualified electrician must perform all connections to DC power and to safety grounds. 

All electrical wiring must comply with applicable local or national codes and practices. 

 

CAUTION:

 

Never defeat the ground conductor or operate the equipment in the absence of a 

suitably installed ground conductor. Contact the appropriate electrical inspection authority or an 
electrician if you are uncertain that suitable grounding is available. 

 

CAUTION:

 

The system chassis must be positively grounded to the rack cabinet frame. Do not 

attempt to connect power to the system until grounding cables are connected. Completed power 
and safety ground wiring must be inspected by a qualified electrical inspector. An energy hazard 
will exist if the safety ground cable is omitted or disconnected. 

Содержание DGS-1005D/B

Страница 1: ...DGS 1005D 5 Port 10 100 1000Mbps Switch Manual RECYCLABLE V4 60 ...

Страница 2: ...nd if not installed and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class B product In a domestic environment this product may cause radio inter...

Страница 3: ...GREEN TECHNOLOGY 2 SWITCHING TECHNOLOGY 3 SWITCH DESCRIPTION 3 Features 3 FRONT PANEL COMPONENTS 4 LED Indicators 5 REAR PANEL DESCRIPTION 6 INSTALLATION 7 Package Contents 7 BEFORE YOU CONNECT TO THE NETWORK 7 MOUNTING THE SWITCH ON A WALL 8 8POWER ON 8 Power Failure 8 CONNECTING THE SWITCH 9 SWITCH TO END NODE 9 SWITCH TO HUB OR SWITCH 9 CONNECTING TO NETWORK BACKBONE OR SERVER 10 TECHNICAL SPEC...

Страница 4: ...your Switch to an end node hub Switch or backbone server Appendix A Technical Specifications The technical specifications of the DGS 1005D Glossary Lists definitions for terms and acronyms used in this document Intended Readers The DGS 1005D Manual contains information for setup and management and of the DGS 1005D Switch This manual is intended for network managers familiar with network management...

Страница 5: ...power source required consult your service provider or local power company To help avoid damaging your system be sure the voltage selection switch if provided on the power supply is set to match the power available at your location 115 volts V 60 hertz Hz in most of North and South America and some Far Eastern countries such as South Korea and Taiwan 100 V 50 Hz in eastern Japan and 100 V 60 Hz in...

Страница 6: ... secured to the rack extended to the floor and that the full weight of the rack rests on the floor Install front and side stabilizers on a single rack or front stabilizers for joined multiple racks before working on the rack Always load the rack from the bottom up and load the heaviest item in the rack first Make sure that the rack is level and stable before extending a component from the rack Use...

Страница 7: ... the following steps to prevent damage from electrostatic discharge ESD 1 When unpacking a static sensitive component from its shipping carton do not remove the component from the antistatic packing material until you are ready to install the component in your system Just before unwrapping the antistatic packaging be sure to discharge static electricity from your body 2 When transporting a sensiti...

Страница 8: ... their busses get faster and more users use applications that generate more traffic Upgrading key components such as your backbone and servers to Gigabit Ethernet can greatly improve network response times as well as significantly speed up the traffic between your subnetworks Gigabit Ethernet enables fast optical fiber connections to support video conferencing complex imaging and similar data inte...

Страница 9: ...her priority queues are transmitted first D Link s Green Technology D Link s Green Technology implements special power saving features under speed at 1000Mbps that detect cable length and link status and adjust power usage accordingly Further D Link Green implement the newly ratified IEEE 802 3az Energy Efficient Ethernet standard for reducing energy consumption of network links during periods of ...

Страница 10: ...ridges which were characterized by higher latencies Routers have also been used to segment local area networks but the cost of a router and the setup and maintenance required make routers relatively impractical Today s Switches are an ideal solution to most kinds of local area network congestion problems Switch Description The DGS 1005D Switch is equipped with five ports providing dedicated 10 100...

Страница 11: ...net Switch Front Panel Components The top case of the Switch consists of LED indicators 5 10 100 1000 Mbps Ethernet ports Figure 1 1 Front Panel View of the Switch Comprehensive LED indicators display the status of the Switch and the network ...

Страница 12: ...t powered on the Cable Diagnostics function is initialized and run The Cable Diagnostics function will detect three common faults in an Ethernet cable connecting the Switch to a remote network device an open circuit a lack of continuity between the pins at each end of the Ethernet cable or a disconnected cable a short circuit two or more conductors short circuited and improper termination a termin...

Страница 13: ...AC power adapter Check the technical specification section for information about the AC power input voltage Figure 1 3 Rear panel view of the Switch 10 100 1000BASE T Ports Five 5 Gigabit Ethernet Auto Negotiating ports 10 100 1000Mbps Comprehensive LED indicators display the conditions of the Switch and status of the network ...

Страница 14: ...can support at least 3 kg 6 6 lbs of weight Do not place heavy objects on the Switch The power outlet should be within 1 82 meters 6 feet of the Switch Visually inspect the power cord and see that it is fully secured to the AC power port Make sure that there is adequate space for proper heat dissipation from and adequate ventilation around the Switch Leave at least 10 cm 4 inches of space at the f...

Страница 15: ... the mounting holes of the switch back on the screws you have completed the wall mount Figure 2 1 Mounting the Switch to a Wall C Mounting on a metal wall 1 Mount the magnetic base screws optional onto the mounting holes of the switch 2 Attach the switch to a metallic surface 3 The magnet kit is optional and is not included in the package contents Power On Plug one end of the AC to DC power adapte...

Страница 16: ...onnected to any of the ports of the Switch Figure 3 1 Switch connected to an end node Switch to Hub or Switch These connections can be accomplished in a number of ways using a standard Ethernet cable A 10BASE T hub or switch can be connected to the Switch via a twisted pair Category 3 4 5 or 5e UTP STP cable A 100BASE T hub or switch can be connected to the Switch via a twisted pair Category 5 or ...

Страница 17: ... a port on a hub or switch using either a straight or crossover cable any standard Ethernet cable is fine Connecting To Network Backbone or Server Any of the five Gigabit Ethernet ports are ideal for uplinking to a network backbone or network server Figure 3 3 Connection to a Server ...

Страница 18: ...Full duplex Gigabit Ethernet 2000Mbps Full duplex Topology Star Network Cables Ethernet 2 pair UTP Cat 3 4 5 Unshield Twisted Pair UTP Cable Fast Ethernet 2 pair UTP Cat 5 Unshield Twisted Pair UTP Cable Gigabit Ethernet 4 pair UTP Cat 5 Unshield Twisted Pair UTP Cable Number of Ports Five 10 100 1000BASE T Gigabit Ethernet ports Physical and Environmental DC Inputs AC DC 5V 1A Operating Temperatu...

Страница 19: ...thernet Switch Performance Transmission Method Store and forward RAM Buffer 128KBytes per device Filtering Address Table 2K address per device Packet Filtering Forwarding Rate Full wire speed MAC Address Learning Self learning auto aging ...

Страница 20: ...all destination devices on the network broadcast storm Multiple simultaneous broadcasts that typically absorb available network bandwidth and can cause network failure console port The port on the Switch accepting a terminal or modem connector It changes the parallel arrangement of data within computers to the serial form used on data transmission links This port is most often used for dedicated l...

Страница 21: ...otocol A protocol originally designed to be used in managing TCP IP internets SNMP is presently implemented on a wide range of computers and networking equipment and may be used to manage many aspects of network and end station operation Spanning Tree Protocol STP A bridge based system for providing fault tolerance on networks STP works by allowing you to implement parallel paths for network traff...

Отзывы: