2.48. VFS
These log messages refer to the VFS (VFS file handling events) category.
2.48.1. odm_execute_failded (ID: 05200001)
Default Severity
NOTICE
Log Message
Usage of file "<filename>" failed. File validated as "<description>".
Explanation
An uploaded file ([filename]) was validated as "[description]". An
error occured while using this file.
Gateway Action
None
Recommended Action
Check the origin of the file and make sure that the file is of the correct
format.
Revision
1
Parameters
filename
description
2.48.2. odm_execute_action_reboot (ID: 05200002)
Default Severity
NOTICE
Log Message
Uploaded file (<filename>) was validated as "<description>".
Rebooting system.
Explanation
An uploaded file was validated, and executed. The system will now
reboot.
Gateway Action
None
Recommended Action
None.
Revision
1
Parameters
filename
description
2.48.3. odm_execute_action_reconfigure (ID: 05200003)
Default Severity
NOTICE
Log Message
Uploaded file (<filename>) was validated as "<description>". Doing
system RECONFIGURE .
Explanation
An uploaded file was validated, and executed. The system will now
RECONFIGURE.
Gateway Action
None
Recommended Action
None.
Revision
1
2.48. VFS
Chapter 2. Log Message Reference
468
Содержание DFL-210 - NetDefend - Security Appliance
Страница 25: ...List of Tables 1 Abbreviations 28 25...
Страница 26: ...List of Examples 1 Log Message Parameters 27 2 Conditional Log Message Parameters 27 26...
Страница 36: ...1 3 Severity levels Chapter 1 Introduction 36...
Страница 156: ...Recommended Action None Revision 1 2 5 7 unsynced_databases ID 05000008 Chapter 2 Log Message Reference 156...
Страница 173: ...Context Parameters Packet Buffer 2 9 14 route_collision ID 00700015 Chapter 2 Log Message Reference 173...
Страница 195: ...2 12 6 route_removed ID 01100006 Chapter 2 Log Message Reference 195...
Страница 240: ...Revision 1 Parameters iface linkspeed duplex 2 20 3 ifacemon_status_bad ID 03900004 Chapter 2 Log Message Reference 240...
Страница 309: ...Context Parameters Rule Name Packet Buffer 2 24 3 ip_rsv_flag_set ID 01600003 Chapter 2 Log Message Reference 309...
Страница 409: ...2 40 19 scp_failed_not_admin ID 04704000 Chapter 2 Log Message Reference 409...
Страница 476: ...2 49 14 zd_block ID 03800014 Chapter 2 Log Message Reference 476...