Features and Benefits

 

 

 

(24) 10/100BASE-TX Fast Ethernet ports + (2) 1000BASE-T Gigabit Ethernet ports or (2) SFP(Mini GBIC)  for 2 

additional copper or fiber Gigabit connections 

 

Auto MDI/MDI-X support on each port 

 

Full-/half- duplex transfer mode for 10/100Mbps Fast Ethernet transmission 

 

Full-duplex transfer mode for Gigabit Ethernet transmission 

 

Wire-speed reception and transmission 

 

Store-and-Forward switching method 

 

Integrated address Look-Up Engine, supports 6K MAC addresses 

 

Supports 512K bytes RAM for data buffering 

 

Extensive front-panel diagnostic LEDs 

 

Broadcast storm protection 

 

IEEE 802.3x flow control for full-duplex 

 

Back pressure flow control for half-duplex 

 

Supports port-base VLAN  

 

Supports port-base QoS  

 

Supports Trunking  

 

Supports Port-mirroring 

 

Supports Port-setting for Speed/Disable, Flow control 

 

Easy configuration via Web Browser 

 

Easy setting via Web Management Utility 

 

Standard 19” Rack-mount size 

LEDs 

LED 

stands for 

L

ight-

E

mitting 

D

iode

.   

The front panel LEDs provides instant status feedback and simplifies monitoring and troubleshooting tasks.  

 

LED indicators of the Switch 

 

Power 

On 

  When the Power LED light is on, the Switch is receiving power. 

Off 

  When the Power LED light is off, the power cord is improperly 

connected. 

 

 

CPU (Management Indicator) 

Blinking 

:  When the CPU is working, the System LED is blinking. 

On/Off 

:  The CPU is not working. 

 

Ports 1-24 Status LEDs 

 

Link/Act 

On  

  When the LED light is on, the respective port is connected to 

the 10/100Mbps Ethernet network. 

Blinking  

  When the LED light is blinking, the port is transmitting or 

receiving data on the 10/100Mbps Ethernet network. 

Off  

No 

link. 

 

5

Содержание DES-1226G

Страница 1: ...D Link DES 1226G Web Smart 24 Port 10 100Mbps 2 Port Combo 10 100 1000Mbps Copper SFP Mini GBIC Gigabit Switch Manual First Edition Building Networks for People RECYCLABLE ...

Страница 2: ...Installation 7 4 Configuration 8 Configuring the Switch 12 Configuring Setup Setting 14 Port Settings 14 VLAN Settings Virtual Local Area Network 15 Trunk Setting 15 Mirror Setting 15 Device Status 16 System Setting 16 Trap Setting 16 Set Password 17 Backup Setting 17 Reset Setting 17 5 Technical Specifications 18 Warranty Information 23 International Offices26 ...

Страница 3: ...ctive way of increasing the total network capacity available to users on a LAN If an Ethernet network begins to display symptoms of congestion low throughput slow response times and high rates of collision installing a switch to a network can preserve much or all of the existing network s cabling and workstation interface card infrastructure while still greatly enhancing the throughput for users A...

Страница 4: ... faster switching instead Other VLAN utilities include Security Security is increased with the reduction of opportunity in eavesdropping on a broadcast network because data will be switched to only those confidential users within the VLAN Cost Reduction VLANs can be used to create multiple broadcast domains thus eliminating the need of expensive routers Port based or port group VLAN is the common ...

Страница 5: ...ase QoS Supports Trunking Supports Port mirroring Supports Port setting for Speed Disable Flow control Easy configuration via Web Browser Easy setting via Web Management Utility Standard 19 Rack mount size LEDs LED stands for Light Emitting Diode The front panel LEDs provides instant status feedback and simplifies monitoring and troubleshooting tasks LED indicators of the Switch Power On When the ...

Страница 6: ...is connected to a 10Mbps or Gigabit Ethernet network or there is no link Option Ports 25 26 SFP Mini GBIC Status LEDs Link Act On When the SFP Mini GBIC module is installed and connected to a network the Link ACT LED lights on Blinking When the LED is blinking the SFP Mini GBIC module is receiving data on a network Off No link 1000Mbps On When the 1000Mbps LED lights on the respective port is conn...

Страница 7: ...Reset button 3 Installation The site where you place the DES 1226G may greatly affect its performance When installing take the following into your consideration Install the DES 1226G in a fairly cool and dry place See the Technical Specifications for the acceptable temperature and humidity operating ranges Install the DES 1226G in a site free from strong electromagnetic field generators such as mo...

Страница 8: ...upply will adjust to the local power source automatically and may be turned on without having any or all LAN segment cables connected 4 Configuration Through the Web browser you can configure Switch settings such as VLAN Trunking QoS etc Using the Switch s Web Management Utility you can easily discover all the D Link Web Smart Switches in your network assign the IP Address change the password and ...

Страница 9: ...ored you can also receive a trap and show the status of the device System word definitions in the Monitor List S Shows the system symbol of the Web Smart device represents that the device system is not alive IP Address Shows the current IP address of the device MAC Address Shows the device MAC Address Protocol version Shows the version of the Utility protocol Product Name Shows the device product ...

Страница 10: ... In Configuration Setting you can set the IP Address Subnet Mask Gateway Set Trap to Trap IP Address System name and Location Select the device in the Discovery list or Monitor List and click the Configuration Setting button the Configuration Setting window will appear as seen in Figure 4 After entering the data that you want to change you must enter the password and press the Set button to proces...

Страница 11: ...agement Utility next time it will automatically load the default recorded setting Monitor Save As To record the setting of the Monitor List in appointed filename and file path Monitor Load To manually load the setting file of the Monitor List Exit To exit the Web Management Utility In the View TAB the options are view log and clear log function this function will help you to display trap settings ...

Страница 12: ...2 and 254 and the default subnet mask is 255 255 255 0 Open an Internet Explorer 5 0 or above Web browser Enter the IP address http 192 168 0 1 the factory default IP address setting in the address location Figure 7 Through the Web Management Utility you do not need to remember the IP Address select the device shown in the Monitor List of the Web Management Utility to settle the device on the Web ...

Страница 13: ...Figure 10 Setup menu 13 ...

Страница 14: ...et the Gigabit port when transferring the media type Fiber to Copper or Copper to Fiber 2 The priority of Gigabit Fiber port is higher than Copper To change the port setting click on the ID parameter to enter the selected port to configure its Speed Disable Flow control and QoS settings Figure 12 Speed Disable This setting has six modes 100M Full 100M Half 10M Full 10M Half Auto and Disable for sp...

Страница 15: ...de There are two trunking groups for selection you can select either or both groups for trunking Figure 15 Trunk Settings Be sure that the selected trunk setting port must connect to the device with a same VLAN group Mirror Setting Port Mirroring is a method of monitoring network traffic that forwards a copy of each incoming and or outgoing packet from one port of a network switch to another port ...

Страница 16: ...gin Timeout is to set the idle time out for security issues When there is no action when running the Web Smart Utility and it times out you must re login to Web Smart Utility before you set the Utility Fill up the IP Address Subnet Mask and Gateway for the device Figure 17 Trap Setting The Trap Setting enables the device to monitor the Trap through the Web Management Utility and set the Trap IP Ad...

Страница 17: ...t and the Switch will restore to the default setting Figure 19 Set Password Backup Setting The backup tools help you to backup the current settings of the Switch To backup your settings press the Backup button To restore a current settings file to the device you must specify the backup file and click on the Restore button to process the setting of the recorded file Figure 20 Backup Setting Note wh...

Страница 18: ...er module SFP Mini GBIC Fiber module Number of Ports 24 10 100BASE TX Auto MDIX STP ports 2 1000BASE T Auto MDIX STP ports 2 SFP Mini GBIC fiber slot Physical and Environmental AC inputs 100 to 240V AC 50 60 Hz internal universal power supply Power Consumption 16 watts max Temperature Operating 0 40 C Storage 10 70 C Humidity Operating 10 90 Storage 5 90 Dimensions 440 140 44 mm W H D 17 32 X 5 51...

Страница 19: ...anding anything stated herein to the contrary Submitting A Claim The customer shall return the product to the original purchase point based on its return policy In case the return policy period has expired and the product is within warranty the customer shall submit a claim to D Link as outlined below The customer must submit with the product as part of the claim a written description of the Hardw...

Страница 20: ... from D Link Corporation D Link Systems Inc as stipulated by the United States Copyright Act of 1976 Contents are subject to change without prior notice Copyright 2002 by D Link Corporation D Link Systems Inc All rights reserved CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measu...

Страница 21: ...E IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW STATUTORY OR OTHERWISE INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE D LINK NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE OR USE OF D LINK S PRODUCTS D LINK SHALL NOT BE LIABLE UNDER T...

Страница 22: ... product which substantially conforms to D Link s applicable product documentation Purchaser assumes responsibility for the selection of appropriate application and system platform software and associated reference materials D Link makes no warranty that its software products will work in combination with any hardware or any application or system platform software product provided by any third par...

Страница 23: ... Registration Register your product on line at http support dlink com register Product registration is entirely voluntary and failure to complete or return this form will not diminish your warranty rights ...

Страница 24: ...ng sold As Is without any warranty whatsoever including without limitation the Limited Warranty as described herein notwithstanding anything stated herein to the contrary Submitting A Claim The customer shall return the product to the original purchase point based on its return policy In case the return policy period has expired and the product is within warranty the customer shall submit a claim ...

Страница 25: ...opyright Statement No part of this publication or documentation accompanying this product may be reproduced in any form or by any means or used to make any derivative such as translation transformation or adaptation without permission from D Link Corporation D Link Systems Inc as stipulated by the United States Copyright Act of 1976 and any amendments thereto Contents are subject to change without...

Страница 26: ...fnock Avenue North Ryde NSW 2113 Australia TEL 61 2 8899 1800 FAX 61 2 8899 1868 URL www dlink com au India D Link House Kurla Bandra Complex Road Off CST Road Santacruz East Mumbai 400098 India TEL 91 022 26526696 56902210 FAX 91 022 26528914 URL www dlink co in Middle East Dubai P O Box 500376 Office No 103 Building 3 Dubai Internet City Dubai United Arab Emirates Tel 971 4 3916480 Fax 971 4 390...

Страница 27: ...trup Copenhagen Denmark TEL 45 43 969040 FAX 45 43 424347 URL www dlink dk URL www dlink com tr Egypt 19 El Shahed Helmy El Masri Al Maza Heliopolis Cairo Egypt TEL 202 414 4295 FAX 202 415 6704 URL www dlink me com Headquarters 2F No 233 2 Pao Chiao Rd Hsin Tien Taipei Taiwan TEL 886 2 2916 1600 FAX 886 2 2914 6299 URL www dlink com tw ...

Страница 28: ..._________________________ 4 What network operating system s does your organization use D Link LANsmart Novell NetWare NetWare Lite SCO Unix Xenix PC NFS 3Com 3 Open Banyan Vines DECnet Pathwork Windows NT Windows 2000 Windows XP Others_____________________________________________________________________________ 5 What network management program does your organization use D View HP OpenView Windows...

Страница 29: ...29 ...

Отзывы: