background image

                                                           

FCC ID: KA2CHZ112A1

                                                         
IC ID: 4216A-CHZ112A1

Disposal

 

This marking indicates that this product should not be 
disposed with other household wastes throughout the EU. 
To prevent possible harm to the environment or human 
health from uncontrolled waste disposal, recycle it 
responsibly to promote the sustainable reuse of material 
resources. To return your used device, please use the 
return and collection systems or contact the retailer where 
the product was purchased. They can take this product for 
environmental safe recycling.

Company of License Holder

Philio Technology Corporation

Address of License Holder

8F., No.653-2, Zhongzheng Rd., Xinzhuang 

Dist., New Taipei City 24257, Taiwan(R.O.C)

FCC Interference Statement 

This equipment has been tested and found to comply with the limits for

a Class B digital device, pursuant to Part 15 of the FCC Rules. These

limits are designed to provide reasonable protection against harmful

interference   in   a   residential   installation.   This   equipment   generates,

uses and can radiate radio frequency energy and, if not installed and

used   in   accordance   with   the   instructions,     may   cause   harmful

interference   to   radio   communications.         However,     there   is   no

guarantee that interference will not occur in a particular installation.  If

this equipment does cause harmful interference to radio or television

reception,  which can be determined by turning the equipment off and

on,  the user is encouraged to try to correct the interference by one of

the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from

that to which the receiver is connected.

Consult   the   dealer   or   an   experienced   radio/TV   technician   for

help.

This device complies with Part 15 of the FCC Rules. Operation is subject

to the following two conditions: 

(1) This device may not cause harmful interference, and

(2)   This   device   must   accept   any   interference   received,   including

interference that may cause undesired operation. 

 

FCC Caution: Any changes or modifications not expressly approved by

the party responsible for compliance could void the user's authority to

operate this equipment. 

 

This transmitter must not be  co-located  or  operating in conjunction

with any other antenna or transmitter.

Warning

Do not dispose of electrical appliances as unsorted municipal waste,

use   separate   collection   facilities.   Contact   your   local   government   for

information   regarding   the   collection   systems   available.   If   electrical

8

Содержание DCH-112

Страница 1: ...s The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Add to Remove from Z WaveTM Network There are two tamper keys in the device one is in the back side another is in the front side Both of them can add remove reset or association...

Страница 2: ...ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM network Notice 2 When the device into NWI mode the sensor functionality will useless The NWI mode will timeout after 30 seconds You can press the tamper key 3 times to abort the NWI mode Z WaveTM Notification After the device adding to the network it will wake up once per day in ...

Страница 3: ...ery 6 hours report once in default It could be changed by setting the configuration NO 10 Low battery report When the battery level is too low every 30 minutes will report once Door window state report Every 6 hours report once in default It could be changed by setting the configuration NO 11 Illumination level report Every 6 hours report once in default It could be changed by setting the configur...

Страница 4: ...also will light ON one second When the event triggered the device will report the messages to the nodes in the group 1 The messages also include the battery level the temperature and the illumination level The user can switch the report by setting the configuration NO 5 bit4 illumination and bit5 temperature and the configuration NO 7 bit6 battery When the event triggered if the environment lumina...

Страница 5: ...he device trig please associate with the device into the second group 3 In the accessory pack There are two type of double coated tape one is thicker hereinafter referred to as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let ...

Страница 6: ...report after event triggered 1 Disable 0 Enable 0 Bit5 Disable the temperature report after event triggered 1 Disable 0 Enable NO Name Def Vali d A B C Description 0 Bit6 Reserve 0 Bit7 Disable the back key release into test mode 1 Disable 0 Enable 7 Customer Function 4 All Customer function switch using bit control Caution The value is unsigned byte the range is from 0x00 0xFF 0 Bit0 Reserve 0 Bi...

Страница 7: ...Setting to 0 means turn off all auto report function Caution2 The value is unsigned byte the range is from 0x00 0xFF Z Wave Supported Command Class COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION_V4 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_SE...

Страница 8: ...wever there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between t...

Страница 9: ...s substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new once the retailer is legally obligated to take back your old appliance for disposal at least for free of charge 9 ...

Отзывы: