background image

2

D-fend™ SA300 User Manual

Compliance

Please note there is a shock hazard and there are no serviceable parts inside this device.  D-fend is FCC Class A certified, 
CE certified, and RoHs/WEEE compliant.  Please read the manual before using this product.

Warranty Information

The Eminence/D-fend Technology warranty remains in effect for one year from the date of the first consumer purchase (in 
the USA) with the original bill of sale.  Without an original bill of sale, the manufacturing date will establish the beginning of 
the warranty period.
 
Your warranty covers all defects in material and workmanship except: damage caused by accident, misuse, abuse, product 
modification or neglect, damage incurred during shipment, claims based upon any misrepresentation by the seller, or any 
Eminence/D-fend Technology product on which the date code/serial number has been defaced, modified or removed.
 
Eminence will pay all labor and material expenses for all repairs covered by this warranty.  Please be sure to save the 
original shipping cartons. A charge will be made if replacement cartons are requested.  You are responsible for transporting 
your product for repair or arranging for its transportation and for payment of any initial shipping charges.  We will pay the 
return shipping charges if repairs are covered by the warranty.

Eminence’s liability is limited to the repair or replacement, at our option, of any defective product and shall not include 
incidental or consequential damage of any kind.

This warranty gives you specific legal rights.  You may also have other rights which vary from state to state.
 
If your Eminence/D-fend Technology product ever needs service, contact us at 

Eminence Speaker LLC
P. O. Box 360 
838 Mulberry Pike
Eminence, KY  40019
502.845.5622 phone
502.845.5653 fax, 
[email protected] (for warranty purposes only)
[email protected] (for general inquiries)

Or you may contact the distributor or dealer where you purchased the product.  Please do not ship your product to the 
Eminence factory without prior authorization.
 
Use the email address, [email protected] for warranty issues only.  For all non-warranty issues, please contact 
Eminence at [email protected].

Содержание SA300

Страница 1: ...g Recommendation 17 Advanced Programming 18 Dual sub 20 Full system 21 Tweeter protection 25 Distributed systems 26 Troubleshooting 27 Technical Support 28 2013 Eminence Speaker LLC All rights reserve...

Страница 2: ...ure to save the original shipping cartons A charge will be made if replacement cartons are requested You are responsible for transporting your product for repair or arranging for its transportation an...

Страница 3: ...for users such as yourself to experience peace of mind concerning your loudspeaker investment With the D fend digital attenuator under complete microprocessor control you have at your fingertips a wo...

Страница 4: ...lluminates in the event that the user defined high frequency peak or RMS voltage thresholds have been matched or exceeded A red light here signifies RMS voltages in the high frequency band have trigge...

Страница 5: ...hold settings are below the minimum audio signal power required to activate the D fend protection device see Specifications section below or in the event that it is undesired to use the audio signal a...

Страница 6: ...ack and Release Times Attack time Determines how fast the D fend processing engages after the signal has exceeded the threshold Setting the attack time to a short value will result in a fast response...

Страница 7: ...elow the F3 is 40Hz 20 Hz 50 30 40 100 200 dBSPL 85 90 95 100 3 dB HF High Frequency the spectral content reproduced by tweeters LF Low Frequency the spectral content reproduced by woofers and subwoof...

Страница 8: ...are sent to the D fend SA300 Offline Your D fend unit is not properly connected via USB to your computer System Impedance Complex resistance expressed in ohms it is the electrical impedance to current...

Страница 9: ...fend To connect the D fend SA300 to your computer simply connect the provided USB cable to an available USB port on your computer and connect the mini USB end of the cable to the front of the D fend...

Страница 10: ...0 unit but the total load seen by the SA300 and power run through the SA300 must fall within the ratings guidelines given in the Maximum Minimum Power Specifications on page 5 Full System In this sect...

Страница 11: ...0 watt load to the output of the SA300 assigned to protect them The amplifier used to power them has one channel that is capable of 1000 watts into a 2 ohm load so it will be connected to the input of...

Страница 12: ...e of those situations 25 70 100 Volt Distributed Systems Attention The SA300 can not be used AFTER an audio transformer The SA300 can be used in 25 and 70 volt distributed systems that use either a tr...

Страница 13: ...er to get the high voltage low current required If you do have to use a step up transformer the SA300 will be connected between the amplifier and step up transformer Please see fig 2 5 to see the corr...

Страница 14: ...ection of the manual for explanation of the terms used within the Wizard Figure 3 Figure 3 1 Step 2 You are given the option of selecting Subwoofer or Multi way in the Enclosure Type section If you ar...

Страница 15: ...duced rating and work your way up to a level you feel comfortable with and does not exceed the manufacturer s rating Listen to the cabinet and make adjustments as needed Figure 3 3 shows an example of...

Страница 16: ...he Computer to D fend button figure 3 6 Figure 3 6 Once the Computer to D fend button is clicked you will receive another warning screen asking you if you wish to continue If not click Cancel If so cl...

Страница 17: ...llow you to run it very hard without fear of blowing something up if it is set correctly The SA300 needs to be configured so the system can be run at its limits and the SA300 does not have any sonic i...

Страница 18: ...what fast thereby allowing quick transient protection for your high frequency driver All Pass path Configuration Next you will want to configure the All Pass path AP The AP path displayed within the A...

Страница 19: ...und it quite beneficial to have the computer connected to the SA300 during system set up so that we can monitor the actions of the SA300 during musical testing the lights on the SA300 may not be visib...

Страница 20: ...ter of 1600 or 400 watts to begin with If working in volts this would be 40 v Again the software may not accept one of your entries exactly as entered defaulting to the closest selection found in the...

Страница 21: ...boxes and floor wedges There will be three speaker level signals so we will need to use three SA300 units to completely protect the system Let s break the full system down into its three parts and see...

Страница 22: ...watts We checked with the manufacturer and find that the F3 is 80 Hz and the crossover from the woofer to the compression driver is at 1650 Hz We recommend you begin with setting the SA300 for of the...

Страница 23: ...needed and send the revised settings to the SA300 to either make the top box louder sound more natural or be protected even more Again it will be up to you to decide what level of protection you want...

Страница 24: ...SA300 does The SA300 is not a feedback eliminator but it should be able to protect your wedges from the steady state and sometimes escalating howl that can burn out unprotected tweeters Make adjustmen...

Страница 25: ...ten to some music at your normal playback level and keep an eye on the SA300 s indicators either on the unit or in the Advanced Programming GUI if the computer is still connected to the SA300 If you t...

Страница 26: ...transformer in turn drives a network of loudspeakers incorporating step down transformers The SA300 should be connected between the amplifier output and the primary or input of the step up transformer...

Страница 27: ...urther information on the voltage and current limitations of the D fend SA300 2 You may have reached the thermal limits of the D fend SA300 D fend incorporates built in thermal protection circuitry wh...

Страница 28: ...ge at http www d fend net support faqs 2 Send an e mail with D fend technical support in the subject line to dfend eminence com and include a description of the issue you are experiencing A representa...

Отзывы: