background image

       

 

  

   P1 PRO 

 DOSING PUMP 

 
 
 
 USER MANUAL 

 

 

 

 

Содержание P1 PRO

Страница 1: ...P1 PRO DOSING PUMP USER MANUAL...

Страница 2: ...he app 4 Register your cloud account 4 Connect your dosing pump to the cloud 5 Programming the dosing pump 6 Setting the dosing plans 6 Advanced plan adjustments 9 Manual addition 12 Calibration 13 Ad...

Страница 3: ...Pharmed BPT pump tube offers long life heat resistance acid alkali resistance and ozone UV resistance Up to 24 dosing plans per day 1 99 day cycle or specified weekly dosing Pump head can be calibrate...

Страница 4: ...t and the outlet height siphoning may occur In order to avoid siphoning the dosing pump should be placed in a position to ensure that the height difference between the inlet and the outlet is within 0...

Страница 5: ...the Google Play store search for Kamoer Remote find the app download of the corresponding icon Kamoer Remote app supports Android 4 4 and above and supports iOS 9 1 and above Register your cloud acco...

Страница 6: ...o connect the dosing pump through a wireless router to the cloud Open the app click the button in the upper right corner of the device to add the device Under the D D H2Ocean heading select the P1 PRO...

Страница 7: ...e dosing plan Tap on Cycle time and choose if you want to set up the schedule dosing frequency By Days or Weekly By Days will set the pump to dose every X days e g every 3 days This can be set from ev...

Страница 8: ...much it will add on each dose From here set the Anti chemical interference can also be set If you are using multiple P1 PRO dosing pumps this can be used to prevent them dosing at the same time The t...

Страница 9: ...e pump has been set to dose every three days a total of 10ml split into 24 doses between 00 00 and 23 59 The dosing container has 999 6ml of solution left in it and should therefore last approximately...

Страница 10: ...and dose amount as required select Save to confirm the change It is only possible to set a time within the period set for the plan group Plan points will always be displayed in time order If two point...

Страница 11: ...n group period it is best to delete the existing group plan by swiping the plan to the left and set up a new one as described in this manual Plan points can be added to an existing group by selecting...

Страница 12: ...roup will be overwritten Multiple plan groups can be added to the same pump This will allow different plans to be set in a single day To add a plan group tap on the symbol enter the group name and tim...

Страница 13: ...on at the bottom middle of the screen This will open the manual settings page Tap on the number and enter the amount of liquid you would like to add The pump should now show the amount set for the man...

Страница 14: ...ation When the dosing pump is initially set up the pump head has been replaced or if the unit has been in service for a period of time it is worth calibrating pump heads to ensure accuracy To calibrat...

Страница 15: ...e pump will run for the time selected in the previous step Once the pump has stopped remove the outlet hose from the measuring cylinder and stand the measuring cylinder on a flat surface Use the scale...

Страница 16: ...ollow the instructions on screen Do not close the app or power down the unit during this process Time setting The unit should automatically sync to the correct time when setup and keep the correct tim...

Страница 17: ...nit is reset This will not remove the unit from the app or cloud Do not power off the unit during this process Remove Device To remove the device from the app tap on Remove Device and select remove Th...

Страница 18: ...purchase D D The Aquarium Solution Ltd undertakes to repair or at our decision replace the defective part free of charge Our policy is one of continual technical improvement and we reserve the right...

Отзывы: