12
Remember the PRC on the
D-100
amplifier:
CONFIGURATIONS (cont’d)
Manual del Usuario
/ SF series /
User’s Manual
PRC
PRC
PRC
PRC
D-100
PRC switches: Each channel of the amplifier may be
power limited independently using these pairs of switches
in three stages, offering 2, 4 and 6dB of Power Reduction
Control. The settings for these switches are on the rear
panel for quick reference.
Power Current and Thermal Emissions:
D-100
No Sig'l = Quiescent, Light = Crest Factor of 7.8(18dB),
Average = Crest Factor of 4.8(14dB), Heavy = Crest Factor of 2.8 (9dB)
For details of measurement methods please refer to the Technical Support area of our website.
PRC Settings and Maximum Output:
D-100
Mains
(V)
Load
(R)
Cur rent Dr aw
(A)
Ther mal Emissions
(W)
No Sig’l
Light
Average
Heavy
No Sig’l
Light
Average
Heavy
240
8
2.1
3.0
4.5
8.3
504
528
566
660
240
4
2.1
3.9
7.0
14.4
504
551
628
816
240
2
2.1
4.5
8.6
19.1
504
564
668
936
120
8
4.2
6.0
9.0
16.6
504
528
566
660
120
4
4.2
7.8
14.0
28.8
504
551
628
816
120
2
4.2
9.0
17.2
38.2
504
564
668
936