ANNEX II : DASnet cables
22
Manual del Usuario
/ SF series /
User’s Manual
With each system,
cabling and patch panels are provided
. It is very important to use the
system with the intended cables to prevent electromagnetic interferences between the
analog audio signal, the DASnet data and the power. Be sure to check the specifications
provided by the cable manufacturer. It is also especially important when installing
connectors yourself, to note that when termination is not accurate, a cable will be unable to
achieve its maximum performance and could have interferences.
There are 4 different types of cables.
- The main feeds which include power and a STP, CAT7 cable. These cables are
named
eCP_xx
(xx refers to cable length).
- The links between cabinets (aero40A/Convert15A/LX-218CAnet), which are STP
CAT7 cables. Cable code
eC_09
- Power Links between cabinets.Cable code
Plink1_09
-
Links for RoadNet series. Power+STP CAT7. eCPk_1/eCPk_5
The main feed cable eCP_xx has the following structure:
AL Shield
2
2
ecP_xx: Power cable 3x2.5mm + CAT7 4x (2 x 0.14mm )
Jacket
Jacket
STP CAT 7 cable with Aluminium Shield for
each individual pair and a main aluminium
Shield.
The main Shield has to be soldered to the
etherCon housing.
The eC_09 cable is a CAT5e cable with
global Aluminium Shield.
Important
The pin out of the EtherCon to XLR is the following on the eCP cables:
1
Orange-White
Audio+ 2
2
Orange
Audio- 3
3
Green-White
Audio Earth 1
4
Blue
5
Blue-White
6
Green
Data Earth 1
7
Brown-White
Data- (A) 3
8
Brown
Data+ (B) 2
etherCon
XLR