115V DASNET-RACK: maximum number of cabinets - 9 AERO-40A + 6 LX-218CA-NET
With these values, in one phase we will have:
RMS current: 3 x
AERO-40A
and 2 x
LX-218CA-NET
--> 18A + 12,4A RMS = 30,4A RMS,
phase max RMS current is 30A.
Peak current: 3 x
AERO-40A
and 2 x
LX-218CA-NET
--> 48A + 80A peak = 128A Peak, each
circuit breaker can stand 10In < I < 20In, that is to say between 200A< I < 400A.