D.A.S. AERO-20A Скачать руководство пользователя страница 17

ANNEX II : DASnet cables

17

With each system, 

cabling and patch panels are provided

. It is very important to use the system 

with the intended cables to prevent electromagnetic interferences between the analog audio signal, 
the  DASnet  data  and  the  power.  Be  sure  to  check  the  specifications  provided  by  the  cable 
manufacturer. It is also especially important when installing connectors yourself, to note that when 
termination is not accurate, a cable will be unable to achieve its maximum performance and could 
have interferences.

There are 4 different types of cables. 

 

- The main feeds which include power and a STP, CAT7 cable. These cables are named 

eCP_xx

 (xx refers to cable length).

 

- The links between cabinets (aero40A/Convert15A/LX-218CAnet), which are STP CAT7 

cables. Cable code 

eC_09

 

- Power Links between cabinets.Cable code 

Plink1_09

 

Links for RoadNet series. Power+STP CAT7. eCPk_1/eCPk_5

The main feed cable eCP_xx has the following structure:

AL Shield

2

2

ecP_xx:   Power cable 3x2,5mm  + CAT7 4x (2 x 0,14mm  )

Jacket

Jacket

STP CAT 7 cable with Aluminium Shield for 
each individual pair and a main aluminium 
Shield.
The main Shield has to be soldered to the 
etherCon housing.

The eC_09 cable is a CAT5e cable with 
global Aluminium Shield.

Important

The pin out of the EtherCon to XLR is the following on the eCP cables:

Orange-White  

 

Audio+ 2

Orange 

 

 

Audio- 3

Green-White   

 

Audio Earth 1

Blue      

Blue-White        

Green   

 

 

Data Earth 1

Brown-White   

 

Data- (A) 3

Brown   

 

 

Data+ (B) 2

etherCon

XLR

Manual del Usuario

 / aero series / 

User’s Manual

Содержание AERO-20A

Страница 1: ...o lea la secci n Precauciones de seguridad de este manual Conserveestemanualparafuturasconsultas Before operating the device please read the Safety precautions section of this manual Retainthismanualf...

Страница 2: ...S RIGGING SYSTEM ANNEX I ANNEX II Description ON OFF Overload Indicators Overheating Equalisation Low mains voltage Current consumption CONFIGURATIONS CHANGE OF CONFIGURATION Troubleshooting Line cone...

Страница 3: ...should be flown only from the rigging points and by qualified personnel Do not suspend the box from the handles and respect the maximium load values given in the manual Limpie con un pa o seco No use...

Страница 4: ...araci n en garant a es imprescindible que el producto no haya sido previamente manipulado e incluir una fotocopia de la factura de compra All our products are warrantied against any manufacturing defe...

Страница 5: ...ic compatibility of multimedia equipment Emission requirements l EN 55103 2 2009 Electromagnetic compatibility Product family standard for audio video audio visual and entertainment lighting control a...

Страница 6: ...AERO 20A incorporates the latest in digital signal processors Brick wall FIR filters have been used to provide perfect alignment between ways achieving exceptionally uniform coverage inclusive at the...

Страница 7: ...1pol 1 x RCD 40A 30mA 4pol 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 2 3 1 PUSH 2 3 1 PUSH 2 3 1 PUSH eCP_3 eCP_20 IN OUT1 OUT2 OUT3 eCP_20 eCP_20 IN O...

Страница 8: ...I o FI40 30mA 4pol FI Schalter 6 x MCB 16A C 1pol 1 x RCD 40A 30mA 4pol 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 1 3 2 2 3 1 PUSH 2 3 1 PUSH 2 3 1 PUSH L1 L...

Страница 9: ...ies 800 W Class D 400 W Class D Balanced Differencial Line Line 20 kOhms Line 6 2 V 18dBu 60 Hz 20 kHz 90 Nominal 120 Nominal Splay Dependent 136 dB 135 dB LF 1 x 12AN4 GM 12AN4 HF 1 x M 75N GM M75N T...

Страница 10: ...tware 9 THROW SELECTOR A button that allows selecting the throw preset in the rear panel 10 THROW LED The LED that shines indicates the selected preset 11 NUMBER OF UNITS SELECTOR A button that switch...

Страница 11: ...tection mode you should then find out why and if necessary contact an authorised dealer for technical assistance Equalisation The unit does not need extreme settings of equalisation to produce quality...

Страница 12: ...connected to the same phase 1 Bad or loose AC connection to the UNIT or the mains outlet 2 Faulty AC cable 3 Internal fuse blown SOLUTION 1 Check that the mixer or sound source is sending signal to t...

Страница 13: ...ult factory settings Number of units Throw gain delay without using DASnet the system has to be switched ON while pressing the Throw button By doing this the cabinet will be set up with the Number of...

Страница 14: ...in slings and 7 1 for polyester slings Thus an element with a breaking load limit of 1000 kg may be statically loaded with 200 kg 5 1 safety factor and dynamically loaded with 142 kg 7 1 safety factor...

Страница 15: ...eCPk_5 number refers to cable length meters EtherCon cable Powercable eCP Other accessories DASnet rack 26 115V 2 patch panel power distro 30Amp American version DASnet rack 26 230V 2 patch panel pow...

Страница 16: ...s in the same way At the device s input the two signals get summed with opposite sign so that noise is cancelled out while the programme signal doubles in level Most professional audio devices use bal...

Страница 17: ...rs to cable length The links between cabinets aero40A Convert15A LX 218CAnet which are STP CAT7 cables Cable code eC_09 Power Links between cabinets Cable code Plink1_09 Links for RoadNet series Power...

Страница 18: ...8 DAS 4 USA DAS Audio Asia PTE LTD 3 Temasek Avenue Centennial Tower 34 36 Singapore 039190 Tel 65 6549 7760 DAS Audio Group S L C Islas Baleares 24 46988 Fuente del Jarro Valencia SPAIN Tel 34 96 134...

Отзывы: