It is very  im portant to ensure that these instructions are fully  read and understood before any  installation of this equipment is 
done. This gate operator uses high voltage electricity . Im proper installation or use of this equipm ent m ay  lead to electrical 
shock. It is the responsibility  of the installer to ensure that the electrical wiring is done to specification as explained in these 
instructions. It is im portant to check that the gate is in a good working condition before the operator is installed.   
Ensure that all electrical power is switched off before any  electrical connections are m ade. 
It is recomm ended that an experienced installer is used to install this operator, however it can be installed by  the hom e 
owner. The operator has been designed so that it can be installed without the need to run high voltage (220 V/AC) to the 
operator. However in the case of any  high voltage wiring (220 volts AC )  being used, this  m ust done by  a registered electri-
cian. This is a legal requirement. 
Do not open , tam per or m odify  any  of the electrical com ponents of this equipment in any  way . 
Do not attem pt to repair the equipment, this should only  be done by  a qualified D.A.C.E. technician. 
It is recomm ended that DuraTronic infra-red safety  beam s are used to reduce the chance of the gate closing on a vehicle or 
pedestrian.  
 
ENTRAPMENT AREAS: It m ust be noted that an automatic gate is a heavy  piece of equipment and inj ury  or even death 
m ay  occur due to incorrect installation or operation of the equipment.  
There are a num ber of areas that may  cause entrapm ent which could lead to inj ury .  
Do not allow children to operate or play  with the gate in any  way . 
Do not operate the gate unless within direct sight. 
 
 

Shaded areas show the possible entrapm ent areas of an autom ated gate. 

SAFETY FIRST 

Do not operate the gate unless within direct sight of the gate. 

25  

 

L.E.D. INDICATIONS 

There are several light em itting diodes (L.E.Ds) on the m ain P.C.Board. These L.E.Ds indicate several conditions. These 
indications are as follows:- 
 
STAUS LED.   ON = gate open or gate is in m otion. 
                          OFF = m ains power off.  
                          FLASHING ONCE EVERY TWO SECONDS = gate closed and mains power on. 
                          
                          
OPEN LED.       ON = gate open  
 
CLOSED LED.  ON = gate closed. 
 
12v LED.           ON =  normal. 
                           OFF= 12 volt output fault. (Possible 3 am p fuse open) rem ove power to re-set. 
 
INF LED.           ON = norm al. 
                           OFF = infra red beam s faulty  or obstruction in front of beam s. 
This LED should be on at all tim es unless there is an obstruction in front of the beam s. 
 
TRIG LED.        ON = permanent trigger / trigger fault 
                           OFF = norm al. 
This LED should be off at all tim es and will flash when the m otor is receiving a trigger. 
 
PED LED.         ON =  perm anent trigger / trigger fault 
                          OFF = norm al.  
This LED should be off at all tim es and will flash when the m otor is receiving a  pedestrian trigger. 
 
CHARGE LED (Com pact 500 only ) (green LED on the outside of the m otor). ON = normal. 
                                                                                             OFF = battery  is not charging . 
 

L.C.D  SCREEN INDICATIONS. (Compact 300 only) 

PROGRAM MODE PRESS TEST BUTTON—this indicates that the m otor is in the program  m ode and the test button 
m ust be pressed to start the programm ing sequence. 
GATE CLOSING—this indicates that the gate is closing. 
GATE OPENING—this indicates that the gate is opening. 
GATE CLOSED—this indicates that the gate is closed. 
GATE OPEN—this indicates that the gate is open. 
AUTO-CLOSE ACTIVE—this indicates that the m otor will close after the selected auto-close tim e. 
PARTY MODE –this indicates that the auto –close function has been over-ridden. 
MARKER OK—this indicates that the marker has sensed the m agnet on the gate. 
LOW BATT—this indicates that the battery  is flat. 
MAINS FAIL—this indicates that the mains power is off. 
BEAMS BLOCKED—this indicates that the infra –red safety  beam s are blocked or faulty . 
SERVICE DUE –this indicates that the gate has done over 7000 operations and requires a service. 
OBSTRUCTION—this indicates that the gate has sensed and obstruction in its path.  
 
  

Содержание Compact 300

Страница 1: ...28 COMPACT 300 500 OWNERS MANUAL Please read carefully before installing the motor...

Страница 2: ...ndications 25 External L E D 26 Warranty 26 Specifications 27 Installers details 27 INDEX 27 COMPACT 500 COMPACT 300 Intended use Domestic Domestic Max gate mass 500 kg 300 kg Max gate length 8m 8m Ma...

Страница 3: ...e riskof the gate striking an object Note The installation of beams does not guarantee against the gate striking an object in its path while moving Never allow children to play on or near any automati...

Страница 4: ...ht of the gate 25 L E D INDICATIONS There are several light emitting diodes L E Ds on the main P C Board These L E Ds indicate several conditions These indications are as follows STAUS LED ON gate ope...

Страница 5: ...e the gate Transformer Reduces 220volts to 16 volts Test button trigger Button to operate the gate from the P C Board Used during programming ABOUT OVER CURRENT When the gate is movingand it strikes a...

Страница 6: ...pictures The Compact 500 is shown with the battery removed The foundation plate base gearbox electric motor battery P C Board and the lid are all shared parts by both motors The Compact 500 and the C...

Страница 7: ...set is placed inside the house office and the gate sta tion is placed at the point of entry this is normally at the gate The gate station is normally mounted by means of a gooseneck It is important to...

Страница 8: ...may lead to the gate jamming This may lead to motor over current or blowingfuses The rail should be above ground level SITE EVALUATION Keepall trees branches bushes and other growthclear of the gate...

Страница 9: ...eafter this reduces the chance of the gate closing on an object Although the Compactmotor is designed to be used in a domestic application only this function is available To set multi user mode place...

Страница 10: ...he remotes have beenerased from the receiver ERASING A SINGLE REMOTE FROM THE RECEIVER To erase one single remote from the receiver the remotes need to be numbered in order of programming This means t...

Страница 11: ...iece of electronic equipment All electronic equipment should be handled with care Never connect or remove wires ona P C Board while there is power on the boardas this may lead to damage Never touch th...

Страница 12: ...LUE WIRE BLACK WIRE BLUE WIRE BLACK WIRE Closing direction Closing direction The following diagrams show the correct wiring of the electric motor to the main P C Board The motor wiresare found protrud...

Страница 13: ...t be adjusted to allow a 2mm gap between the pinion gear and the rack The best way of doing this is by dropping the motor 2mm on the bolts Push the gate open and closed by hand toensure that the racki...

Страница 14: ...the foundation plate Use 8 mm coach screws to mount the foundation plate to the concrete Dig a hole about 300mm square 1 Top view Foundation plate Gate Side view Foundation plate 35mm ANCHORING THE MO...

Отзывы: