19
EN / CZone® Control 1
LABELS & FUSES
1. Label the Circuits
1. Using a suitable label maker, print the output names (1-16) matching the load list and physical plug
connections.
2. Label the Inputs
1. Using a marker pen, write the analogue and digital input names matching the input list and physical plug
connections.
2. Write the Control 1 module number and location (i.e. Control 1 01
– Engine Room). This should match the
module name in the configuration.
3. Mark the dipswitch setting of the Control 1. This is usually assigned automatically when writing the
configuration and needs to be unique for each module on the CZone system.
INSERT FUSES
Figure 11. Fuses In Normal Operation
IMPORTANT: The Control 1 is not software fused like the COI module, so it is imperative each ATC fuse is
rated to protect the cable connected to the output. Failure in doing so may cause a fire hazard.
1. Insert appropriately rated ATC fuses into the NORMAL operation (bottom) position of all fuse holders.
1
2