5  Installation 

  GUIDELINES 

  Ensure the modules are installed vertically with the cables exiting downwards, this ensures IPX5 rating is 

retained. 

  All seals and cable glands must be fitted including blanking plugs inserted in any unused positions.  

  Ensure all labels are fitted and correct 

 

 

 

 

 

 

 

 

 

 

 

 

  CONNECTIONS 

  Connect DC Neg to SI input 8, used as reference to ground.  

  Connect each input to SI, inputs 1-6. Input 7 is not connected.  

  Connect an NMEA2000 drop cable from the SI to the NMEA2000 backbone. 

  Ensure NMEA2000 network is properly terminated and connected to 12V power source. 

 

 

Figure 3. Connections 

No connection

DC Negative

Signal input 1

Signal input 2

Signal input 3

Signal input 4

Signal input 5

Signal input 6

Signal inputs:

10-180 Ohm Sender

240-33 Ohm Sender

0-5v Sender

Negative (for switching purposes)

Positive (0-32v, for switching purposes )

NMEA2000 Micro C 

Mount Vertically 

Cable Exit 

Figure 2. Mounting 

Содержание 80-911-0013-00

Страница 1: ...Signal Interface SI User Installation Manual V2 0...

Страница 2: ...rpose 4 Organizational Measures 4 Maintenance and Repair 4 General Safety and Installation Precautions 4 4 OVERVIEW 5 Description 5 Features 5 Component Overview 5 5 INSTALLATION 6 Guidelines 6 Connec...

Страница 3: ...ines and measures Please keep this manual in a secure place GUARANTEE SPECIFICATIONS BEP Marine guarantees that this unit has been built according to the legally applicable standards and specification...

Страница 4: ...Signal Interface in locations where there is danger of gas or dust explosion or potentially flammable products 3 Use of the Signal Interface other than mentioned in point 2 is not considered to be co...

Страница 5: ...t switch Accepts inputs from industry standard tank senders 0 5V 10 180 Ohm 240 33 Ohm Accepts inputs from general voltaic or resistive signals can be used for controlling outputs or to display a phys...

Страница 6: ...ut 8 used as reference to ground Connect each input to SI inputs 1 6 Input 7 is not connected Connect an NMEA2000 drop cable from the SI to the NMEA2000 backbone Ensure NMEA2000 network is properly te...

Страница 7: ...00 Network LED lights up It may also be flashing if other devices are present and transmitting data 4 Check that the Power indicator LED is green 5 Check the circuit s status LEDs for each individual...

Страница 8: ...d Flash Configuration Conflict 3x Red Flash Dip Switch Conflict 4x Red Flash Memory Comms Failure 5x Red Flash No Modules Detected 6x Red Flash Fault On Output 7x Red Flash Output Not Detected 8x Red...

Страница 9: ...hese labels are to be fitted to the cover and to the module this prevents covers being swapped To record the module type and dipswitch settings use a permanent marker and strike through the applicable...

Страница 10: ...ATTERY SEND NEG TANK SENDER 0 5 VOLT CIRCUIT BREAKER No connection DC Negative Signal input 1 Signal input 2 Signal input 3 Signal input 4 Signal input 5 Signal input 6 Signal inputs 10 180 Ohm Sender...

Страница 11: ...11 EN CZone Signal Interface SI User Installation Manual 9 Dimensions Figure 9 Dimensions...

Страница 12: ...CABLE GLAND for ZONE SI BK SILICON 80 911 0036 00 ERM BLOCK MI 8 WAY PLUG 5mm PITCH 80 911 0043 00 11 EMC ratings IEC EN 60945 IEC EN 61000 FCC Class B ISO 7637 1 12V Passenger cars and light commerci...

Страница 13: ...13 EN CZone Signal Interface SI User Installation Manual 12 Declaration Of Conformity...

Отзывы: