MC-BUS SYSTEM CONNECTION

MC-Bus can provide the option of unified power control
for a Cyrus system from the Cyrus system amplifier. MC-
Bus connections are wired as a 'loop' with single RCA
phono interconnects. Instructions for MC-Bus connection
are included in the handbook for all Cyrus amplifiers with
MC-Bus connections.

OPERATION WITH MC-BUS CONNECTED

With MC-Bus installed, and the Cyrus aEQ7 connected as
recommended, Standby operation of the Cyrus aEQ7 will
be controlled by the system amplifier.

Cyrus aCA7, Cyrus Pre, Cyrus IIIi: When used with
these units in an MC-Bus loop, selecting the input
recommended will switch on the Cyrus aEQ7 from
Standby. This is the default factory setting.

Cyrus III,  AV master, MR3: To operate MC-Bus with
these units your Cyrus aEQ7 requires initialisation.
Set the Cyrus aEQ7 to Standby. Press the IEC key 

f

. and

hold it down for two seconds. The indicator above the IEC
key will flash once. The Cyrus aEQ7 will now recognise
MC-Bus commands from the Cyrus III, AV master and
MR3. Take the Cyrus aEQ7 in and out of Standby to
register this setting.
To restore normal operation, repeat this process. The IEC
indicator will flash twice. Remember to take the unit in
and out of Standby to register the new setting.

KNOW YOUR CYRUS aEQ7

Power Supply and Noise Performance
To minimise noise the Cyrus aEQ7 uses a special low-
leakage, fully shielded transformer. Specially designed to
minimise radiated mains harmonics, this transformer has
the lowest measured leakage Cyrus has ever achieved.

Additionally, to reduce Eddy currents a special slit-foil
screen shields the input circuitry from the mains supply.

Microcomputers, while offering convenience and ease of
use also radiate H.F. noise. Special opto-isolators in the
Cyrus aEQ7 fully isolate the internal microcomputer’s
digital signals from the sensitive analogue stages, reducing
coupled noise to negligible levels.

MC and MM Circuit Topology
MC and MM cartridges require completely different
circuit topologies. To match your cartridge characteristics
the Cyrus aEQ7 provides a dedicated input for each type.

Each input also has its own star earth to localise turntable
ground returns and improve common mode rejection.

Non Volatile Memory Storage
When you enter Standby, the Cyrus aEQ7 stores all its
settings as last used. These are recalled when the unit is
next used even if it has been switched off at the mains.

Note.  If you switch off at the mains without entering
Standby, new settings will not be stored. The unit will
retain the settings in use the last time Standby was entered.

Содержание aEQ7

Страница 1: ...User Instructions Cyrus aEQ7...

Страница 2: ...Cyrus aEQ7 English...

Страница 3: ...rtant Note Because of the very low levels of input signal please read the manuals accompanying your amplifier turntable tone arm and cartridge before installing the Cyrus aEQ7 You should always adhere...

Страница 4: ...unit on any surface which may hamper normal ventilation PRECAUTIONS REGARDING INSTALLATION Do not allow any liquids or foreign objects to fall into this unit When routing the power cord avoid running...

Страница 5: ...the PSX R to the 5 pin Cannon input socket of the Cyrus aEQ7 When correctly fitted the connector will latch into place in the socket No other connections or internal modifications to the Cyrus aEQ7 a...

Страница 6: ...a shorting plug into the left and right inputs of the unused inputs Note These shorting plugs must only be used as described above They should not be confused with regular phono plugs MOVING MAGNET MM...

Страница 7: ...u are unsure of your cartridge type we suggest you connect it into the MM input Note Connecting a MM type cartridge to the MC sockets will overload the input and may damage your amplifier and loudspea...

Страница 8: ...key e to select the appropriate input The red indicator above the key will turn on PLAYBACK EQUALISATION With the Cyrus aEQ7 you can select the traditional RIAA response or the newer IEC curve Press...

Страница 9: ...ice Remember to take the unit in and out of Standby to register the new setting KNOW YOUR CYRUS aEQ7 Power Supply and Noise Performance To minimise noise the Cyrus aEQ7 uses a special low leakage full...

Страница 10: ...be worth the investment Never extend tone arm leads Doing so can cause poor H F response hum and noise TURNTABLE AND AMPLIFIER GROUNDING The grounding of modern cartridges and tone arms is straight f...

Страница 11: ...ier and speakers If your loudspeakers are fitted with protection fuses check that the fuse is intact Check the Balance Control is not at an extreme limit Try another interconnect cable between the Cyr...

Страница 12: ...1kHz 0 01 THD 120mV rms Output Headroom ref 5mV input 1kHz 27dB Channel Balance 0 2dB Crosstalk 20kHz 5mV input 90dB S N ratio ref 5mV input I P shorted Unweighted 78dBA A weighted 92dBA THD ref 5mV...

Страница 13: ...ough accident misuse wear and tear neglect or through incorrect installation adjustment or repair by unauthorised personnel ii Liability for damage or loss occurring in transit to or from the purchase...

Отзывы: