This manual covers the operation and setup of the Cypress Suprex RF (5000 Series) units.  Several 
configurations are available with different enclosure and antenna options.  

All of the units with the 5000 series part number will have the same operational functions and electrical 
connections.  

Features:

-- DES56 Encryption for secure communications
-- Units are factory configured as matched pairs, no field channel setting is required.
-- Service mode for setup and configuration.
--“Quiet” RF protocol to conserve bandwidth and power
-- Field configurable reader formats
-- Multifunction indicator for determining operational status of the unit
-- Auxiliary I/O connections available for Door/Gate/Panel status signaling.   

Electrical Specifications:

(Each Unit)

Supply Voltage

#

#

8-16VDC

Current

#

#

#

500mA

Radio Specifications:

Frequency

# #

#

900 MHz ISM band

Type 

##

#

#

Frequency Hopping Spread Spectrum

Transmit Power

#

#

100mW

Receive Sensitivity

##

-110 dBm

Interference Rejection

#

70dB

Antenna Options and typical range: 

Internal - Up to 500 feet  

#

(SPX-5501)

Dipole - up to 1 Mile  (SPX-5511)

Yagi - Up to 12,000 feet. (SPX-5531)

Distances given are typical line of sight.  Actual distance will vary depending upon terrain, RF environment, and 
height of antenna.

The units are shipped configured as a matched pair and are ready to plug in and operate.  

The RF units are capable of operating with multiple pairs of units in the same environment.  Units on different 
channels can operate in the same area with minimal interference to each other. Unit channel selection is made 
at the factory and no field settings are necessary.  Up to 8 pairs of units can operate in the same area.  A serial 
number sticker will be present on the unit to indicate the paired units.  Units matched as a pair will have the 
same serial number or other identification labels. 

Individual units should maintain a 24" separation distance from each other when installed in a central location.

SPX-5000 Series:

Cypress Suprex RF Series - Introduction

Содержание SPX-5500 Series

Страница 1: ...SPX 5500SS SPX 5500 Series RF 900Mhz Suprex Reader Operations Manual SPX 5511 pictured...

Страница 2: ...any interference received including interference that may cause undesired operation Overview The SPX 5500 series of RF Wireless solutions provide a wireless bridge from card readers with gates or door...

Страница 3: ...obed Rising Mag Tek Strobed Falling Edge Reserved F2F x ON Dip switch 4 is ON Enable Pullup resistors Dip switch 4 is OFF Disable Pullup resistors DIP Switch 1 ON Service Mode DIP Switch 1 OFF Quiet M...

Страница 4: ...N C R1 Com R1 N O Card Reader LED DC Power Supply SPX 5000 Series Central Quick Reference Typical Suprex Central Connections Suprex RF Central 1 2 3 4 5 6 7 8 Wiegand Wiegand No Filter Strobed Rising...

Страница 5: ...r 100mW Receive Sensitivity 110 dBm Interference Rejection 70dB Antenna Options and typical range Internal Up to 500 feet SPX 5501 Dipole up to 1 Mile SPX 5511 Yagi Up to 12 000 feet SPX 5531 Distance...

Страница 6: ...h Test 1 Connect any antennas if the unit has a removable type antenna such as a dipole or Yagi 2 Connect a suitable power supply to both units Each unit should be provided with 8 16 volts DC and appr...

Страница 7: ...NTRAL UNITS FLASHING BETWEEN RED GREEN The Central is not Receiving communication from the Remote Operating modes By setting DIP switch 1 to the ON position the unit is placed in Setup Config mode Whe...

Страница 8: ...tion of the antenna will determine what is referred to as the polarization of the signal Significant reduction in range can result if the units are not oriented with the same polarity See below Both C...

Страница 9: ...and is placed away from metal objects This orientation may reduce range The metal pole is placed between antenna and other unit and the antenna is close to metal Better improved range Antenna has lin...

Страница 10: ...ect as shown below These connections can be used to allow the Remote relay to operate a DOOR STRIKE GATE or other locking hardware Refer to following pages in this document for details of each I O ope...

Страница 11: ...ing nothing connected the associated output will be set to a high level When the input is set to 0 Volts Ground the input will activate its associated output All Accessory outputs are Open Collector t...

Страница 12: ...Cypress Suprex RF Series Relay Controls Suprex RF Central Relay 1 IN Input Signal Relay 1 N C Relay 1 Com Relay 1 N O Suprex RF Remote Contact Outputs...

Страница 13: ...Cypress Suprex RF Series Relay Controls Suprex RF Central Relay 2 IN Input Signal Relay 2 N C Relay 2 Com Relay 2 N O Suprex RF Remote Contact Outputs...

Страница 14: ...relay and monitors the condition of the communication link between the Central and Remote units Relay 3 is activated when power is applied and the communication link between the Central and Remote is...

Страница 15: ...Cypress Suprex RF Series Relay Controls Suprex RF Central Relay 4 N C Relay 4 Com Relay 4 N O Suprex RF Remote Contact Outputs Relay 4 IN Input Signal 5Volts DC Maximum...

Страница 16: ...Cypress Suprex RF Series Auxillary I O Suprex RF Central Suprex RF Remote Aux Output Signal AUX IN AUX OUT Aux Input Signal...

Отзывы: