MB2100-01A-E Single Port Embedded Emulator Debugger SPEED-BOX Operation Guide, Doc. # 002-05542 Rev. *A
12
Product Description
1.4.3
Small form connectors
When using a connector on the user system with an even smaller form than the SMA coaxial
connector provided with the product, it is recommended to use the following connector and matching
cables. The operation of this connector has been verified by Cypress. Take care because the
relationship between the cable length and maximum permissible communication speed applies
regardless of the cable specifications.
Table 1-5. Small form connectors and corresponding cables
Figure 1-3 shows an example of the connection configuration when using the connector described
above.
Figure 1-3. Using a small-form connector
In addition to the method described above, it is also possible to use a coupler and conversion
adapter to join the mini-connector cable to the standard included cable.
Item
Description
Manufacturer
Remarks
Connector
H.FL-R-SMT(01)
HIROSE ELECTRIC CO., LTD.
Coversion adapter
HRMP-H.FLJ(40)
HIROSE ELECTRIC CO., LTD.
Cable
H.FL-2LP-FHSB-A-(3000)
HIROSE ELECTRIC CO., LTD.
Cable length: 3m
Cable
H.FL-2LP-FHSB-A-(1500)
HIROSE ELECTRIC CO., LTD.
Cable length: 1.5m
Cable
H.FL-2LP-FHSB-A-(100)
HIROSE ELECTRIC CO., LTD.
Cable length: 10cm
1. Mount the H.FL-R-SMT(01) on the user system.
2. Connect the HRMP-H.FLJ(40) to the SPEED-BOX.
3.
Connect a H.FL-2LP-FHSB-A-(3000) or equivalent between the H.FL-R-SMT(01) on the user system and
the HRMP-H.FLJ(40) that is connected to the SPEED-BOX
.
H.FL-R-SMT (01)
HRMP-H.FLJ (40)
EXTRA
POWER
OPTION
MDI
USB
READY
ON
OFF
POWER
DEBUG I/F
SPEED-BOX
Single Port Embedded Emulator Debugger
MB2100-01A-E
MDI
User system
H.FL-2LP-FHSB-A-(3000), etc.
Be careful of bad connections because