Page of
9
16
C. Connecting the Base Unit to the access control panel
1. To properly connect Base Unit to control panel, 2 separate Wiegand ports must be available on the
panel.
2. On the HHR-6300 base, connect Data 0, Data 1, common ground, and LED Input to one of the available
Wiegand ports.
3. To power the Base Unit, connect an 8-16Vdc power supply, with a minimum of 300mA of current rating.
D. Testing the Handheld Reader-to-Base Unit connection
1. Be sure the Handheld Reader has been charged for at least 4 hours prior to testing.
2. Press the Power button on the Handheld Reader. Press the “In” gate selection button to test whether the
Reader is communicating with the Base Unit. The Reader's Red LED will illuminate, and its Blue LED
will blink continuously when the Reader is communicating with the Base Unit. The LED on Base Unit
will also flash green.
3. To simulate a valid badge read, temporarily connect a wire to the “LED In” and to a ground pin on the
Base Unit. While it is connected, the Handheld Reader’s Green LED will be lit and the vibrate motor
will be active.
4. To test the Handheld Reader’s relay control, press the Relay Control (Vend) button. The Reader will
briefly vibrate and the Base Unit will emit an audible click. Relay activity can also be tested with a
voltage meter set to continuity mode. Refer to relay voltage rating in the Specifications Table on pg.
3.
5. Test with a valid badge by presenting the badge to the Handheld Reader. If all connections to the panel
are made correctly, the Reader’s Green LED will illuminate and the Reader will vibrate.
Note:
If there is no direct line of sight, if obstacles are present, or if additional distance is needed between
the Base Unit and Handheld Reader, a Cypress Repeater unit is recommended. See pg. 16.