![Cypress DPX-7212 Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/cypress/dpx-7212/dpx-7212_user-manual_2705791003.webp)
©2005 Cypress Computer Systems,Inc. • www.cypressworld.com 3/30/05
Page 3
CENTRAL UNIT ONLY
Dip switch #5 is ON: Alternate IO Assignment
a.
Door Strike relay does NOT follow LED
(Auxiliary setting, will follow Digital Input #1)
b.
Alarm Relay and Digital Output #3 swap functions.
On
Off
1 2 3 4 5 6 7 8
NOT USED
ALL OFF
Switch
6 7 8
0
1 x
2 x
3 x x
4 x
5 x x
6 x x
7 x x x
Wiegand
Wiegand / No Filter
Strobed Rising Edge (MR-5)
Strobed Rising Edge (Dorado 644)
Strobed Rising (Mag-Tek)
Strobed Falling Edge
Reserved
Unsupervised F/2F
x = ON
All settings except Switch 5 are the
same for Central and Remote units.
DIP Switch Settings-
Quick Reference
DPX-7212
To gain access to the DIP Switch, Un-plug the WiFi Module by removing this screw.
“Factory Defaults” Strap
Switch
1 2 Strap
on off In
on on In
on off Out
on on Out
off .. Out
.. = Don’t care
Restoring Factory Defaults
(Only takes effect during power up)
Restore Duprex Defaults
Restore WiPort Defaults
Service Mode 1
Service Mode 2
Normal Operation