background image

CYUSBS234 QUICK START GUIDE

Step 9: USB–I2C Bridge Testing

•  Click the 

Write data

 button. Data gets written at the

  default EEPROM page address
•  Click the 

Read & verify data

 button. When the received 

  and transmitted data is identical, the ‘Data verification

  successful’ message appears at the bottom of the 

 window. The test proves successful data transfer with

  the I2C interface

9

Step 12: USB–SPI Bridge Testing

• Click the 

Write data

 button. Data gets written at the

  default EEPROM page address 
•  Click the 

Read & verify data

 button. When the received

  and transmitted data is identical, the ’Data verification

  successful’ message appears. The test proves successful

  data transfer with the SPI interface

12

11

Step 10: USB–SPI Bridge Configuration

•  Repeat step 6
•  Click the 

SCB

 tab. Select 

SPI

 from the drop-down menu

  and click the 

Program

 button. The 'Program succeeded’ 

  message appears. Click 

OK

 to continue 

•  Click the 

Disconnect

 button. Press the reset switch, SW3

  (refer to the figure in step 13). The board enumerates

  as an SPI bridge
•  Set jumpers J17, J19, J20, and J21 as shown above 

10

Step 13: CapSense Button

•  Touch the CapSense

®

 button B1, as shown in the figure. 

  The D7 LED glows to indicate that the button is sensed
•  Remove the finger from the B1 CapSense button and

  the LED turns OFF to indicate that the button is released

13

LED D7

SW3

Step 11: USB–SPI Test Utility

•  Run the USB Serial Test Utility from 

Start > All

  Programs > Cypress > CYUSBS234 DVK >
 USBSerialTestUtility

•  Change the Product ID to 0004 to match the default

  Cypress PID. The test utility lists the SPI interface

  available on the board. Click 

OK

 to continue

J17 J19 J21 J20