Test CY4531 CCG3 EVK Setup with the Default Configuration and Type-C Power Adapter
This section describes the steps to observe the behavior when the CY4531 CCG3 EVK with the default configuration
parameters is connected to a Type-C power adapter. The voltage measured manually at the output header J7 is
verified by using the
CY4500 EZ-PD Protocol Analyzer
1. Ensure that the CCG3 device of the CY4531 CCG3 EVK is programmed with the latest default binaries provided
webpage. As shown in
, ensure jumper J4 is set to 2-3 and jumper J3 is set to 1-2
positions.
2. Connect the Type-C power adapter (
used as reference in this example) to the CY4531
CCG3 EVK, as shown in
Connect a multimeter to power output header J7 of the CY4531 CCG3 EVK.
3. When the Apple Type-C power adapter is connected to the Type-C port of the CY4531 CCG3 EVK, the CCG3
device of the CY4531 CCG3 EVK will be able to establish a power contract with the power adapter, as it is
configured for custom PDOs supported by this Type-C power adapter. Due to this, the power adapter will provide
14.8V, which is the established power configuration. This can be verified by measuring the voltage on the power
output header J7 of the CCG baseboard using a multimeter. The output voltage on this header will be about
14.8V, which is the negotiated voltage supported by the Type-C power adapter.
Figure 13
.
CY4531 CCG3 EVK Connected to Type-C Power Adapter
4. This output voltage can also be verified using the
CY4500 EZ-PD Protocol Analyzer
Ensure that the latest version of the
CY4500 EZ-PD Protocol Analyzer
5. Disconnect all connections shown in
, and connect CY4500 EZ-PD Protocol Analyzer to the PC (USB
host) using a Micro-USB cable.
6. Connect the Type-C plug of the CY4500 EZ-PD Protocol Analyzer to the Type-C port of the CCG3 EVK.
7. Launch the EZ-PD Analyzer Utility from
Windows
>
All Programs
>
Cypress
>
EZ-PD Analyzer Utility
>
EZ-PD Analyzer Utility
and click on the
Start Capturing
traffic.